The Lenze 00470841 EVS9330-ES is a 45 kW servo inverter drive from the Lenze 9300 Servo family, engineered for high-precision vector-oriented motor control in complex multi-axis industrial automation systems. Designed for demanding applications such as packaging machinery, textile manufacturing, automotive assembly, and converting lines, this drive operates across a 3-phase supply voltage range of 320 V AC to 528 V AC. It provides an 89 A continuous output current and features a 150% peak overload capacity (up to 133.5 A) to handle heavy dynamic acceleration and precise torque or speed control requirements.

Interfacing the EVS9330-ES into an existing control cabinet relies on flexible feedback and network connections, including a dedicated 9-pin D-sub resolver input at interface X7 and encoder input/output channels at X8 and X9 supporting signal frequencies up to 500 kHz. For system-level integration, the integrated CAN-based Lenze System Bus at interface X4 enables direct cross-axis synchronization at rates up to 500 kbit/s, while Option Slot A accepts optional fieldbus modules such as the EMF2131IB or EMF2133IB for PROFIBUS-DP and EMF2172IB for CANopen. Commissioning a replacement unit requires restoring parameter settings, which can be transferred using Lenze Global Drive Control (GDC) software, Easy Starter, or an EMZ9371BC keypad by drawing from the drive onboard EEPROM memory that holds up to four independent parameter sets. When installing a replacement drive, ABC Industrial Parts can assist in ensuring configuration parameter files and option modules are properly transferred before putting the machine back into service.

Operational monitoring and fault diagnostics are provided via front-panel dual LEDs, the optional EMZ9371BC pluggable keypad, and GDC diagnostic software, alongside an integrated fault history register (Code C0168) that retains up to 8 recorded fault events. A solid green LED indicates normal enabled operation, while a blinking green LED signals a controller inhibit (CINH) state; a solid red LED denotes an active TRIP fault state that disables the output stage, and a blinking red LED signals an active warning. System fault codes address conditions such as overcurrent (OC1), earth faults (OC2), DC bus overvoltage or undervoltage (OU, LU), heatsink or ambient overtemperature (OH, OH4), feedback signal interruptions (P12, P13), and communication errors on Slot A (CE0) or System Bus (CE1). For internal hardware faults such as code H05 or EEPROM corruption (EER) that cannot be cleared through a power cycle or parameter reload, internal board failures are not field-serviceable, making repair services or a fully tested exchange unit from ABC Industrial Parts the most reliable path to restore production.

Technical Specifications

Rated Output Power45 kW
Supply Voltage Range320 - 528 V AC
Rated Continuous Current89 A
Peak Output Current133.5 A
Switching Frequency8 kHz
Maximum Output Frequency480 Hz
Digital Inputs4
Digital Outputs2
Analog Inputs2
Analog Outputs2

Programming and Configuration

Parameterization and commissioning of the Lenze EVS9330-ES servo drive are performed using Lenze Global Drive Control (GDC) software, Easy Starter, or the pluggable EMZ9371BC diagnostic keypad. The drive contains non-volatile EEPROM memory capable of storing up to four complete, independent parameter sets. This onboard memory architecture enables convenient cloning and rapid backup of drive settings across identical axes or replacement units.

Commissioning a spare drive requires matching drive parameters to the specific motor characteristics, position feedback devices, and application safety thresholds. Settings can be uploaded from an existing drive or written directly to the target drive using GDC software or by transferring saved parameter files via the EMZ9371BC keypad. Selecting factory default restoration (Code C0002=1) allows technicians to clear legacy parameters prior to reloading clean application configurations.

Communication and System Integration

High-speed multi-axis communication on the EVS9330-ES is handled directly via the integrated Lenze System Bus at connection X4. Utilizing CAN technology running at transmission speeds up to 500 kbit/s, this bus allows rapid cross-axis data exchange, synchronized speed hold, and positioning commands between multiple drives without requiring external motion control hardware.

For integration with higher-level plant automation networks, the drive features a dedicated expansion interface designated as Option Slot A. Modular fieldbus adapters, including the EMF2131IB / 2133IB PROFIBUS-DP module and the EMF2172IB CANopen module, install directly into Option Slot A. Proper bus installation requires verified cable shielding, matching network baud rates, and correct 120-ohm termination resistors at both ends of the CAN system bus line.

Diagnostics and Status Indication

The EVS9330-ES provides real-time status feedback through front-mounted dual LED indicators, the pluggable EMZ9371BC keypad display, and live monitoring within Lenze Global Drive Control (GDC) software. Fault history analysis is supported by internal register Code C0168, which logs up to 8 historical fault events for diagnostic review and root-cause troubleshooting.

The primary status indicators consist of a green Operation/Ready LED and a red TRIP/Fault LED. The green LED glows solid when the drive controller is enabled and operational, and blinks when controller inhibit (CINH) is active. The red LED illuminates solid when a TRIP fault condition disables the output stage, and blinks when an active system warning is detected.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (Operation / Ready)Green - Solid / BlinkingSolid: Controller enabled, normal operating state. Blinking: Controller inhibit active (CINH).
Red LED (TRIP / Fault)Red - Solid / BlinkingSolid: Active fault (TRIP state, output stage disabled). Blinking: Warning active.

Replacement and Spare Part Considerations

When replacing an existing Lenze EVS9330-ES (00470841) servo drive, verify that the physical unit matches the required 45 kW power rating and 89 A continuous output specification. Ensure any installed fieldbus option module in Option Slot A, such as PROFIBUS-DP or CANopen cards, is transferred to the replacement drive to preserve network connectivity.

Before enabling the replacement drive, parameter memory must be synchronized. Parameter sets stored in the EEPROM of the original drive can be extracted using GDC software or transferred via the EMZ9371BC keypad. Following parameter download, verify motor feedback signal integrity at sockets X7, X8, or X9, confirm bus termination resistance on interface X4, and check thermal sensor connections at terminals T1 and T2 prior to applying mains power.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / OvercurrentInstantaneous hardware overcurrent limit exceeded.Short circuit in motor cable, winding ground fault, or incorrect motor parameterization.Check motor wiring and isolation, inspect motor windings, verify acceleration ramps.
OC2Earth faultGround fault current detected at output terminals.Ground connection in motor cable, stator winding insulation failure to ground.Check motor and cable insulation resistance with megohmmeter.
OC5Ixt overloadCalculated thermal overload of the drive output stage.Continuous current demand above drive rating, mechanical overload, stuck rotor.Check mechanical load, increase ramp time, check motor size matching.
OUOvervoltage DC busDC bus voltage exceeded threshold (> 770 V DC).Excessive regenerative energy from motor during deceleration, missing or undersized brake resistor.Extend deceleration time, install or check external braking resistor and chopper.
LUUndervoltage DC busDC bus voltage fell below minimum threshold (< 420 V DC).Mains supply voltage drop, phase loss, blown supply fuse.Check mains voltage supply, incoming fuses, and main contactor.
OHHeatsink overtemperatureDrive heatsink temperature exceeded upper limit.Inadequate cooling airflow, failed internal fan, clogged heatsink fins.Clean heatsink, verify cabinet ventilation and internal drive fans operation.
OH3Motor temperature sensorMotor thermistor / PTC / Klixon switch triggered.Motor thermal overload, cooling fan failure on motor, open temperature sensor wire.Allow motor to cool, check motor fan, inspect thermal sensor connection at terminals T1/T2.
OH4Inside device temperatureInternal air temperature inside drive enclosure exceeded threshold.Ambient temperature inside control cabinet too high, cabinet fan failure.Check control cabinet air conditioning and fan filtration.
NMAXSpeed threshold exceededActual motor speed exceeded maximum configured threshold.Speed loop instability, external driving load, wrong encoder resolution settings.Check speed controller tuning, check load conditions and encoder settings.
P12Resolver faultLoss or disruption of resolver feedback signal.Resolver cable disconnected, broken wire, damaged resolver on motor.Inspect resolver cable shield and pin connections at socket X7.
P13Encoder faultFault detected on incremental or absolute encoder signal.Defective encoder cable, missing supply voltage to encoder, signal interruption.Check encoder connection at X8/X9 socket and cable integrity.
CE0Communication error Slot ALoss of fieldbus communication via module inserted in Slot A.Bus connection interrupted, master stopped sending telegrams, module loose.Check fieldbus wiring, check master PLC state, re-seat option module.
CE1System bus CAN faultCAN error state passive or bus-off on System Bus X4.Bus line short/open circuit, missing bus termination resistors (120 Ohm), baud rate mismatch.Check CAN bus wiring, termination resistors on both ends, and baud rate setting.
EEREEPROM memory errorEEPROM checksum failure during boot or parameter read.Power failure during save procedure, internal memory degradation.Reload factory default settings (C0002=1) and re-download parameter file. If persistent, return unit for repair.
H05Internal hardware faultPower section or control board hardware failure detected during self-test.Internal board failure or corrupted control hardware.Internal hardware fault — power cycle drive; if persistent, return unit for service or replace.

Frequently Asked Questions

How are parameters copied from an existing EVS9330-ES to a replacement drive?

Parameters can be cloned using an EMZ9371BC diagnostic keypad or Lenze Global Drive Control (GDC) software by uploading the configuration from the original drive's onboard EEPROM and downloading it into the new unit.

What input supply voltage does the Lenze EVS9330-ES require?

The drive operates on a 3-phase AC input voltage range of 320 V AC to 528 V AC.

How does the EVS9330-ES communicate across multiple drive axes?

The drive features an integrated CAN-based Lenze System Bus at interface X4, operating at up to 500 kbit/s for multi-axis drive synchronization without an external motion controller.

What do the green and red status LEDs on the front panel indicate?

A solid green LED indicates normal enabled operation, while a blinking green LED indicates controller inhibit (CINH). A solid red LED indicates a TRIP fault state with output disabled, while a blinking red LED indicates an active warning.

What steps should be taken if fault code H05 or EER occurs?

Fault code EER indicates an EEPROM checksum error, which can be resolved by loading default settings (C0002=1) and re-downloading parameters. Fault code H05 indicates an internal hardware failure; if power cycling does not clear it, the drive requires repair or unit replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.