Product Family: 8200 | Series: 8200

The Lenze 358056 frequency inverter, model designation 33.8201BB, is part of the Lenze 8200 series designed for variable speed control of standard three-phase AC induction motors. Operating with a rated power output of 0.37 kW (0.5 HP) and a continuous output current rating of 2.4 A, this motor drive accepts flexible supply configurations including single-phase 230 V AC and three-phase 230 V AC within an operating range of 180 V to 264 V AC. Built in an open IP20 enclosure suitable for control panel DIN rail or surface mounting, the unit utilizes V/f characteristic control with linear or quadratic profiles, delivering output frequencies from 0 Hz up to 480 Hz at a default switching frequency of 8 kHz.

For machine wiring and system integration, the unit provides four programmable digital inputs, one multi-range analog setpoint channel (0–10 V, 0–20 mA, or 4–20 mA), a digital status output, and a programmable fault relay for TRIP signaling. Putting a spare unit into service requires transferring configuration parameters, which can be accomplished using the removable EMZ2101 or E82ZBC operating keypad memory or via Lenze Global Drive Control (GDC) software. Commissioning a replacement unit involves matching optional snap-on fieldbus modules such as CANopen or PROFIBUS-DP and verifying input voltage line connections. When maintaining control cabinets with legacy components, technical support from ABC Industrial Parts helps ensure parameter transfer and hardware compatibility are managed accurately.

Local status diagnosis is provided by front-panel LEDs, including a solid green READY LED for normal operation and a red TRIP LED indicating fault conditions. Detailed error logs can be retrieved from parameter C0161 TRIP memory or viewed directly on an attached keypad display. Faults such as short circuits (OC1), ground faults (OC2), or DC bus overvoltage (OU) typically stem from motor wiring issues, excessive load, or short deceleration ramps. If internal hardware faults (H05) or EEPROM errors (EE0) occur on the control board, internal components are not field-serviceable, and sourcing a pre-tested replacement unit or repair through ABC Industrial Parts provides the fastest path to restore operations.

Technical Specifications

ManufacturerLenze
Part Number358056
Model / Type33.8201BB
Product Family8200
Component TypeFrequency Inverter
Rated Power0.37 kW
Supply Voltage230 V AC (1-phase / 3-phase)
Supply Voltage Range180 - 264 V AC
Rated Current2.4 A
Output Voltage3x 0 - 230 V AC
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodV/f Characteristic Control
Enclosure Protection RatingIP20
Optional Communication ProtocolsCANopen, PROFIBUS-DP, LECOM (RS232/RS485)

Programming and Configuration

Parameterization and commissioning of the Lenze 358056 drive are executed through Lenze Global Drive Control (GDC) engineering software or directly using the detachable EMZ2101 operating keypad. Operating parameters regulate essential drive functions including acceleration ramps (C0012), deceleration ramps (C0013), and V/f characteristic curve adjustments.

The optional plug-in operating keypad features built-in memory capable of backing up complete drive parameter sets. This feature allows technicians to copy configuration files from an operational unit and write them directly into a spare unit. Alternatively, GDC software enables offline project file storage, real-time monitoring, and complete parameter restoration across LECOM serial connections.

Communication and System Integration

The modular architecture of the Lenze 8200 platform supports flexible network integration through optional snap-on communication modules. The 358056 frequency inverter supports fieldbus cards for CANopen, PROFIBUS-DP, and Lenze LECOM (RS232/RS485) interface standards, allowing smooth integration into centralized PLC architectures.

On-board control interfaces include four programmable digital inputs and one multi-range analog setpoint input supporting 0–10 V, 0–20 mA, and 4–20 mA modes. System status outputs include a digital transistor output alongside a dedicated programmable TRIP relay contact for signaling fault states to external control systems.

Diagnostics and Status Indication

Local operational state indication on the Lenze 358056 is provided by two front-panel LED indicators. A solid green READY LED confirms power supply and normal operational status, while a solid or flashing red TRIP LED highlights active system faults or shutdown conditions.

Detailed troubleshooting is supported through the EMZ2101 keypad display or software diagnostic tools. The drive maintains a history buffer in parameter code C0161, recording recent TRIP fault codes to assist technicians in diagnosing intermittent supply dips, thermal overloads, or network timeouts.

Status LED Indicators

LEDColor/StatusMeaning
READYGreen - SolidOperation / Ready state indicator
TRIPRed - Solid / FlashingTRIP active / Fault indication

Replacement and Spare Part Considerations

When installing a replacement Lenze 358056 (33.8201BB) inverter into an existing control cabinet, form factor and line supply requirements must be confirmed. The IP20 chassis design matches the standard physical mounting and terminal locations of the Lenze 8200 series. Line supply connections must be checked to ensure input voltage remains within the allowed 180 V to 264 V AC range for 1-phase or 3-phase systems.

To avoid operational mismatch, identical parameter values must be loaded into the spare drive prior to driving the AC motor. Parameters can be rapidly cloned from an existing drive using the plug-in keypad memory or downloaded from a saved GDC project file. If the original installation utilizes fieldbus communications (such as CANopen or PROFIBUS-DP), the snap-on communication module from the original drive must be seated securely onto the replacement unit.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit on output motor terminals or internal transistor switch fault.Short circuit in motor winding or motor cable, severe capacitive leakage, internal drive power stage short.Check motor cable and winding insulation. If fault occurs immediately upon power up without motor connected, internal power module is defective requiring drive replacement or repair.
OC2Earth FaultGround fault / Earth fault detected on output phase.Motor winding grounded to frame, damaged motor cable insulation, excessive cable length.Check motor and wiring with megohmmeter. Replace defective wiring or motor.
OC5Overload during AccelerationExcessive motor current draw during acceleration profile.Acceleration time too short, mechanical overload, motor stalled.Increase acceleration time (C0012), check mechanical drive train for binding.
OUDC Bus OvervoltageIntermediate circuit DC bus voltage exceeded upper limit.Regenerative energy from motor during deceleration too high, deceleration ramp too short, line supply voltage too high.Increase deceleration time ramp (C0013), fit external brake chopper / brake resistor if supported.
LUDC Bus UndervoltageIntermediate circuit DC bus voltage dropped below minimum threshold.Mains voltage supply failure, voltage dip, mains fuse blown, internal pre-charge circuit fault.Check main power line voltage supply, check input fuses and wiring.
OHHeatsink OvertemperatureDrive heatsink temperature exceeded upper thermal trip limit.Inadequate ventilation, clogged cooling fins, ambient temperature too high, fan failure.Clean heatsink cooling fins, improve panel ventilation, allow unit to cool.
OH4Motor OvertemperatureMotor thermal sensor input triggered (PTC / thermal contact).Motor overloaded, insufficient motor cooling at low speeds.Allow motor to cool down, reduce load or check forced cooling fan.
CE0Communication ErrorInterruption in fieldbus / automation module communication.Loose cable, disconnected bus connector, baud rate mismatch, faulty communication module.Check fieldbus cable connections, termination resistors, and module seating.
EE0EEPROM FaultData corruption or read/write error in internal parameter memory.Electromagnetic interference during parameter write, hardware internal flash/EEPROM fault.Restore factory default settings and reload parameter set. If fault persists, hardware board failure requires replacement.
H05Internal Hardware ErrorInternal micro-controller or circuit fault detected during self-test.Internal component failure, control board fault.Internal hardware fault — power cycle unit. If problem persists, return unit for repair or replace.

Frequently Asked Questions

What power rating and input supply voltage does the Lenze 358056 support?

The Lenze 358056 (model 33.8201BB) has a rated power output of 0.37 kW (0.5 HP) and a continuous output current of 2.4 A. It accepts both single-phase and three-phase 230 V AC supply voltages within an operating range of 180 V to 264 V AC.

How are parameter settings transferred to a spare Lenze 358056 drive?

Parameters can be saved and transferred using the removable EMZ2101 or E82ZBC operating keypad memory module. Alternatively, settings can be transferred over a LECOM connection using Lenze Global Drive Control (GDC) software.

Which fieldbus protocols can be integrated with the Lenze 8200 series inverter?

The Lenze 8200 modular series supports optional snap-on communication modules for PROFIBUS-DP, CANopen, and Lenze LECOM (RS232/RS485) network protocols.

What should be checked if the drive shows fault code OC1?

Fault code OC1 indicates a short circuit on the output terminals or an internal power stage fault. Check the motor cable and motor winding insulation. If the fault occurs immediately upon powering up without a motor connected, the internal power module is defective.

What do the front-panel LEDs indicate on the Lenze 358056?

A solid green READY LED indicates normal power and operational readiness. A solid or flashing red TRIP LED indicates an active TRIP fault condition.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.