Lenze 33.8201BB 8200 Series 0.5HP 230V AC Frequency Inverter

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Series | Series: 8200 Series

The Lenze 33.8201BB is a 0.5 HP (0.37 kW) AC frequency inverter drive belonging to the Lenze 8200 series. Designed to operate on a 230 V AC supply across an acceptable line voltage window of 180 to 264 V AC, this compact drive delivers up to 2.4 A continuous output current to speed-regulated AC motors. Operating at an 8 kHz switching frequency, it supports an adjustable output frequency spectrum from 0 to 480 Hz across both standard open-loop V/f characteristic control and high-performance sensorless vector control modes. It is frequently employed across material handling, packaging machinery, fluid processing, and textile manufacturing equipment to provide dynamic torque and flexible velocity control.

Connecting and commissioning a replacement unit requires matching terminal wiring and option module configurations. The base unit features built-in control terminals providing four configurable digital inputs, one digital output, and one analog input supporting 0–10 V, 0–20 mA, or 4–20 mA signals. Network connectivity is established via an option slot that accommodates plug-in fieldbus modules for PROFIBUS-DP, CANopen, InterBus, or LECOM serial communication using an EMF2102IB converter. Because a replacement drive will not run off-the-shelf, technicians must reload motor parameters and drive settings into the unit's non-volatile EEPROM storage using an EMZ2101 or EMZ2102 operating keypad or Global Drive Control (GDC) PC software. When parameter extraction from a faulty donor unit is necessary, ABC Industrial Parts can assist in preparing replacement hardware prior to installation.

Diagnostic conditions are indicated directly through front status LEDs and digital interfaces. A solid or flashing green LED signals drive readiness and normal operation or controller inhibition, whereas a solid red LED indicates an active fault trip. Detailed trip logs and real-time parameters are accessible via the 7-segment keypad display or the GDC diagnostic window, displaying fault codes such as overcurrent (OC1, OC2, OC5), bus overvoltage (OU), undervoltage (LU), or motor overtemperature (OH4). First-line troubleshooting should verify mains supply stability, phase wiring, ramp settings, and fieldbus option card seating. If memory faults like EE or EER persist after a parameter reload, internal hardware failure is indicated, making a tested replacement or repair unit through ABC Industrial Parts the most efficient path back to operational status.

Technical Specifications

ManufacturerLenze
Part Number33.8201BB
Model / Type0.5HP 230V AC Frequency Inverter Drive
Product Series8200 Series
Component TypeFrequency Inverter
Rated Power (kW)0.37 kW
Horsepower0.5 HP
Supply Voltage230 V AC
Supply Voltage Range180 - 264 V AC
Output Voltage230 V AC
Continuous Output Current2.4 A
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodV/f Characteristic Control / Vector Control
Digital Inputs4
Digital Outputs1
Analog Inputs1

Programming and Configuration

Configuring the Lenze 33.8201BB frequency inverter is accomplished using either the plug-in EMZ2101 or EMZ2102 keypad modules or Lenze Global Drive Control (GDC) software connected via a LECOM serial interface. Parameter sets are held within non-volatile internal EEPROM memory, which supports dual parameter set storage to accommodate alternate motor profiles or operational sequences within a single drive.

For field replacements, parameter cloning allows quick transfer of operational settings between drives. Using the plug-in keypad, parameters can be saved directly from an existing unit and uploaded into the spare drive, eliminating manual configuration steps. When using GDC PC software via an EMF2102IB converter, complete device projects can be saved, backed up, and restored across multiple units on the factory floor.

Communication and System Integration

System integration on the Lenze 33.8201BB is structured around a modular control terminal strip and an expansion slot for fieldbus integration. The integrated terminal strip provides four configurable digital inputs, one digital output, and one selectable analog input capable of receiving 0 to 10 V, 0 to 20 mA, or 4 to 20 mA control signals.

Higher-level control network integration is enabled through plug-in fieldbus communication modules that install directly into the front option slot. Supported protocol modules include PROFIBUS-DP, CANopen, InterBus, and LECOM serial communication. The drive uses standard parameter channels and fieldbus mapping, allowing seamless control commands, speed references, and diagnostic feedback to be transmitted over the industrial network.

Diagnostics and Status Indication

Real-time monitoring on the Lenze 33.8201BB is provided by status LEDs, a 7-segment operating keypad display, and remote software diagnostics. The green LED signals active operation or controller inhibit, while the red LED indicates a fault condition. Further diagnostic details, including historical fault memory and live parameter readouts, can be viewed through the Global Drive Control (GDC) software or the plug-in keypad interface.

Status LED Indicators

LEDColor/StatusMeaning
Green LEDGreen - Flashing / SolidOperational state / drive ready; flashes when controller is inhibited or running normally
Red LEDRed - SolidFault state / error trip active

Replacement and Spare Part Considerations

Although Lenze has officially discontinued the 8200 series drive family in favor of newer ranges such as the i510 and i550 cabinet inverters, direct replacements like the 33.8201BB remain critical for maintaining existing production lines without requiring extensive panel rewiring or PLC program modification.

When replacing an existing drive, technicians must ensure that installed communication option cards (such as PROFIBUS-DP or CANopen) are transferred to the spare unit's option slot. In addition, parameter backup and reload procedures must be executed via keypad or GDC software to mirror control mode settings (V/f or vector control), ramp times, terminal assignments, and motor thermal overload thresholds before restarting the machine.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / OvercurrentOvercurrent acceleration phaseShort circuit on motor phase, acceleration ramp time too short, motor improperly sizedCheck motor wiring and insulation, increase acceleration ramp time (C012)
OC2Short Circuit / OvercurrentOvercurrent deceleration phaseDeceleration ramp time too short, regenerative energy too highIncrease deceleration ramp time (C013), fit brake chopper/resistor if required
OC5Overcurrent at Constant SpeedOvercurrent detected during steady-state operationSudden load change, mechanical blockage, motor faultCheck mechanical load, motor, and line voltage
OUOvervoltage in DC BusIntermediate DC circuit voltage exceeds upper limit thresholdExcessive regenerative energy from motor, deceleration time too short, main voltage too highExtend deceleration time, check supply voltage, install braking module
LUUndervoltage in DC BusIntermediate DC circuit voltage dropped below thresholdMains voltage failure, input supply too low, phase missingCheck supply voltage, input fuses, and AC power connections
OHHeatsink OvertemperatureInverter heatsink temperature exceeds limitInadequate cooling, ambient temperature too high, fan failure, dirty heatsink finsClean heatsink, improve enclosure ventilation, check ambient temperature
OH4Motor OvertemperatureMotor thermal sensor tripped (PTC / thermal contact)Motor overloaded, cooling fan obstructed, continuous operation at low speedsCheck motor load, ensure sufficient motor cooling, check PTC connection
EEEEPROM Memory ErrorInternal EEPROM checksum error or parameter corruptionPower interruption during parameter write, internal EEPROM hardware faultReload factory default settings. If fault persists, internal hardware error — return unit for repair or replace unit.
EEREEPROM Read ErrorInverter cannot read internal memory settings upon startupCorrupted non-volatile memory or hardware defectPerform parameter reset or re-download configuration. If unresolvable, internal hardware fault — replace the unit.
PEMotor Phase FailurePhase monitoring detected imbalance or loss of motor output phaseBroken motor cable, wire disconnected, output phase missingCheck wiring from inverter output U/V/W to motor terminals
LPMotor Overload (I*t)Motor load integral monitoring threshold exceededMotor operated above continuous rated load for extended periodReduce motor load or select larger motor/inverter combination
CE0Communication ErrorCommunication breakdown on serial interface / system busCable disconnected, incorrect baud rate, option module fault or loose connectionCheck communication cable, module seating, and bus communication settings

Frequently Asked Questions

What software is required to configure the Lenze 33.8201BB frequency inverter?

The unit can be configured using Lenze Global Drive Control (GDC) PC software via an EMF2102IB converter or manually adjusted using plug-in operating keypad modules such as the EMZ2101 or EMZ2102.

Can parameters be copied directly between two 33.8201BB drives without a PC?

Yes, parameter sets saved into an EMZ keypad module can be copied directly into another drive base unit using the keypad parameter transfer function.

What causes an OC1 fault code on the Lenze 33.8201BB drive?

An OC1 code indicates overcurrent during the acceleration phase, usually caused by a short circuit in the motor wiring, an over-accelerated ramp time (parameter C012), or improper motor sizing.

What communication protocols are supported by the Lenze 33.8201BB?

The drive supports fieldbus expansion modules installed in its option slot, including PROFIBUS-DP, CANopen, InterBus, and LECOM serial communication.

What should be done if an EE or EER fault code appears on startup?

An EE or EER error indicates EEPROM parameter checksum or read failure. Try executing a factory parameter reset or reloading the program file; if the error persists, an internal hardware defect is present and the drive must be repaired or replaced.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.