Lenze I51AE175F10010000S Inverter i510 Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze I51AE175F10010000S is a 0.75 kW (1.0 HP) frequency inverter belonging to the i510 series within the Lenze i500 product family. Designed as a compact drive module for control cabinet installation, it features an IP20 protection rating and operates across an input supply voltage range of 180 V AC to 264 V AC on either single-phase or three-phase 230 V AC power networks. The inverter delivers a rated output current of 4.0 A with an output voltage range of 0 to 230 V AC and output frequencies up to 599 Hz. Supporting linear V/f, square-law V/f, sensorless vector control (SLVC), and sensorless synchronous motor control (SLPSM), this unit provides precise motor speed regulation for induction and permanent magnet synchronous motors across conveyor systems, industrial pumps, fans, and packaging machinery.
Putting a replacement I51AE175F10010000S into service requires physical terminal connections and parameter synchronization with the machine controller. The drive features an integrated CANopen fieldbus interface alongside onboard I/O comprising 5 digital inputs, 1 digital output (50 mA), 1 relay output (250 V AC / 3 A), 1 multi-function analog input, and 1 analog output supporting 0-10 V, 0-20 mA, or 4-20 mA signals. Commissioning and setup are completed via the front Micro-USB port using Lenze EASY Starter software, or with optional modules including the i5MADK0000000S keypad, i5MADW0000000S WLAN module, or i5MADU0000000S USB module. Because a new spare unit does not contain plant-specific operating parameters, complete parameter restoration from a backup file or parameter extraction from a donor unit is necessary prior to motor operation, with technical support available through ABC Industrial Parts.
Drive operating status and fault conditions are monitored via three front panel status LEDs—RDY, CAN RUN, and CAN ERR—as well as status word registers and fault history logs accessible over fieldbus or diagnostic software. Active protection functions trigger specific error codes, including 0x2310 for overcurrent, 0x3210 for DC bus overvoltage, 0x3220 for DC bus undervoltage, 0x3130 for mains phase failure, and 0x8130 for CANopen bus off conditions. First-line field checks should verify supply voltage levels, motor insulation, output wiring connections, fieldbus baud rate configuration, and 120-ohm CAN termination resistors. Severe internal faults such as code 0x6100 reflect hardware board defects that are non-field-serviceable, where unit replacement or a tested exchange drive from ABC Industrial Parts represents the direct path back to full production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | I51AE175F10010000S |
| Model / Type | Inverter i510 |
| Product Family | i500 |
| Power Rating | 0.75 kW (1.0 HP) |
| Supply Voltage Range | 180 - 264 V AC |
| Nominal Supply Voltage | 230 V AC (1-phase / 3-phase) |
| Rated Output Current | 4.0 A |
| Output Voltage | 0 - 230 V AC |
| Output Frequency Range | 0 - 599 Hz |
| Switching Frequency | 8 kHz |
| Control Modes | V/f linear, V/f square-law, Sensorless Vector Control (SLVC), Sensorless Synchronous Motor Control (SLPSM) |
| Digital Inputs | 5 |
| Digital Outputs | 2 (1 digital 50 mA + 1 relay 250 V AC / 3 A) |
| Analog Inputs | 1 (0-10 V / 0-20 mA / 4-20 mA) |
| Analog Outputs | 1 (0-10 V / 0-20 mA / 4-20 mA) |
| Integrated Fieldbus | CANopen |
| Ingress Protection Rating | IP20 |
Programming and Configuration
Programming and parameterizing the Lenze I51AE175F10010000S frequency inverter is carried out using Lenze EASY Starter engineering software connected via the built-in Micro-USB port on the front of the unit. The software interface allows service technicians to configure motor nameplate parameters, adjust acceleration and deceleration ramps, map digital and analog I/O functions, set up current limit thresholds, and define network parameters for CANopen communication.
Local configuration without a PC can be accomplished using direct plug-in operator modules. The i5MADK0000000S display keypad provides direct menu access for parameter editing, while the i5MADW0000000S WLAN module and i5MADU0000000S USB module provide wireless or direct physical connections for field transfer and saving of complete drive parameter files.
When commissioning a replacement drive or clearing parameter data error code 0x6300, a valid parameter file must be transferred to the inverter memory. If checksum errors occur, loading factory default settings and downloading the application parameter set via Lenze EASY Starter re-establishes correct operating parameters.
Communication and System Integration
The Lenze I51AE175F10010000S includes an integrated CANopen fieldbus interface that connects directly into automated control networks driven by standard CANopen master controllers. The interface supports real-time control, status word telemetry, and remote parameterization via the CANopen object dictionary without requiring additional fieldbus option cards.
Network operation is visually indicated by the CAN RUN and CAN ERR status LEDs located on the front panel. A solid green CAN RUN LED confirms Operational network state, flashing green indicates Pre-Operational state, and a single flash represents Stopped state. The CAN ERR LED flashes red during bus warning conditions and turns solid red when the interface enters a Bus Off state.
Integrating the inverter into a CANopen network requires establishing the matching node ID and baud rate settings. Reliable network communications depend on correct two-wire bus cabling with grounded shield lines and proper 120-ohm termination resistors installed at both physical ends of the CAN bus trunk to prevent code 0x8130 communication faults.
Diagnostics and Status Indication
Operational status and diagnostic evaluation for the I51AE175F10010000S are monitored through front-panel diagnostic LEDs, internal status word readouts over CANopen, and an integrated error log accessible via Lenze EASY Starter software or the optional i5MADK0000000S keypad module.
The primary RDY (Ready) status LED provides bi-color visual feedback on unit status: flashing green indicates the drive is ready or inhibited, solid green confirms active motor operation, flashing red indicates an active warning limit, and solid red alerts to an active trip fault. An unlit RDY LED indicates that supply power is disconnected or an internal hardware failure has occurred.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| RDY (Ready) | Green/Red - Solid / Flashing / Off | Green flashing = drive ready / inhibited; Green solid = drive active / running; Red flashing = warning; Red solid = fault active; Off = power off / internal hardware defect |
| CAN RUN | Green - Solid / Flashing / Single flash | Green flashing = Pre-Operational state; Green solid = Operational state; Single flash = Stopped state |
| CAN ERR | Red - Solid / Flashing / Off | Red flashing = Bus error / warning limit reached; Red solid = Bus Off state; Off = No CAN error |
Replacement and Spare Part Considerations
When replacing a defective drive with the Lenze I51AE175F10010000S, verify that the replacement unit matches the exact part number. This ensures identity with the 0.75 kW power rating, 4.0 A output current capacity, 230 V AC input rating, and integrated CANopen hardware build.
A replacement drive cannot run the application directly out of the box. Machine-specific parameters defining acceleration times, motor ratings, I/O functions, and CANopen node identifiers must be loaded onto the replacement unit using Lenze EASY Starter software, a WLAN or USB module, or the i5MADK0000000S keypad before starting the motor.
Prior to powering up a replacement inverter, conduct basic electrical checks: measure incoming line voltage (180 to 264 V AC), inspect output wiring on motor phases U, V, and W, check for short circuits to earth, and verify that 120-ohm fieldbus termination resistors are installed on the CANopen network.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| 0x2310 | Overcurrent / Short Circuit | Output current exceeded instantaneous peak current threshold. | Short circuit or earth fault on motor cable, motor power too large for inverter, acceleration time set too short. | Check motor cable and insulation; check motor parameters; increase acceleration time; replace inverter if error persists with disconnected motor (internal output stage hardware fault). |
| 0x3210 | DC Bus Overvoltage | DC-bus voltage has exceeded the upper shutdown threshold. | Excessive regenerative energy during deceleration, deceleration ramp time too short, mains voltage too high. | Increase deceleration time; check supply voltage; install external brake module/resistor if supported. |
| 0x3220 | DC Bus Undervoltage | DC-bus voltage fell below the lower threshold limit. | Mains voltage failure, line voltage dip, supply phase missing, brief power interruption. | Check mains supply voltage; check fuses and wiring. |
| 0x3130 | Mains Phase Failure | One of the supply mains phases is missing or unbalanced. | Blown input fuse, loose terminal, supply phase imbalance. | Check supply line voltages and input wiring. |
| 0x4210 | Heatsink Overtemperature | Inverter power section / heatsink temperature limit exceeded. | Insufficient cooling / airflow, ambient temperature too high, cooling fan blocked or defective, dirty heatsink fins. | Clean heatsink, check cabinet ventilation, verify ambient temperature is within specifications. |
| 0x4310 | Motor Overtemperature | Motor temperature sensor or PTC thermistor detected excessive temperature. | Motor overload, continuous low-speed operation without external cooling, motor PTC sensor triggered. | Check motor load; allow motor to cool down; verify motor thermal protection parameter settings. |
| 0x2221 | Motor Phase Failure | Interrupted connection on motor output phase (U, V, W). | Motor cable disconnected, loose motor terminal connection, contactor open on output side. | Check motor wiring, terminal connections, and output contactor. |
| 0x6100 | Internal Hardware Fault | Internal control board or microcontroller hardware monitoring error. | Internal electronic circuit failure, corrupted internal firmware, hardware defect. | Internal hardware fault — non-field-serviceable. Cycle power; if fault persists, return unit for repair or replace inverter. |
| 0x6300 | Parameter Data Error | Internal parameter set or memory checksum invalid. | Power interruption during parameter saving, corrupted EEPROM. | Load factory default settings and restore parameters from backup. If error recurs, internal memory defect — replace unit. |
| 0x7121 | Motor Stall | Motor locked or stalled under load. | Excessive mechanical load, motor blocked, acceleration rate too steep. | Check mechanical drive train for blockage; adjust current limit or acceleration times. |
| 0x8130 | CANopen Bus Off | CANopen communication system bus entered Bus Off state. | Cable fault, incorrect baud rate, missing bus termination resistor, noise/EMC interference. | Check CAN bus cable, shield grounding, baud rate configuration, and 120-ohm termination resistors. |
Frequently Asked Questions
How do I back up and restore parameters on the Lenze I51AE175F10010000S inverter?
Parameter backup and restoration are performed using Lenze EASY Starter software connected to the front Micro-USB port, or by using plug-in hardware options including the i5MADK0000000S keypad, i5MADW0000000S WLAN module, or i5MADU0000000S USB module.
What power supply voltage is required for the Lenze I51AE175F10010000S?
The drive accepts a single-phase or three-phase nominal 230 V AC input supply with an operational line voltage range from 180 V AC to 264 V AC.
What visual status LED indicators are present on the front panel?
The front panel features three diagnostic LEDs: RDY (Ready/Fault indicator), CAN RUN (CANopen operational state indicator), and CAN ERR (CANopen bus error indicator).
What action should be taken if fault code 0x6100 is displayed?
Fault code 0x6100 indicates an internal hardware monitoring failure that cannot be serviced in the field. Power to the unit should be cycled; if the error remains after restarting, the drive module must be repaired or replaced.
Which motor control modes does the Lenze i510 inverter support?
The inverter supports linear V/f, square-law V/f, sensorless vector control (SLVC), and sensorless synchronous motor control (SLPSM) for asynchronous induction and permanent magnet synchronous motors.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.