The Lenze E82EV251-2C is a compact frequency inverter from the 8200 Vector series, engineered for precise variable speed regulation of three-phase AC motors in industrial machinery. Designed to operate on a 230 V AC single-phase or three-phase input supply with an acceptable voltage range of 180 to 264 V AC, this drive delivers a rated power output of 0.25 kW with a continuous output current of 1.7 A and a 3.4 A rated input current. It supports multiple motor control methods, including linear V/f characteristics, frequency control (VFC), and advanced sensorless vector control to maintain dynamic speed stability and low-end torque across an output frequency range of 0 to 480 Hz. Featuring a 150% maximum overload capability for 60 seconds (up to 2.55 A peak overload current) and selectable switching frequencies between 2 kHz and 16 kHz with an 8 kHz default, it provides quiet and reliable operation for conveyor drives, packaging material feeds, ventilation fans, and small pumps.

The drive utilizes a modular hardware design that separates the base power unit from plug-in operating keypads and network communication modules. Integrating a replacement unit into a production line requires matching physical option slots and transferring unit configuration. Commissioning and parameterization are performed using Lenze Global Drive Control (GDC) software version 4.0 or higher, or through optional pluggable keypads such as the EMZ8201BB standard panel or the EMZ8211BB XT keypad module. The inverter houses internal EEPROM memory supporting up to four independently selectable parameter sets, allowing multiple machine operating profiles to be saved locally. When replacing a failed unit, stored parameter sets must be uploaded from the original unit or downloaded from a software backup to ensure identical control settings. ABC Industrial Parts supports engineering teams with replacement hardware and parameter extraction strategies to streamline installation.

Real-time drive status is indicated by front-panel LEDs and diagnostic parameter readouts. A solid green LED confirms normal operating status with the inverter enabled, slow green flashing at 1 Hz indicates an inverter inhibit state, and fast green flashing at 2 Hz signifies quick stop or zero setpoint selection. A solid red LED signals an active TRIP fault, slow red flashing indicates a warning, and fast red flashing points to an active fault with automatic restart pending; if both LEDs are unlit, line power is disconnected or an internal power supply issue exists. Active faults and fault history are logged under parameter C0168, while operating parameters such as output frequency, DC bus voltage, and motor current are monitored in parameters C005x. First-line troubleshooting should verify input mains voltage, check motor insulation, and inspect fieldbus connections. When internal gate driver circuits or micro-controller memory failures occur, ABC Industrial Parts offers tested exchange units and professional repair services to reduce equipment downtime.

Technical Specifications

ManufacturerLenze
Part NumberE82EV251-2C
Model / Series8200 Vector
Component TypeFrequency Inverter
Rated Power0.25 kW
Supply Voltage230 V AC
Supply Voltage Range180 - 264 V AC
Rated Input Current3.4 A
Continuous Output Current1.7 A
Maximum Overload Current2.55 A (150% for 60 s)
Output Voltage Range0 - 230 V AC
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz (Selectable 2 - 16 kHz)
Control MethodsV/f, VFC, Sensorless Vector Control

Programming and Configuration

Parameterization and commissioning of the Lenze E82EV251-2C frequency inverter are conducted using Lenze Global Drive Control (GDC) software version 4.0 or higher, or via direct keypad interaction. The drive includes non-volatile EEPROM memory engineered to store up to four complete, independently selectable parameter sets, enabling rapid transition between different production recipes without reconfiguring individual motor parameters.

Operator control and cloning are managed using optional plug-in interfaces. The EMZ8201BB Standard Operating Keypad provides basic display and parameter editing, while the EMZ8211BB XT Keypad Module features onboard memory for uploading, storing, and downloading drive configurations directly between units without a PC. In cases of corrupted parameters or EEPROM checksum errors (faults PR0 or C003), a factory reset can be executed using parameter C002 before reloading saved parameter sets.

Communication and System Integration

The modular construction of the 8200 Vector series allows the E82EV251-2C to adapt to various fieldbus systems and I/O requirements via plug-in function modules. Standard terminal interface functions for analog and digital control signals are provided by installing the E82ZAFSC010 Standard I/O Function Module into the drive's option slot.

For integrated network operation, the drive supports network modules including the E82ZAFCC010 CANopen Communication Module and the E82ZAFPC001 PROFIBUS-DP Communication Module, as well as System Bus (CAN) and LECOM serial interfaces (RS232/RS485). Communication timeouts, invalid parameter telegrams, or bus interruptions trigger dedicated diagnostic fault codes CE0 through CE4, requiring verification of cable shielding, 120-ohm bus termination resistors, node IDs, and master controller communication states.

Diagnostics and Status Indication

The E82EV251-2C provides comprehensive visual and software diagnostics to identify operating conditions and system faults. The front-panel green and red LEDs reflect drive status, quick stop conditions, TRIP errors, and pending restarts. Advanced diagnostics can be conducted via the EMZ8201BB or EMZ8211BB keypads or through the GDC software diagnostic suite.

Active drive parameters can be interrogated in real time under parameter group C005x, which monitors key variables including output frequency, DC bus voltage, motor current, and internal status flags. Active TRIP faults and historical error logs are stored in parameter C0168 for fast fault analysis.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (Operation)Green - Solid / FlashingLit continuously: Inverter enabled, operating normally. Flashing slowly (1 Hz): Inverter inhibited (CINH / IMP). Flashing rapidly (2 Hz): Quick stop active or setpoint 0 selected.
Red LED (Fault / Warning)Red - Solid / FlashingLit continuously: TRIP fault active. Flashing slowly (1 Hz): Warning active. Flashing rapidly (2 Hz): Fault active with automatic restart pending.
Both LEDs OffNone - OffMains supply voltage missing, DC bus unpowered, or internal power supply hardware failure present.

Replacement and Spare Part Considerations

When swapping a damaged or failed Lenze E82EV251-2C inverter, plant engineers must confirm that the replacement matches the exact part number to guarantee identical voltage ratings (230 V AC), power output (0.25 kW), and continuous output current capability (1.7 A). Because the drive stores operating parameters locally, installing a replacement unit requires restoring the parameter configuration from an EMZ8211BB XT keypad module or downloading a saved project via Global Drive Control (GDC) software.

For facilities planning comprehensive machine modernizations, Lenze recommends the i550 Cabinet Inverter series as a modern migration path. However, replacing an existing drive with a direct-fit E82EV251-2C unit avoids cabinet wiring modifications, panel layout redesigns, and controller reprogramming, allowing rapid restoration of operational machinery.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit on motor phase output or overcurrent during accelerationShort circuit in motor cable or motor winding, acceleration time too short, motor improperly dimensionedCheck motor and output wiring for short circuits, increase acceleration time, check motor parameters
OC2Earth FaultEarth/ground fault on output terminalsEarth fault in motor cable or motor winding, capacitive leakage currents in excessive motor cable lengthCheck motor cable and motor for insulation breakdown to ground, reduce motor cable length or fit output filter
OC5Ixt OverloadInverter overload / thermal utilization faultContinuous current demand exceeding rated inverter current for longer than allowable limitCheck drive sizing, reduce mechanical load, increase acceleration/deceleration times
OUOvervoltageDC bus overvoltage threshold exceeded (> 400 V DC for 230 V unit)Excessive regenerative energy during deceleration, deceleration ramp time too short, mains voltage too highIncrease deceleration time, install brake resistor / brake unit, check mains supply voltage
LUUndervoltageDC bus undervoltage limit reached (< 215 V DC for 230 V unit)Mains supply voltage too low, mains phase failure, power interruptionCheck input mains voltage and fuses, verify mains connection and line supply stability
OHHeatsink OvertemperatureHeatsink temperature threshold exceeded (> 90 °C)Inadequate cooling, fan failure, ambient temperature too high, dirty heatsinkClean heatsink, ensure adequate cabinet ventilation, check cabinet fan operation
OH4Motor OvertemperatureMotor thermal contact or PTC sensor trippedMotor thermal overload, insufficient motor cooling, PTC trip triggered at terminals T1/T2Allow motor to cool down, check motor load and forced ventilation, verify PTC wiring
OH7Heatsink Temperature Warning LevelHeatsink temperature near maximum thresholdHigh ambient temperature, high continuous loadImprove cooling airflow in control cabinet
OH8Motor I2t OverloadMotor calculated thermal load limit reachedContinuous operation at low speed with high motor currentCheck motor current limits, enable forced cooling for motor or resize motor/drive
OCFFast Current Cut-offInstantaneous peak current limit exceededSevere mechanical shock load, short circuit, fast setpoint changes with loose motor connectionCheck mechanical load for jam or binding, inspect motor connections and wiring
P13Power Unit FaultFault detected in internal power section / gate driver circuitInternal hardware failure on inverter power driver board or IGBT moduleInternal hardware fault — power down unit, if fault persists upon restart, return unit for repair or replace inverter
PERProgram Memory ErrorInternal microprocessor memory error / program execution failureInternal micro-controller hardware failure or damaged internal firmware EEPROMInternal hardware fault — perform power cycle, if fault reoccurs, replace the inverter
H05Heatsink Sensor FaultInternal heatsink temperature sensor circuit failureDefective internal temperature sensor hardware or broken internal connectionInternal hardware failure — return unit for service or replacement
EErExternal FaultExternal trip condition triggered via digital input signalExternal monitoring device (e.g. external safety circuit or switch) openedCheck external circuit connected to the digital input programmed for external TRIP
NMAXMax Speed ExceededActual motor speed exceeded maximum speed setting thresholdOverhauling load, improper encoder feedback, improper motor parameter settingsCheck motor control parameters, encoder connection, and braking resistor operation
NSOLLSetpoint Speed FaultSetpoint signal wire break or missing reference signalAnalog input wire break (< 2 mA / 2 V threshold), lost setpoint sourceCheck analog setpoint signal wiring and voltage/current levels
CE0Communication Fault 0Communication failure on fieldbus interface module slotInterrupted fieldbus cable, loose module, fieldbus master stoppedCheck fieldbus wiring, module connection, and fieldbus master status
CE1Communication Fault 1Process data transfer timeout on fieldbus interfaceBus error, master offline, bad shielding/grounding on bus linesCheck fieldbus line termination, shield connection, and master transmission state
CE2Communication Fault 2Parameter data transfer fault on fieldbus interfaceInvalid parameter request sent via fieldbusCheck fieldbus master configuration and parameter telegram format
CE3Communication Fault 3System Bus (CAN) communication errorCAN bus line error, wrong baud rate, missing bus termination resistorCheck CAN bus wiring, 120 ohm line termination, and node IDs
CE4LECOM Communication Time-outTime-out error on RS232/RS485 LECOM interfacePC connection cable disconnected, baud rate mismatch, parameterization software closed unexpectedlyVerify cable connection, serial port settings, and software communication state
Sd1Speed Sensor FaultFault detected in encoder / tachometer signal pathEncoder wire break, incorrect channel phase assignment, encoder power supply faultInspect encoder wiring, shield, supply voltage, and feedback option module
Sd6Motor Stall FaultMotor locked or stalled under heavy loadMechanical blockage, load inertia too high, acceleration time too shortCheck motor mechanism for mechanical obstruction, review torque limits
PR0Parameter Set InvalidSelected parameter set corrupted or emptyPower lost during parameter saving process, incompatible memory contentReload parameter set from GDC backup or reset drive to factory defaults (C0002)
C003EEPROM Memory FaultInternal EEPROM checksum error on parameter loadData corruption in non-volatile memoryPerform factory parameter reset via parameter C0002; if fault persists, replace unit
C013Parameter Set Transfer FaultError during parameter copy between keypad and drive EEPROMKeypad disconnected during transfer, incompatible parameter structureRe-try transfer procedure, verify target drive firmware and power class match

Frequently Asked Questions

How do I transfer parameters to a new Lenze E82EV251-2C drive?

Parameter sets can be copied using the EMZ8211BB XT keypad module, which stores settings in onboard memory for direct transfer to another inverter. Alternatively, parameters can be saved and restored using Lenze Global Drive Control (GDC) software version 4.0 or higher connected via a serial interface.

What do the front-panel LEDs indicate on the E82EV251-2C?

A solid green LED indicates normal enabled operation. Slow green flashing (1 Hz) signifies an inverter inhibit condition, and rapid green flashing (2 Hz) indicates quick stop or setpoint zero mode. A solid red LED signals an active TRIP fault, slow red flashing indicates a warning, and rapid red flashing indicates an active fault with auto-restart pending. If both LEDs are off, input line power is missing or an internal power supply issue exists.

Which fieldbus modules are compatible with the E82EV251-2C?

The E82EV251-2C accepts plug-in modules into its option slot, including the E82ZAFCC010 CANopen module, the E82ZAFPC001 PROFIBUS-DP module, and the E82ZAFSC010 Standard I/O module. It also supports System Bus (CAN) and LECOM serial communications.

How do I clear a PR0 or C003 memory fault?

Parameter corruption errors can be cleared by performing a factory reset using parameter C002 via keypad or GDC software. After resetting the drive, a valid parameter set must be reloaded from a software backup or cloned from an EMZ8211BB XT keypad module.

What is the official successor series for the Lenze 8200 Vector drives?

Lenze recommends the i550 Cabinet Inverter series as the modern migration successor for 8200 Vector drives during system upgrades.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.