Lenze 00470806 EVS9325-ES 9300 Servo Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 00470806 EVS9325-ES is a 5.5 kW servo inverter from the 9300 Servo series, designed for high-precision motor speed, torque control, and synchronized motion applications. Operating on a 3-phase AC supply ranging from 320 V AC to 528 V AC, this drive supplies a rated output current of 13 A with a 150% peak overload capacity reaching 19.5 A for up to 60 seconds. Featuring an IP20 protection rating and an 8 kHz switching frequency, the inverter delivers high dynamic positioning response for multi-axis machinery, electronic shafting, and master-slave gear synchronization.
Connecting a replacement unit into an existing line requires matching feedback interfaces and communication setups. The EVS9325-ES provides Sub-D 9-pin inputs for standard resolvers and Sub-D 15-pin connections for incremental or SinCos absolute encoders, along with 5 digital inputs, 4 digital outputs, 2 analog inputs, and 2 analog outputs. Communication is provided onboard via a CAN system bus operating up to 500 kbps, supplemented by a multi-pin Automation Interface (AIF) slot that supports fieldbus modules such as EMF2133IB PROFIBUS-DP, EMF2175IB CANopen, INTERBUS, or LECOM adapters. Drive parameterization relies on internal EEPROM memory capable of holding up to four complete, switchable parameter sets, which can be extracted from a donor board or transferred directly using an EMZ9371BC keypad or Lenze Global Drive Control (GDC) software. Technical support for parameter extraction and drive commissioning is available through ABC Industrial Parts.
Visual operational status is supplied directly through front-panel LEDs, including Green (DRIVE READY / POWER), Red (DRIVE ERROR / TRIP), and Yellow (IMPULSE INHIBIT / WARNING), as well as a fail-safe TRIP relay output contact and CAN bus status word monitoring. System trip codes like OU for DC bus overvoltage, LU for DC bus undervoltage, LP1 for input phase loss, and feedback faults Sd2 or Sd3 isolate external power and wiring issues. Internal electronic failures, such as EE0 EEPROM corruption or H05 hardware faults, indicate board-level failures that cannot be repaired in the field, making unit replacement or off-site repair through ABC Industrial Parts the ideal solution to restore machine uptime.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 00470806 |
| Model/Type | EVS9325-ES |
| Component Type | Servo Inverter |
| Product Family | 9300 Servo |
| Rated Power | 5.5 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Rated Output Current | 13 A |
| Peak Output Current | 19.5 A |
| Power Dissipation | 220 W |
| Max Output Frequency | 600 Hz |
| Switching Frequency | 8 kHz |
| CAN Bus Speed | 500 kbps |
| Digital I/O Channels | 5 Inputs / 4 Outputs |
| Analog I/O Channels | 2 Inputs / 2 Outputs |
| Protection Rating | IP20 |
Programming and Configuration
Configuration and commissioning of the Lenze 00470806 EVS9325-ES are performed using Lenze Global Drive Control (GDC) software or the pluggable EMZ9371BC operating keypad. The drive stores parameter settings in non-volatile internal EEPROM memory, accommodating up to four distinct, switchable parameter sets. This internal storage structure allows complete drive setups to be backed up, modified, or restored without loss of configuration during main power interruptions.
When putting a replacement inverter into service, parameter sets can be copied from the original drive using the EMZ9371BC keypad or uploaded and downloaded via GDC software over a serial or fieldbus connection. Proper alignment of parameter configurations, motor feedback parameters, and current limit thresholds is necessary to ensure correct positioning accuracy, speed loop stability, and control interface behavior.
Communication and System Integration
The EVS9325-ES comes equipped with an onboard CAN system bus interface capable of communication speeds up to 500 kbps. This integrated bus allows fast multi-axis data exchange, real-time status word monitoring, master-slave frequency coupling, and electronic gearbox synchronization across interconnected 9300 Servo drives.
For broader fieldbus integration, the unit features a modular Automation Interface (AIF) slot. This slot accepts optional communication adapters, including the EMF2133IB PROFIBUS-DP module and the EMF2175IB CANopen module, as well as INTERBUS and RS-232/RS-485 LECOM adapters. External system control is further supported through 5 digital inputs, 4 digital outputs, 2 analog inputs, and 2 analog outputs.
Diagnostics and Status Indication
Diagnostic monitoring on the Lenze 00470806 EVS9325-ES is provided through three front-panel status LEDs, diagnostic readouts on the EMZ9371BC keypad, real-time diagnostic windows within Global Drive Control (GDC) software, and CAN bus status words. A fail-safe TRIP relay switch contact also opens to alert high-level system controllers when a fault condition shuts down the drive.
The status LEDs deliver instantaneous status updates regarding power supply activation, active fault trips, and control inhibit states to facilitate quick initial checks.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| DRIVE READY / POWER | Green - Solid | Drive operational status and power supply active |
| DRIVE ERROR / TRIP | Red - Solid / Flashing | Drive trip fault or critical error detected |
| IMPULSE INHIBIT / WARNING | Yellow - Solid / Flashing | Impulse inhibit active or warning limit reached |
Replacement and Spare Part Considerations
When replacing a Lenze 00470806 EVS9325-ES servo inverter, verify that the replacement matches the exact model number and electrical ratings, specifically the 5.5 kW power rating and 13 A continuous current capacity. Ensure that any installed optional modules, such as AIF fieldbus communication cards (e.g., EMF2133IB or EMF2175IB), are transferred to the replacement unit prior to power-up.
Because drive behavior relies on application-specific settings, parameter sets saved in the original drive's EEPROM must be transferred to the replacement unit using the EMZ9371BC keypad or Global Drive Control software. Check feedback wiring on Sub-D terminals X7 and X8, as well as CAN network termination resistors and node address settings, to ensure proper synchronization upon restart.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit | Short circuit at the motor output terminals. | Short circuit in motor cable or motor winding, ground fault, or power stage transistor short circuit. | Check motor wiring and insulation. Disconnect motor and check drive power stage. Internal board fault requires return for repair. |
| OC2 | Earth Fault | Ground fault detected on output motor phase. | Ground fault in motor lead or motor frame grounding error. | Check motor and wiring for insulation breakdown to ground. |
| OC5 | I x t Overload | Drive overload monitor triggered (Ixt exceeded allowable threshold). | Mechanical overload, drive undersized, continuous operation above rated current. | Check machine mechanics, reduce motor load or duty cycle, check current limit settings. |
| OU | Overvoltage DC Bus | DC bus voltage exceeded upper limit (>770 V DC). | Excessive regenerative energy during deceleration, brake chopper non-functional, or missing brake resistor. | Extend deceleration time, check braking chopper transistor, check external brake resistor. |
| LU | Undervoltage DC Bus | DC bus voltage fell below lower limit (<430 V DC). | Mains voltage supply line collapse, phase loss, or power supply brownout. | Check input mains voltage, fuse connections, and main contactor. |
| OH | Heatsink Overtemperature | Drive heatsink temperature exceeded maximum threshold (>90°C). | Insufficient cabinet ventilation, cooling fan failure, dirty heatsink fins, or ambient temperature too high. | Clean heatsink, inspect internal cooling fan, improve control cabinet ventilation. |
| OH4 | Heatsink Temperature Warning | Heatsink temperature near critical threshold. | Elevated ambient cabinet temperature or restricted cooling air flow. | Verify cabinet cooling performance before unit trips on OH. |
| OH7 | Motor Overtemperature | Motor temperature sensor trip (PTC or KTY sensor). | Motor thermal overload, low cooling air speed at reduced motor RPM, or damaged thermal sensor cable. | Allow motor to cool, check motor fan operation, inspect temperature sensor connections. |
| CE0 | CAN Communication Fault | System bus (CAN) communication error. | CAN network cable broken, improper termination resistor, or CAN bus traffic interruption. | Check CAN wiring, shield grounding, 120-ohm termination resistors, and node addresses. |
| CE1 | Automation Interface (AIF) Fault | Communication failure between drive control board and optional AIF fieldbus module. | Module loose in slot, defective fieldbus module, or fieldbus network timeout. | Re-seat module in AIF slot, check fieldbus cable connection, replace AIF communication module if failure persists. |
| EE0 | EEPROM Error | Data corruption during read/write to internal non-volatile EEPROM memory. | Internal memory corruption or hardware memory chip failure. | Load factory default parameters (PAR LOAD) and write project data again. If error recurs, internal board fault requires repair or unit replacement. |
| H05 | Internal Hardware Fault | Internal control hardware failure or internal voltage rail monitoring error. | Control board component fault or internal power supply failure. | Cycle power. If fault persists, the internal hardware is defective; return unit for factory repair or replace drive. |
| NMAX | Speed Overspeed Limit | Motor speed exceeded maximum limit (1.2 x maximum speed setting). | Incorrect feedback setup, feedback cable noise, or unstable speed loop tuning. | Check encoder/resolver wiring, check speed loop gain settings, check parameter NMAX. |
| Sd2 | Resolver Feedback Fault | Resolver signal connection lost or signal corrupted. | Broken resolver wire, defective plug, line noise on X7 connector. | Check resolver connection on X7, check cable shielding, test resolver resistance. |
| Sd3 | Encoder Signal Fault | Incremental encoder signal track error or line break detected on X8. | Loose connector, cut wire, or faulty encoder track A/B. | Inspect X8 encoder plug and cable, verify encoder supply voltage. |
| LP1 | Input Phase Loss | One phase of the 3-phase mains supply is missing. | Blown main fuse, loose power wiring connection, or supply phase failure. | Check all 3 input mains phases (L1, L2, L3) for full voltage under load. |
Frequently Asked Questions
How do I transfer parameter settings to a replacement Lenze 00470806 drive?
Parameters stored in internal EEPROM memory can be cloned using the pluggable EMZ9371BC operating keypad or uploaded and downloaded via Lenze Global Drive Control (GDC) software.
What motor feedback devices are supported by the EVS9325-ES servo inverter?
The drive natively supports standard resolvers via Sub-D 9-pin connections and incremental or SinCos absolute encoders via Sub-D 15-pin connections.
What fieldbus communication options can be added to the EVS9325-ES?
In addition to the onboard CAN system bus operating up to 500 kbps, optional fieldbus modules such as EMF2133IB PROFIBUS-DP, EMF2175IB CANopen, INTERBUS, and LECOM adapters can be installed into the Automation Interface (AIF) slot.
What does fault code H05 or EE0 indicate on the drive?
Fault EE0 indicates data corruption within the internal EEPROM, while code H05 indicates an internal control hardware or power supply failure. If clearing or reloading parameters does not clear the condition, internal hardware repair or unit replacement is required.
What supply voltage range does the Lenze 00470806 require?
The unit operates on a 3-phase AC supply voltage between 320 V AC and 528 V AC at 45 to 65 Hz.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.