Lenze E82ZAFCC001 System Bus (CAN) Function Module

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Vector | Series: E82EV

The Lenze E82ZAFCC001 is a System Bus (CAN) communication function module engineered for Lenze 8200 Vector frequency inverters, including the E82EV series. Designed as a direct plug-in module for the inverter's dedicated Function Interface (FIF) slot, this device receives internal auxiliary power directly from the host drive controller without requiring external power supplies. Compliant with the ISO 11898 standard, it enables high-speed communication across drive networks using both standard CANopen fieldbus profiles and the proprietary Lenze System Bus protocol.

Fieldbus wiring is established through a removable, pluggable screw terminal block providing connection points for CANL, CANH, and CAN_GND lines. Commissioning a replacement unit requires setting the integrated hardware DIP switches located directly on the module, which determine both the node address (ranging from 1 to 63) and the operational transmission speed between 10 kbit/s and 500 kbit/s. Because network operation relies on exact node identification and baud rate alignment, technicians must ensure the replacement DIP switch positions match the failed unit prior to inserting it into the drive's FIF slot.

Real-time operational feedback is provided via front-panel RUN and ERR status LEDs, which signal bus activity, pre-operational states, warning limits, or bus-off conditions. Further diagnostic insight can be extracted through drive parameter C0359 using Lenze Global Drive Control (GDC) software or a connected XT E82ZBC keypad. Initial troubleshooting steps should verify cable termination with 120 Ohm resistors, proper shield grounding, correct DIP switch configuration, and firm seating of the module header. If internal hardware faults occur, ABC Industrial Parts provides tested replacement units and repair options to help restore production lines efficiently.

Technical Specifications

ManufacturerLenze
Part NumberE82ZAFCC001
Model / TypeSystem Bus (CAN) Function Module
Product Family8200 Vector (E82EV Series)
Component TypeCommunication Module
Supported ProtocolsLenze System Bus (CAN ISO 11898), CANopen
Supported Baud Rates10, 20, 50, 100, 125, 250, 500 kbit/s
Maximum Bus Nodes63
Power SupplyInternal via drive controller FIF slot
Drive InterfaceFIF (Function Interface) slot plug-in header
Fieldbus ConnectorPluggable screw terminal block (CAN_L, CAN_H, CAN_GND)

Programming and Configuration

Configuring the Lenze E82ZAFCC001 involves both hardware setup and drive parameterization. Basic network identity is established via on-board DIP switches, which define the node address from 1 to 63 and select one of seven supported transmission speeds (10, 20, 50, 100, 125, 250, or 500 kbit/s). This hardware configuration allows fast setup directly at the machine without pre-programming tools.

For full system integration and online diagnostics, the module operates in conjunction with Lenze Global Drive Control (GDC) software or the local XT E82ZBC keypad. Drive parameter C0359 provides system bus diagnostic information, allowing technicians to verify communication states, monitor receive and transmit channels, and adjust monitoring times for transmit Process Data Objects (PDOs).

Communication and System Integration

The E82ZAFCC001 module brings standardized CANopen and Lenze System Bus connectivity to the 8200 Vector drive family in accordance with ISO 11898. It allows multi-drive synchronization, master-slave communication in automated production lines, and remote drive parameterization from PLC automation systems.

Physical bus connections are completed using a pluggable screw terminal block with dedicated terminals for CANL, CANH, and CAN_GND. Up to 63 nodes can participate on a single bus segment, provided that appropriate EMC shielding precautions are followed and 120 Ohm termination resistors are installed at both physical ends of the CAN network.

Diagnostics and Status Indication

The front panel features two status LEDs—RUN (Green) and ERR (Red)—that deliver immediate visual diagnostics. A solid green light indicates normal bus operation, while a blinking green light signals a pre-operational or initializing state. A red LED indicates a bus error, warning limit detection, or a Bus-Off state, with continuous red light highlighting serious hardware faults or unrecoverable communication failures.

Advanced diagnostic monitoring is available online through Lenze Global Drive Control (GDC) or via the drive's diagnostic parameters. In particular, diagnostic code C0359 aids in isolating communication timeouts on individual CAN channels or detecting buffer overruns before they interrupt machine operation.

Status LED Indicators

LEDColor/StatusMeaning
CAN-RUN / RUNGreen - Solid or BlinkingSolid green indicates normal operational bus state; blinking indicates pre-operational or initializing state.
CAN-ERR / ERRRed - Solid or FlashingRed LED indicates bus error, warning limit reached, or Bus-Off state. Continuous light indicates hardware fault or severe error.

Replacement and Spare Part Considerations

When replacing a Lenze E82ZAFCC001 communication module in an 8200 Vector inverter, ensure that power to the frequency inverter is turned off before plugging the module into or removing it from the Function Interface (FIF) slot. Hardware configuration switches must be transferred identically from the original module to the replacement to ensure the new module assumes the correct node address (1-63) and baud rate (10-500 kbit/s) on the CAN network.

Field wiring must be transferred to the replacement module's pluggable screw terminal, ensuring CANL, CANH, and CAN_GND conductors are correctly placed and the cable shield is grounded according to EMC guidelines. If communication errors such as CE0 or CE2 persist after setting switches and verifying network termination resistors (120 Ohm), ABC Industrial Parts can assist with tested replacement modules or repair services to restore reliable operation.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0Communication Error 0 (System Bus / CAN-In1)Communication failure or telegram timeout on CAN System bus channel 1.Bus interruption, incorrect baud rate, wrong node address, missing termination resistor, or module fault.Check CAN wiring, shield grounding, termination resistors (120 Ohm), DIP switch settings, and module insertion. If fault persists on known-good bus, replace module.
CE1Communication Error 1 (System Bus / CAN-In2)Communication error or monitoring timeout on CAN System bus channel 2.Master failed to transmit PDOs within configured monitoring time (time-out).Verify master transmit rate and cycle time settings; check fieldbus connection.
CE2Communication Error 2 (CAN Bus Off)CAN controller reached Bus-Off error state due to excessive transmission/reception errors.Severe noise interference, bad shielding, mismatched baud rates, or hardware failure on module.Check shielding, EMC precautions, termination resistors. If hardware fault is indicated, replace E82ZAFCC001 module.
CE3Communication Error 3 (System Bus / CAN-In3)Telegram monitoring time elapsed on CAN channel 3.Interrupted message transmission from CAN master/peer.Check network master status and cable connection.
CE4Communication Warning / Fault (CAN FIFO Overflow)Internal CAN receive buffer overflow.Excessive bus load or drive processing overload.Reduce CAN bus baud rate or optimize transmit task timings.

Frequently Asked Questions

How are the node address and baud rate configured on the Lenze E82ZAFCC001?

Hardware DIP switches located directly on the module are used to configure the node address (1 to 63) and select the desired communication speed (10, 20, 50, 100, 125, 250, or 500 kbit/s) without needing external software tools.

Which frequency inverters are compatible with the E82ZAFCC001 module?

The module is designed specifically for Lenze 8200 Vector series frequency inverters (E82EV series) and plugs into the drive's Function Interface (FIF) slot.

Does the E82ZAFCC001 require an external auxiliary power supply?

No, the module receives internal operating power directly through the inverter's Function Interface (FIF) slot header.

How can I monitor diagnostic status for the E82ZAFCC001?

Diagnostic status is indicated by front-panel RUN (Green) and ERR (Red) LEDs, drive diagnostic code C0359, or online through Lenze Global Drive Control (GDC) software and the XT E82ZBC keypad.

What does error code CE2 indicate on an 8200 Vector drive?

CE2 indicates a CAN Bus Off condition caused by excessive transmission or reception errors. Common causes include electrical noise, poor shielding, mismatched baud rates, or module hardware failure.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.