Lenze EMB9351-E 9300 Series Brake Unit Module

New 
On request
Refurbished   
5 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 | Series: 9300 Series Drives

The Lenze EMB9351-E is an autonomous standard-design brake unit module belonging to the Lenze 9300 product family. Functioning as a brake chopper within variable frequency drive systems, it protects the common DC bus against overvoltage conditions caused by motor regeneration during active dynamic braking or rapid deceleration. The module operates across a wide DC voltage range from 270 V DC up to 775 V DC, delivering 3 kW continuous braking power and up to 19 kW peak power at a maximum braking current of 28.3 A.

Physical integration is made through dedicated power screw terminals for the DC link connections (+UG, -UG) and the external braking resistor terminals (RB1, RB2), alongside control terminal blocks for enable input signals and fault output evaluation. Putting a spare unit into service requires hardware threshold alignment using onboard DIP switches and configuration jumpers to match the system mains voltage and operating parameters. Selecting a matching external braking resistor with a minimum resistance of 27 Ohms is essential to safeguard internal switching components. ABC Industrial Parts provides technical support to ensure replacement units are configured correctly before powering up the drive system.

Diagnostic feedback is provided via dedicated front-panel LED indicators and an integrated relay output. The Ready / Voltage ON LED remains solid when DC bus power is present, the Brake / Active LED illuminates during energy discharge into the resistor, and the Fault / Overload / Overtemperature LED signals thermal overload or threshold failures. Before putting a replacement online, technicians should verify terminal polarities, confirm resistor ohmic resistance, and check that configuration switches match the failed module. When internal power transistor or logic faults occur, ABC Industrial Parts can supply tested replacement units to restore operations without delay.

Technical Specifications

ManufacturerLenze
Part numberEMB9351-E
Model / type9351 Standard Design
Component typeBrake Unit Module
Product family9300
Supply voltage range270 - 775 V DC
Continuous braking power3 kW
Peak braking power19 kW
Maximum peak braking current28.3 A
Minimum braking resistance27 Ohm

Programming and Configuration

The Lenze EMB9351-E uses onboard hardware DIP switches and configuration jumpers to establish precise voltage switching thresholds. These settings align the module's activation point with the system mains voltage and DC bus limits.

Control wiring connects through dedicated terminal blocks, providing enable signal input and an integrated relay contact for fault signaling to a host controller or PLC. Because parameter selection relies on hardware jumpers rather than software file downloads, setting up a spare unit requires adjusting physical switches to match the replaced hardware.

Communication and System Integration

The module integrates directly into the drive DC link architecture via dedicated power terminals labeled +UG and -UG. Power output to the external braking resistor connects to terminals RB1 and RB2.

To ensure stable energy dissipation and system safety, the unit must be paired with an external braking resistor rated at a minimum resistance of 27 Ohms. Automated safety feedback is integrated via a dedicated relay contact that signals fault state directly to an upstream PLC or safety circuit.

Diagnostics and Status Indication

Status monitoring on the Lenze EMB9351-E relies on direct visual indicators on the front panel and fault signaling relay contacts. Three LED indicators provide real-time status of line supply presence, switching activity, and thermal or operational fault conditions.

Status LED Indicators

LEDColor/StatusMeaning
Ready / Voltage ONSolidDC bus voltage is connected and power supplies are operational
Brake / ActiveFlashing / ActiveBraking chopper transistor is actively discharging energy into the resistor
Fault / Overload / OvertemperatureSolidModule thermal overload or operational fault threshold exceeded

Replacement and Spare Part Considerations

When swapping a failed EMB9351-E brake unit, hardware configuration must be verified prior to energizing the DC bus. Inspect the positions of all onboard DIP switches and jumpers on the existing module to ensure identical voltage threshold settings on the replacement device.

Verify that the external braking resistor remains within specification and meets the 27 Ohm minimum resistance requirement. Confirm correct polarity on the DC link (+UG, -UG) terminals and secure terminal torque to prevent localized overheating during high-peak discharge cycles.

Frequently Asked Questions

What power rating does the Lenze EMB9351-E support?

The Lenze EMB9351-E provides 3 kW continuous braking power and up to 19 kW peak power with a maximum peak braking current of 28.3 A.

What is the minimum braking resistance required for the EMB9351-E?

The external braking resistor connected to terminals RB1 and RB2 must have a resistance of at least 27 Ohms.

How are activation thresholds configured on this module?

Activation thresholds are configured via physical onboard DIP switches and hardware jumpers to match the mains supply voltage of the drive system.

What DC supply voltage range is compatible with the EMB9351-E?

The module operates across a DC input voltage range from 270 V DC up to 775 V DC.

How does the EMB9351-E signal operational faults to a machine controller?

The module features an integrated relay contact output that provides fault evaluation signaling to an external PLC or control system.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.