Lenze 13051197 E82ZAFPC001 8200 Vector PROFIBUS-DP Module

New 
On request
Refurbished   
3 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector

The Lenze 13051197 E82ZAFPC001 is a dedicated PROFIBUS-DP communication function module engineered for fieldbus integration with Lenze 8200 vector frequency inverters and Lenze Drive PLC systems. Operating as a plug-in expansion module, this card fits directly into the Function Interface (FIF) front slot of the host drive, drawing power internally without requiring external power cables or secondary DIN-rail hardware. Although this module is discontinued by the manufacturer, it remains an essential component for automated speed and torque control in legacy material handling, packaging, textile, and automotive processing equipment.

Connecting the E82ZAFPC001 to a fieldbus network is established via an industry-standard 9-pin Sub-D female RS-485 connector. Commissioning a replacement unit involves setting the node address within the range of 1 to 125, which can be accomplished using the physical onboard DIP switches or remotely via drive parameter C0009. Transmission speeds from 9.6 kbit/s up to 12 Mbit/s are supported with automatic baud rate matching, while network integration on the master controller relies on the LENZ054B.GSD device master file. When replacing an existing module, maintenance personnel must ensure that the hardware address switches or software parameters are configured to match the master PLC project. Technical support for parameter extraction and spare preparation is available through ABC Industrial Parts.

Real-time visual diagnostic feedback is provided on the front interface by dual status LEDs labeled Ready / RUN and Fault / ERR. A solid green light signifies active operational communication, a flashing green light indicates initialization or readiness, and a solid red LED points to a communication error, failed baud rate search, or missing master. The unit reports specific host drive diagnostic codes including CE0 for FIF connection faults, CE1 for process data watchdog timeouts, CE2 for parameter channel failures, and CE3 for bus-off conditions. Initial troubleshooting should verify physical module seating in the FIF slot, check RS-485 wiring polarity, and review drive diagnostic parameter C0150 using Global Drive Control (GDC) software or an operating keypad module. Hardware-level internal failures require module replacement or tested exchange service from ABC Industrial Parts to restore production efficiently.

Technical Specifications

ManufacturerLenze
Part Number13051197
Model / TypeE82ZAFPC001
Component TypeCommunication Module
Product Family8200 vector
Communication ProtocolPROFIBUS-DP
Physical Interface9-pin Sub-D female (RS-485)
Baud Rate Range9.6 kbit/s to 12 Mbit/s (Automatic detection)
Bus Node Address Range1 to 125
Mounting LocationFunction Interface (FIF) slot
Lifecycle StatusDiscontinued

Programming and Configuration

Integration and parameterization of the Lenze E82ZAFPC001 module are performed using Lenze Global Drive Control (GDC) software or an attached drive operating module. The host PLC system requires the LENZ054B.GSD device master file to establish correct cyclic process data exchange and acyclic parameter transmission over PROFIBUS-DP.

Node address configuration offers dual options for installation flexibility. Technicians can set the network address physically using the onboard DIP switches or configure parameter C0009 via software. Process data watchdog supervision is managed through parameter C0088, which defines the monitoring time for communication loss detection.

Communication and System Integration

The E82ZAFPC001 acts as a PROFIBUS-DP slave device compliant with EN 50170 and IEC 61158 standards. It interfaces with the RS-485 network using a standard 9-pin Sub-D female connector, supporting transmission speeds from 9.6 kbit/s up to 12 Mbit/s with automatic speed adaptation.

Designed for seamless insertion into the modular Function Interface (FIF) slot on Lenze 8200 vector inverters and Drive PLCs, the module communicates directly across the drive internal interface. This design avoids external auxiliary power wiring and simplifies installation inside control cabinets.

Diagnostics and Status Indication

The front panel features dual LED indicators that provide immediate visual feedback regarding module power, network connection, and operational health. Further diagnostic analysis can be conducted by inspecting drive parameter C0150 via GDC software or an operating keypad module, as well as checking PROFIBUS network diagnostic telegrams sent to the master controller.

Status LED Indicators

LEDColor/StatusMeaning
Ready / RUNGreen - Solid / Flashing / OffGreen ON = Communication active / OPERATIONAL; Flashing = Initialization or ready; OFF = No supply voltage or fieldbus offline
Fault / ERRRed - Solid / Flashing / OffRed ON = Communication error, baud rate search failed, or master missing; Flashing = Configuration or parameterization error; OFF = Normal operation

Replacement and Spare Part Considerations

When swapping a damaged E82ZAFPC001 card, verify that the replacement unit is firmly seated in the drive FIF slot before restoring power. Node addressing must match the original configuration; check whether the previous card relied on physical DIP switch settings or parameter C0009.

Because this component is a legacy product, replacing it with an identical 13051197 card minimizes downtime by avoiding changes to the PLC hardware configuration or GSD device files. If communication fails upon installation, review parameter C0088 watchdog settings and inspect fieldbus cable termination.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0Communication Error 0Communication breakdown between host drive and E82ZAFPC001 module across the FIF interfaceModule mechanically loose, defective contact on FIF interface, electrical interference, or internal hardware faultCheck secure mechanical seating of module; inspect contacts; verify shield and ground connections; replace module if error persists
CE1Process Data Monitoring TimeoutPROFIBUS DP master stopped transmitting process data within watchdog timePROFIBUS network interruption, cable break, master stopped, or incorrect monitoring time setting in driveCheck PROFIBUS cabling and connectors; verify PLC master state; check parameter C0088 watchdog time
CE2Parameter Data Monitoring FaultFault during DP parameter data channel communicationInvalid parameter request from master, incorrect GSD file, or transmission errorVerify PLC program parameter access routines; check PROFIBUS configuration in master engineering tool
CE3PROFIBUS Bus Off / FaultModule detected excessive communication error count on RS-485 physical layerIncorrect bus termination, loose connector, wrong baud rate, damaged cable, or severe EMC interferenceInspect bus termination resistors at both ends of network segment; check wiring polarity (A/B lines); verify shield grounding

Frequently Asked Questions

Which drive series are compatible with the Lenze E82ZAFPC001 module?

The E82ZAFPC001 (part number 13051197) is designed for direct plug-in installation into the Function Interface (FIF) slot of Lenze 8200 vector frequency inverters and Lenze Drive PLC units.

How do I set the PROFIBUS node address on the E82ZAFPC001?

The node address (range 1 to 125) can be set physically using the onboard DIP switches on the module or configured via drive parameter C0009 using Global Drive Control (GDC) software or an operating keypad.

What GSD file is required for PLC configuration?

Master controller integration requires the LENZ054B.GSD device master file to establish PROFIBUS-DP communications.

What does a solid red Fault / ERR LED indicate?

A solid red light indicates a communication error, a failed baud rate search, or a missing master controller on the PROFIBUS network.

What causes error code CE0 on the drive?

Fault CE0 indicates a communication failure between the host drive and the E82ZAFPC001 module across the FIF interface, usually caused by a loose module, dirty interface contacts, or internal hardware issues.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.