Lenze 13168952 E82ZAFPC201 PROFIBUS-DP Communication Module
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13168952 E82ZAFPC201 is a fieldbus communication card engineered to connect host Lenze variable frequency drives into higher-level PROFIBUS-DP networks. Designed as a dedicated interface module for the Lenze 8200 vector and 8200 motec frequency inverter families, this unit operates as a PROFIBUS slave device. It allows a central programmable logic controller to perform high-speed cyclic data exchange, control drive function blocks, and monitor operating status across automated production equipment such as packaging lines, material handling systems, and textile machinery.
Mechanical installation relies on a compact snap-in form factor that mounts directly into the front function module slot of the 8200 drive host, avoiding external mounting hardware. System integration in PLC engineering platforms like Siemens STEP 7 or TIA Portal is achieved using a standardized GSD configuration file. Station addressing can be assigned via onboard hardware DIP switches or configured using internal drive parameters. Because operational drive parameters are retained within the host inverter's non-volatile memory, replacing a module requires restoring network addresses rather than reprogramming motor parameter sets. Service teams working with ABC Industrial Parts can rely on this modular design to minimize system downtime during drive interface replacement.
Real-time operation and bus integrity are reported directly through the module's onboard BUS / STAT status LED. This visual indicator signals active PROFIBUS data transfer, normal slave communication, and fault conditions such as a lost master or bus line error. First-line field checks should verify physical cabling, bus line length limits up to 1200 meters per segment, and hardware address DIP switch positions. When communication failures stem from internal electronic degradation on the card or host inverter interface, replacing the module with a tested spare from ABC Industrial Parts offers a fast path to restore full fieldbus communication.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13168952 |
| Model / Type | E82ZAFPC201 |
| Component Type | Fieldbus Communication Module |
| Product Family | Lenze 8200 Vector / 8200 Motec |
| Fieldbus Protocol | PROFIBUS-DP |
| Fieldbus Role | Slave |
| Maximum Bus Segment Length | 1200 m |
| Mounting Style | Front function module slot |
| Address Configuration | DIP switches or drive parameters |
Programming and Configuration
Integrating the Lenze E82ZAFPC201 communication module into a master control architecture requires importing the corresponding Lenze PROFIBUS GSD file into the engineering environment, such as Siemens STEP 7 or TIA Portal. The GSD file defines the module's I/O data structure, enabling cyclic process data mapping between the controller and the host 8200 vector or 8200 motec frequency inverter.
Hardware station addresses are configured directly via the onboard DIP switches located on the module or through internal drive parameter settings. Because drive control parameters are stored in the host inverter's non-volatile memory, swap-out replacement of the module does not clear motor profiles or application control settings, allowing rapid recommissioning once network parameters match.
Communication and System Integration
Operating as a standard PROFIBUS-DP slave device, the E82ZAFPC201 module establishes cyclic data exchange with central PLCs across automated production environments. It supports transmission distances up to 1200 meters per bus segment, depending on the network baud rate and fieldbus cable specifications used in the installation topology.
The direct plug-in design fits cleanly into the front function slot of Lenze 8200 vector and 8200 motec inverters, providing a structured fieldbus interface without requiring additional external power supplies or separate controller gateways.
Diagnostics and Status Indication
System health and communication activity are monitored using the integrated BUS / STAT LED located on the module faceplate. Solid and blinking lighting states provide instant visual feedback regarding active PROFIBUS data exchange, network synchronization, loss of master communication, or localized fieldbus cabling faults.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| BUS / STAT | Solid / Blinking | Indicates PROFIBUS communication state, data exchange status, and bus errors. Red or blinking states indicate bus communication faults or lost master. |
Replacement and Spare Part Considerations
Before installing or removing the Lenze 13168952 E82ZAFPC201 module, the host 8200 series drive must be completely powered down and isolated from mains supply. Inserting or unplugging the card while power is applied can lead to electrical damage to the communication board or host inverter logic interface.
When swapping a failed card with a spare unit, technicians must ensure the hardware DIP switches on the new module are aligned with the original node address settings. Once plugged into the front function slot and powered up, the replacement module reads the retained network parameters from the drive's non-volatile memory to resume fieldbus communications.
Frequently Asked Questions
Which drive series are compatible with the Lenze 13168952 E82ZAFPC201 module?
The E82ZAFPC201 communication card is designed for direct snap-in installation into the front function module slot of Lenze 8200 vector and Lenze 8200 motec frequency inverters.
How is the PROFIBUS station address set on the E82ZAFPC201?
The station address can be established using the onboard hardware DIP switches located on the module or through parameter settings inside the host drive.
Which software environments are used to configure the module in a PLC project?
The module is integrated into PLC configuration platforms, such as Siemens STEP 7 or TIA Portal, by importing the dedicated Lenze PROFIBUS GSD file.
What primary safety precaution must be taken before replacing the module?
The host 8200 drive must be fully powered down before removing or installing the module to prevent electrical damage to the interface card and drive electronics.
What is the maximum supported bus segment length for this module?
The module supports PROFIBUS-DP segment lengths up to 1200 meters, depending on selected network baud rates and cable specifications.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.