Lenze E82ZAFCC – 8200 Series CAN/System Bus Function Module

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector | Series: 8200 series

The Lenze E82ZAFCC is a CAN and System Bus function module designed for Lenze 8200 vector and 8200 motec frequency inverters. Operating as a plug-in communication module, the unit mounts directly into the host drive's Function Module Interface (FIF) slot and receives its 5 V DC supply voltage internally from the drive. This communication module expands host drive capabilities, enabling real-time speed and position synchronization across distributed drives as well as centralized PLC control over fieldbus networks.

Connecting the E82ZAFCC to an active network is managed via a pluggable screw terminal strip featuring connections for CAN-H, CAN-L, and CAN-GND. Supporting communication speeds between 10 kbit/s and 500 kbit/s, the module implements both the standard CANopen DS301 profile and the high-speed Lenze System Bus protocol using CAN 2.0A. Commissioning a replacement unit requires configuring the onboard hardware DIP switches to match the original node ID and baud rate settings. Drive parameters and communication profiles can be transferred or verified using Lenze Global Drive Control software version 4.0 or higher or an optional Keypad XT unit, with technical assistance available through ABC Industrial Parts when re-establishing fieldbus integration.

Diagnostic feedback is provided on the front cover through two visual indicators: the green CAN RUN LED and the red CAN ERR LED. These LEDs display operational modes, communication warnings, or severe bus-off states, while system bus parameters C0359, C0361, and C0363 offer deeper diagnostic monitoring via software or keypad. Initial troubleshooting should verify CAN-H and CAN-L polarity, 120 Ohm bus line termination, supply stability, and DIP switch positions. If communication errors persist or the unit enters an unrecoverable Bus-Off state due to internal hardware failure, ABC Industrial Parts can supply a replacement or tested exchange module to restore machine operation quickly.

Technical Specifications

ManufacturerLenze
Part numberE82ZAFCC
Model / type8200 SERIES CAN/SYSTEM BUS FUNCTION MODULE
Product family8200 vector
Component typeCommunication Module
Supply voltage5 V DC (internal)
Baud rate range10 - 500 kbit/s
Supported protocolsCANopen (DS301), Lenze System Bus (CAN 2.0A)
Bus termination resistance120 Ohm
Connector typePluggable screw terminal strip
Host interface connectorFunction Module Interface (FIF)

Programming and Configuration

Software setup for the Lenze E82ZAFCC is handled using Lenze Global Drive Control (GDC) software version 4.0 or above, or locally using a Keypad XT (E82ZBC) module. Communication parameters, including response monitoring times for CAN process data objects, are adjusted under parameter registers C0357/1 through C0357/3.

Hardware configuration simplifies commissioning through integrated DIP switches located on the module. These switches allow technicians to set node addresses and baud rates without requiring software tools, enabling fast physical replacements during maintenance.

Communication and System Integration

The E82ZAFCC provides dual fieldbus communication capabilities, supporting both open CANopen (DS301 profile) and the Lenze System Bus (CAN 2.0A). Operating at selectable speeds from 10 kbit/s up to 500 kbit/s, it integrates 8200 vector and 8200 motec inverters into higher-level controller architectures or synchronized drive networks.

Physical wiring connects via a pluggable screw terminal block accommodating CAN-H, CAN-L, and CAN-GND lines. Correct network operation requires standard 120 Ohm bus termination resistors fitted at both line ends, maintaining a total line resistance of 60 Ohms across the bus.

Diagnostics and Status Indication

Status monitoring is available directly on the module's front cover via visual LED indicators. Additional diagnostic analysis can be performed through Lenze Global Drive Control software or Keypad XT by inspecting system bus parameters C0359, C0361, and C0363, or by using a external CANbus analyzer tool.

Status LED Indicators

LEDColor/StatusMeaning
CAN RUNGreen - Solid / Blinking / OffOff: Pre-operational / stop state. On: Operational status, regular CAN communication active. Blinking: Pre-operational state.
CAN ERRRed - Solid / Flashing / OffOff: No CAN communication error. Blinking: CAN warning limit reached or telegram error. On: CAN Bus-Off state or hardware communication failure.

Replacement and Spare Part Considerations

Replacing an existing E82ZAFCC module requires plugging the new unit into the host drive's Function Module Interface (FIF) slot. The pluggable screw terminal strip enables quick hardware swaps without disturbing existing network cables.

Before restoring power, ensure the onboard DIP switches on the spare unit are aligned with the target node address and baud rate settings. Verify that process data monitoring registers match the application requirements in Lenze GDC software to ensure seamless fieldbus synchronization.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0CAN bus communication fault (Time-out)Communication failure on the Lenze System Bus (CAN). No process data received within configured monitoring time.Bus cable broken or disconnected, incorrect baud rate, incorrect node address, slave not power-supplied, terminating resistors missing.Check bus cable connections and shielding, verify matching baud rate on all nodes, verify DIP switch settings, check 120 Ohm termination resistors at line ends.
CE1CAN-In1 monitoring time exceededProcess data object CAN-In1 was not received within the response time limit set in C0357/1.Master controller stopped transmitting CAN-In1 PDO, network overload, master cycle time too slow.Check master controller run status, check PLC cycle time and PDO transmission timing, check CAN connection.
CE2CAN-In2 monitoring time exceededProcess data object CAN-In2 was not received within the response time limit set in C0357/2.Master controller failed to transmit CAN-In2 frame, fieldbus interruption.Verify host PLC process data configuration and cyclic transmission settings.
CE3CAN-In3 monitoring time exceededProcess data object CAN-In3 was not received within the response time limit set in C0357/3.Transmission interruption for process data object CAN-In3.Check transmitter node configuration and cabling.
CE4System bus (CAN) Bus-Off stateThe CAN controller went into Bus-Off state due to excessive transmission or reception error counters.Extremely high electromagnetic interference (EMC), inverted signal lines (CAN-H and CAN-L swapped), missing or duplicate termination resistors, mismatch in baud rate.Check CAN-H and CAN-L wire polarity, ensure correct grounding/shielding, check termination resistance (60 Ohm total across bus line), reset fault on inverter. If persistent with correct wiring, internal hardware failure — replace the module.

Frequently Asked Questions

What drives are compatible with the Lenze E82ZAFCC function module?

The E82ZAFCC module is designed to plug directly into Lenze 8200 vector frequency inverters and Lenze 8200 motec motor-mounted drives via the Function Module Interface (FIF) slot.

How do I configure the node ID and baud rate on the E82ZAFCC?

Node addressing and baud rate selection can be set directly using the onboard hardware DIP switches on the module, allowing for hardware setup without software tools.

What software is used to parameterize the E82ZAFCC module?

Parameters can be configured using Lenze Global Drive Control (GDC) software version 4.0 or higher, or locally using a Keypad XT (E82ZBC) terminal.

What protocols does the E82ZAFCC support?

The module supports both the standard open CANopen (DS301 profile) and the Lenze System Bus protocol based on CAN 2.0A, operating at speeds from 10 kbit/s to 500 kbit/s.

What does a solid red CAN ERR LED indicate?

A solid red CAN ERR LED indicates that the module has entered a CAN Bus-Off state or is experiencing an internal hardware communication failure.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.