Lenze EMF2111IB 2111IB INTERBUS Fieldbus Module

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

The Lenze EMF2111IB is a plug-in fieldbus communication module from the 2100 Series Fieldbus Modules, engineered to integrate Lenze 8200 vector frequency inverters and Lenze 9300 servo drives into centralized INTERBUS network architectures. Functioning as the primary interface between host drive controllers and master PLCs, this module, model 2111IB, handles rapid data exchange in industrial environments such as automotive manufacturing, material handling, packaging machinery, and textile production. Built with dual 9-pin D-Sub connectors and powered by a dedicated 24 V DC auxiliary input, the module inserts directly into the function module slot of compatible drive units to establish real-time fieldbus communication at a fixed transmission rate of 500 kbaud.

Physical integration is achieved using standard RS-422 differential transmission through a 9-pin D-Sub male connector for the incoming remote bus and a 9-pin D-Sub female connector for the outgoing segment. Commissioning a replacement unit requires configuring physical hardware DIP switches on the module to establish proper bus addressing and matching the network profile, alongside parameter alignment within the host drive using Lenze Global Drive Control (GDC) or Phoenix Contact INTERBUS CMD software. The module processes up to 4 cyclic process data words alongside a PCP 2.0 parameter channel compliant with DriveCOM Profile 21 standards. Because the unit features an external 24 V DC auxiliary supply connection operating between 18 V DC and 32 V DC, network loop continuity across the fieldbus is maintained even when the main power to the host drive is removed. When replacing an existing module, sourcing a pre-tested spare from ABC Industrial Parts helps ensure rapid restoration without risking fieldbus segment interruption.

Diagnostic feedback is provided locally through four onboard LEDs—Bus Active (BA), Remote Bus Disabled (RD), Transmit/Receive (TR), and Fiber Optic/Cable Check Fault (FO)—which indicate bus traffic, PCP channel processing, and cabling errors. System-level monitoring is supported by checking drive parameter codes C0150 and C0591 or reading the master controller's INTERBUS diagnostic register. Fault conditions such as communication loss (CE0 / E08), process data time-out (CE1), parameter access errors (CE2), or hardware initialization failure (CE3) point to specific issues like missing 24 V DC auxiliary power, misaligned DIP switches, damaged cables, or internal hardware faults. First-line troubleshooting should include verifying the auxiliary voltage supply, checking cable seating, and confirming DIP switch positions. If internal hardware corruption or connector damage prevents initialization, ABC Industrial Parts offers repair options and tested replacement units to restore machine uptime.

Technical Specifications

ManufacturerLenze
Part NumberEMF2111IB
Model / Type2111IB
Product Family2100 Series Fieldbus Modules
Component TypeCommunication Module
Communication ProtocolINTERBUS
Baud Rate500 kbit/s
Supply Voltage24 V DC
Supply Voltage Range18 - 32 V DC
Rated Current170 mA
Process Data Capacity4 words
Parameter ChannelPCP 2.0
Profile ComplianceDriveCOM Profile 21
Incoming Interface9-pin D-Sub male
Outgoing Interface9-pin D-Sub female
Lifecycle StatusDiscontinued

Programming and Configuration

Programming and commissioning the Lenze EMF2111IB module relies on physical hardware settings combined with host drive parameterization tools. Hardware DIP switches located on the module board define the primary fieldbus communication settings and bus addressing. Drive-level integration and monitoring are performed using Lenze Global Drive Control (GDC) software or Phoenix Contact INTERBUS CMD engineering software, allowing technicians to verify parameter settings and cyclic data assignments across the network.

The module handles up to 4 cyclic process data words (PCD) for real-time motion and control commands, working in parallel with a PCP 2.0 parameter channel. This structure operates in full compliance with DriveCOM Profile 21 standards. Fieldbus status and active error diagnostic codes are mapped to drive parameter codes C0150 and C0591 within the host drive, providing direct access to diagnostic information during commissioning and routine operation.

Communication and System Integration

The EMF2111IB fieldbus module establishes network connections using two standard 9-pin D-Sub connectors via RS-422 differential signals at a fixed transmission rate of 500 kbaud. A 9-pin D-Sub male connector accepts the incoming remote bus, while a 9-pin D-Sub female connector provides the signal loop out to the next node in the INTERBUS line topology.

To preserve fieldbus ring integrity across complex automation setups, the module incorporates a dedicated 24 V DC auxiliary power connection rated for an operational range of 18 V DC to 32 V DC at 170 mA. This independent power path ensures that the incoming and outgoing remote bus signals continue looping across the panel even if the local host drive is shut down or undergoes maintenance.

Diagnostics and Status Indication

Real-time operational monitoring is provided by four front-panel diagnostic LEDs. The green BA LED indicates an active INTERBUS connection with established cyclic data exchange. The red RD LED highlights an inactive or disconnected outgoing remote bus segment. The flashing green/yellow TR LED indicates active parameter and control transmission over the PCP channel, while the yellow/red FO LED alerts operators to signal quality degradation or wiring faults on the incoming INTERBUS cable segment.

For elevated diagnostic analysis, host drive parameter codes C0150 and C0591 report exact communication states and active fault conditions. Diagnostic data can also be queried directly at the main PLC controller by accessing the INTERBUS diagnostic register, enabling fast localization of bus intermissions without secondary test equipment.

Status LED Indicators

LEDColor/StatusMeaning
BA (Bus Active)Green - SolidINTERBUS bus active and cyclic data transfer established
RD (Remote Bus Disabled)Red - SolidOutgoing remote bus interface is switched off or disconnected
TR (Transmit/Receive / Redundancy)Green/Yellow - FlashingControl or parameter data processing active via PCP channel
FO (Fiber Optic / Cable Check / Fault)Yellow/Red - Solid/FlashingQuality error or interruption detected on incoming INTERBUS cable segment

Replacement and Spare Part Considerations

When replacing an EMF2111IB module, maintenance personnel must confirm that the replacement unit shares the exact 500 kbaud fixed transmission rating and DIP switch setting structure. Because the module interacts directly with Lenze 8200 vector and 9300 servo drives, physical alignment with the drive's function slot and pin integrity must be verified before applying power.

Ensure the DIP switch positions on the replacement module are matched exactly to the original unit prior to installation to ensure immediate recognition by the INTERBUS master controller. Reconnect the external 24 V DC auxiliary supply wires to terminal points prior to powering up the system, verifying continuous remote bus looping across the network segment.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0 / E08Communication Error 0 / Interbus FaultCommunication failure between host drive controller and EMF2111IB INTERBUS module, or bus connection interrupted.Module disconnected, DIP switches misconfigured, 24 V external supply missing, or bus cable damaged/unplugged.Check 24 V DC supply on module terminals, check D-Sub cable connection, verify DIP switches, replace module if internal board fault persists.
CE1Process Data Time-outTime-out during cyclic process data transfer over INTERBUS.INTERBUS master stopped cyclic communication, bus cycle time excessive, or network disturbance.Check INTERBUS master PLC run state, check master cycle settings and bus cable shielding.
CE2PCP Parameter Channel ErrorError during PCP parameter access via INTERBUS.Invalid parameter code requested, write access blocked, or PCP communication interrupted.Check PLC application program parameter address range and access permissions.
CE3Module Fault / Initialization FailureInternal hardware failure or initialization failure of EMF2111IB communication module.Defective module electronics, damaged connector pins on host interface.Re-seat communication module on drive slot; if error persists, return unit for repair or replace EMF2111IB.

Frequently Asked Questions

What software is required to configure the Lenze EMF2111IB communication module?

Configuration and parameterization can be performed using Lenze Global Drive Control (GDC) software or Phoenix Contact INTERBUS CMD software. Network addresses and basic operating modes are set directly on the module using physical DIP switches.

Why does the Lenze EMF2111IB require an external 24 V DC power supply?

The external 24 V DC auxiliary supply (operating within 18 V DC to 32 V DC) powers the module's remote bus interface independently. This ensures the INTERBUS ring topology remains continuous and uninterrupted even if the host inverter or servo drive is powered off or disconnected.

Which Lenze drives are compatible with the EMF2111IB INTERBUS module?

The EMF2111IB module plugs directly into the function module slot of Lenze 8200 vector frequency inverters (rated 0.25 kW to 90 kW) and Lenze 9300 servo drives.

What do the FO and RD diagnostic LEDs on the module indicate?

The red RD LED indicates that the outgoing remote bus interface is switched off or disconnected. The yellow/red FO LED indicates a signal quality issue or segment interruption on the incoming INTERBUS cable.

What steps are required when replacing a failed EMF2111IB module?

Before installing the replacement, mirror the hardware DIP switch settings from the original unit to match the existing network address and bus settings. Once plugged into the drive function slot, reconnect the incoming and outgoing D-Sub cables and the 24 V DC auxiliary power supply, then verify parameter setup using Lenze GDC software.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.