The Lenze 13351551 E84AVBCE2512SX0 is a compact 0.25 kW frequency inverter from the L-force 8400 Baseline series designed for speed control in low-power industrial drives. Operating from a single-phase 230 V AC supply across a 180 V to 264 V AC voltage range, this panel-mounted drive supports both Sensorless Vector Control (SLVC) and V/f characteristic control modes. It delivers a rated output current of 1.7 A at an 8 kHz switching frequency and a maximum output current of 2.4 A at 4 kHz, making it suitable for material handling belt conveyors, packaging machinery feeder lines, centrifugal pumps, and ventilation fans.
System connectivity includes an integrated CANopen fieldbus interface capable of communication speeds up to 1 Mbit/s, alongside 4 digital inputs, 1 digital output, 1 analog input, and 1 relay output. Direct parameter assignment and commissioning are performed using the onboard RJ45 diagnostic interface connected to the optional Keypad XT (E84EZKFX001) or PC-based Lenze EASY Starter and Lenze Engineer software via the USB Diagnostic Adapter (E84AVZDE). Replacing a unit in service is simplified by the pluggable L-force Memory Module (E84AYM01), which holds the complete drive parameter set. Transferring the existing module to a replacement drive allows parameter duplication without specialized software, while ABC Industrial Parts provides assistance with parameter extraction from damaged units.
Status monitoring is indicated on the front panel via dual Green (Ready) and Red (Error) diagnostic LEDs, supplemented by the diagnostic history buffer in Lenze EASY Starter or CANopen emergency messages (EMCY). First-line troubleshooting involves checking single-phase mains supply stability, inspecting motor insulation and wiring for short circuits or ground faults, and verifying that the memory module is seated securely. When internal board-level faults or EEPROM access errors prevent operation, replacing the drive or utilizing testing services through ABC Industrial Parts ensures minimal operational downtime.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13351551 |
| Model / Type | E84AVBCE2512SX0 |
| Product Family | L-force 8400 |
| Series | 8400 Baseline |
| Component Type | Frequency Inverter |
| Rated Power | 0.25 kW |
| Supply Voltage | 230 V AC |
| Supply Voltage Range | 180 - 264 V AC |
| Rated Output Current (8 kHz) | 1.7 A |
| Max Output Current (4 kHz) | 2.4 A |
| Switching Frequency | 8 kHz |
| Control Method | Sensorless Vector Control (SLVC) / V/f characteristic control |
| Integrated Fieldbus | CANopen |
| Max Fieldbus Speed | 1 Mbit/s |
| Digital Inputs | 4 |
| Digital Outputs | 1 |
| Analog Inputs | 1 |
| Relay Outputs | 1 |
Programming and Configuration
Commissioning and parameterization of the Lenze 13351551 frequency inverter are carried out using Lenze EASY Starter or Lenze Engineer software suites. Connection to a PC is established through the onboard RJ45 diagnostic interface using the optional USB Diagnostic Adapter (E84AVZDE). Alternatively, hand-held adjustments and status modifications can be performed directly on the cabinet panel via the optional Lenze Keypad XT (E84EZKFX001).
The inverter stores its functional parameters on the pluggable L-force Memory Module (E84AYM01). This removable memory element enables parameter duplication across multiple drives and tool-free device replacement. During hardware swapping, the module is transferred to the replacement drive to reinstate complete motor control and fieldbus configurations without requiring a software connection.
Communication and System Integration
The Lenze 13351551 features an integrated CANopen system bus interface natively supporting transmission speeds up to 1 Mbit/s. This fieldbus connectivity allows direct integration into centralized automation systems and decentralized drive topologies without requiring add-on fieldbus communication cards.
For direct control and feedback wiring, the unit provides 4 digital inputs, 1 digital output, 1 analog input, and 1 relay output. Remote control commands, speed setpoints, and operational feedback can be routed through physical I/O terminals or transmitted cyclically over the CANopen network.
Diagnostics and Status Indication
Visual status diagnostics are provided by front-mounted LED indicators. The green Ready LED displays operational availability and output status, while the red Error LED signals active warnings or trip faults.
Detailed fault diagnostics are accessible via the Keypad XT error log history, CANopen emergency messages (EMCY), or the diagnostic buffer in Lenze EASY Starter software when connected through the RJ45 diagnostic port.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Ready | Green - Off / Blinking / Solid | Off: Drive de-energized or initializing. Blinking: Drive ready for operation, output inhibited. Solid: Drive running and operational. |
| Error | Red - Off / Blinking / Solid | Off: No active fault. Blinking: Warning or light error active. Solid: Critical fault active, inverter output inhibited. |
Replacement and Spare Part Considerations
When replacing a Lenze 13351551 frequency inverter, transfer the existing pluggable L-force Memory Module (E84AYM01) to the new inverter hardware. This memory card retains all configuration parameters, removing the need to connect PC tools during hardware swaps.
Ensure that physical control wiring, line power connections, and CANopen network cabling match the original layout. For installations migrating to newer hardware series, the Lenze i510 Cabinet Series unit (i51AEU125B0000000S) serves as a functional successor.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| 0x00210001 | OC1 / Short Circuit | Short circuit or ground fault at inverter output terminals. | Short circuit in motor cable or motor winding, ground fault, excessively long motor cables. | Check motor and motor wiring for short circuits and ground faults; check cable length and motor insulation resistance. |
| 0x00210002 | OC2 / Acceleration Overcurrent | Excessive motor current during acceleration ramp. | Acceleration time too short, mechanical overload or drive stall, incorrectly parameterized motor data. | Increase acceleration time; check mechanical system for blockages; verify motor parameters. |
| 0x00210005 | OC5 / I2t Motor Overload | Motor overload condition detected by thermal I2t motor protection model. | Continuous motor overload, motor operation below rated speed with high torque without forced cooling. | Reduce motor load; verify motor sizing and cooling method. |
| 0x00210009 | OH / Heatsink Overtemperature | Heatsink temperature exceeded upper safety limit. | Insufficient cabinet cooling, heatsink dirty, ambient temperature too high, switching frequency set too high. | Clean heatsink cooling fins, verify cabinet airflow, lower ambient temperature or reduce switching frequency. |
| 0x0021000a | OH4 / Inside Device Overtemperature | Internal ambient enclosure temperature inside drive exceeded safety limit. | Excessive internal cabinet temperature, poor ventilation around drive. | Improve enclosure ventilation and clearance around inverter. |
| 0x0021000b | LU / Undervoltage | DC bus voltage fell below low voltage threshold. | Mains supply voltage too low, line phase loss, power supply interruption. | Check supply voltage magnitude and consistency, inspect line supply input power and fuses. |
| 0x0021000c | OU / Overvoltage | DC bus voltage exceeded upper limit. | Generatoric motor operation during deceleration, deceleration ramp set too fast without braking resistor. | Extend deceleration time, connect optional braking module/resistor, enable Vdc max controller. |
| 0x00320001 | EER / EEPROM Error | Communication failure or checksum error accessing memory module. | Memory module missing, loose, damaged, or corrupted parameter data. | Verify memory module is seated firmly; reload parameter backup or replace memory module / inverter internal board. |
Frequently Asked Questions
How do I transfer parameters to a replacement Lenze 13351551 drive?
Parameters are transferred by removing the L-force Memory Module (E84AYM01) from the original unit and inserting it into the replacement drive. The parameters load automatically upon power-up.
What software is used to configure the Lenze E84AVBCE2512SX0?
Configuration and diagnostic software options include Lenze EASY Starter and Lenze Engineer, connected via the USB Diagnostic Adapter (E84AVZDE) to the inverter's RJ45 port.
What does a solid red Error LED indicate on the drive?
A solid red Error LED indicates a critical active fault condition that inhibits the inverter output stage.
What fieldbus communication is built into the 8400 Baseline inverter?
The inverter features an integrated CANopen interface that supports communication speeds up to 1 Mbit/s.
What is the recommended successor model for the 13351551 inverter?
The recommended successor in the Lenze product line is the Lenze i510 cabinet series model i51AEU125B0000000S.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.