Lenze EMZ9371BB1A Keypad XT Programmer Module

New 
On request
Refurbished   
6 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo / 8200 Vector

The Lenze EMZ9371BB1A, also identified as the Keypad XT module (and referenced under designation EMZ9371BB and part number 00405232), is a hot-pluggable operator interface unit designed for drive parameterization, status monitoring, and fault diagnostics. Built for direct front-interface plug-in mounting via the Front Interface (FIF) slot, this compact module operates across Lenze 9300 Servo inverters, Lenze 8200 Vector frequency inverters, and Lenze Drive PLC controllers. Constructed with an IP20 protection rating, the unit features an ergonomic 9-key navigation layout and a backlit LCD display showing two lines of 16 characters for code-based menu browsing and real-time operational status readouts.

Connecting directly to host drive controllers through its front slot contacts, the EMZ9371BB1A allows maintenance personnel to carry out complete commissioning and parameter adjustments directly on the plant floor without a PC or software cables. Integrated non-volatile EEPROM memory stores complete parameter sets on board, enabling fast drive cloning and backup during unit replacement. When parameter transfer is prevented by active drive protection locks (such as Code C0002 or C0003 password locks) or when faulty hardware requires direct parameter extraction from a donor board, ABC Industrial Parts provides technical support and tested spare units to quickly restore system operation.

During active operation, the keypad presents clear text status displays and trip diagnostics directly on the backlit LCD. Operating conditions such as IMP, IMP-Block, TRIP, and READY appear alongside fault codes and error messages. Diagnostics like PRG ERROR, READ ERR, WRITE ERR, or TYPE ERR isolate interface contact disruptions, drive write-protection state, or parameter set mismatches between 9300 Servo and 8200 Vector hardware lines. In addition, real-time trip messages including TRIP OC1, TRIP OU, TRIP LU, TRIP OH, TRIP OH4, and TRIP CE0 immediately point to motor overcurrent, DC bus voltage faults, heatsink overtemperature, motor PTC trips, or process data communication timeouts. Where internal drive board faults prevent proper operation, ABC Industrial Parts offers repair options and exchange units to reduce machine downtime.

Technical Specifications

ManufacturerLenze
Part NumberEMZ9371BB1A
Model / TypeKeypad XT Programmer Module
Component TypeKeypad / Operator Interface
Product FamilyLenze 9300 Servo / 8200 Vector
Display TypeLCD, backlit
Display Resolution2 lines x 16 characters
Number of Keys9
Mounting TypeFront interface slot (FIF) plug-in
Protection RatingIP20
Parameter StorageIntegrated non-volatile EEPROM

Programming and Configuration

The Lenze EMZ9371BB1A Keypad XT serves as a standalone programming tool, allowing operators to parameterize compatible Lenze drives directly without needing a PC or external software cables. Using the 9-key keypad interface, users navigate drive code structures to modify motor control parameters, acceleration and deceleration ramps, and operational limits on the plant floor.

Through the integrated non-volatile EEPROM memory, complete parameter configurations can be saved directly into the keypad module. Operators can upload parameter sets from a running drive into the keypad memory and download them directly into a replacement unit, streamlining fleet duplication and machine replacement. When copying parameters, parameter protection passwords under Code C0002 or Code C0003 must be cleared on the target drive to prevent parameter write errors.

Communication and System Integration

The EMZ9371BB1A connects to drives via the standard Front Interface (FIF) slot located on the front panel of Lenze control boards. This hot-pluggable connection establishes direct electrical contact with the drive microchip, enabling hot insertion and removal while the drive remains energized.

The keypad integrates seamlessly into systems operating with Lenze 9300 Servo Inverters, Lenze 8200 Vector Frequency Inverters, and Lenze Drive PLCs. When fieldbus or host system communications fail, the module presents system-level alarms such as TRIP CE0, indicating process data time-outs across connected network links.

Diagnostics and Status Indication

The backlit 2x16 character LCD display delivers real-time operational status and diagnostic feedback. Machine operators can monitor drive states directly through clear text status indications including IMP, IMP-Block, TRIP, and READY.

When drive faults or parameter copy issues occur, the keypad displays immediate error descriptions and maintains active fault tracking. Operational trip messages highlight electrical, thermal, and network issues, while programming error codes isolate keypad memory access issues and hardware compatibility mismatches.

Replacement and Spare Part Considerations

When using the EMZ9371BB1A as a field commissioning or parameter backup tool during drive replacement, verify that parameter profiles originate from identical hardware families. Loading a parameter structure saved from a 9300 Servo unit into an 8200 Vector inverter triggers a TYPE ERR message due to memory architecture differences.

Prior to copying stored parameter sets to a replacement drive, ensure the target unit is powered but stopped (not in RUN mode). Additionally, check that password protections under Code C0002 and C0003 are disabled on the target drive to avoid WRITE ERR interruptions. Inspect the electrical contacts on the Front Interface slot for dust or physical damage to establish clean communication.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
PRG ERRORProgramming Error during Parameter CopyKeypad parameter transfer failed during read or write access to the drive memory.Keypad disconnected during transfer, memory checksum fault, or incompatible firmware version.Re-attach Keypad XT securely, restart parameter copy operation, or verify parameter compatibility manually.
READ ERRParameter Read ErrorKeypad failed to read parameter memory from the connected drive.Interrupted electrical connection at FIF interface or drive control board internal fault.Check keypad interface contacts for damage or contamination. Retry copy process.
WRITE ERRParameter Write ErrorKeypad failed to write stored parameter data into target drive.Target drive parameter lock / password protection enabled, drive write-protected, or communication timeout.Unlock target drive parameters via password (Code C0002/C0003), verify drive state is not in RUN mode, and re-attempt parameter transfer.
TYPE ERRDrive Type / Parameter MismatchParameter set in Keypad memory belongs to a different drive family or incompatible hardware variant.Attempting to copy a 9300 servo parameter set into an 8200 vector drive or incompatible model.Ensure source and target drives are from the same series and share compatible hardware architecture. Perform manual parameterization.
TRIP OC1Short Circuit / Overcurrent Phase 1Drive trip displayed on keypad screen indicating instantaneous overcurrent.Motor cable short-circuit, ground fault, or excessive acceleration rate.Check motor wiring and insulation. Check drive output stage.
TRIP OUOvervoltage DC BusDrive trip displayed on keypad screen indicating excessive DC bus voltage.Regenerative energy during deceleration, missing or defective brake chopper / resistor.Increase deceleration time or inspect brake resistor connections.
TRIP LUUndervoltage DC BusDrive trip displayed on keypad screen indicating low mains input voltage or DC bus supply voltage.Mains supply failure, phase loss, or blown input fuse.Check AC line voltage supply and fuses.
TRIP OHHeatsink OvertemperatureDrive trip displayed on keypad screen indicating excessive drive internal heatsink temperature.Cooling fan failed, clogged heatsink, ambient temperature too high, or drive overload.Clean heatsink, verify enclosure fan operation and cabinet ventilation.
TRIP OH4Motor Overtemperature (PTC / Thermal Contact)Drive trip displayed on keypad screen triggered by motor thermal sensor.Motor thermal overload or disconnected thermal contact wiring.Allow motor to cool down, inspect load, and verify PTC sensor connections.
TRIP CE0Communication Error (Process Data Time-out)Drive trip displayed on keypad screen due to lost system fieldbus/communication link.Interrupted fieldbus cable connection, master offline, or network termination issue.Check fieldbus cabling, connector seating, and master controller diagnostic status.

Frequently Asked Questions

Which drive series are compatible with the Lenze EMZ9371BB1A Keypad XT?

The EMZ9371BB1A is compatible with Lenze 9300 Servo Inverters, Lenze 8200 Vector Frequency Inverters, and Lenze Drive PLCs equipped with a Front Interface (FIF) slot.

Can I transfer parameters between a 9300 Servo drive and an 8200 Vector drive?

No. Parameter sets saved from a 9300 Servo drive cannot be downloaded into an 8200 Vector drive. Doing so triggers a TYPE ERR fault code on the keypad display. Parameter transfers must occur between units of the same drive family.

What causes a WRITE ERR message when transferring parameters to a drive?

A WRITE ERR message occurs if the target drive is parameter write-protected via password (Code C0002/C0003), if the drive is currently in RUN mode, or if communication across the FIF interface is interrupted.

Is the Lenze EMZ9371BB1A keypad hot-pluggable?

Yes. The EMZ9371BB1A Keypad XT is hot-pluggable and can be connected to or removed from the drive Front Interface slot while the drive unit is powered.

Does parameter backup with the EMZ9371BB1A require a PC or external software?

No. The EMZ9371BB1A contains integrated non-volatile EEPROM memory that stores parameter sets directly onboard, allowing complete parameter backup, copying, and drive cloning without a PC or software.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.