Product Information
The Lenze E82EV551_2B is a cabinet-mounted frequency inverter from the 8200 Vector series, engineered to deliver precise speed and torque control for three-phase AC motors rated up to 0.55 kW (0.75 HP). Operating on a supply voltage range of 180 to 264 V AC at 45 to 65 Hz, this compact drive converts incoming single-phase or three-phase power into a controlled 0 to 230 V AC three-phase output. It supports a continuous output current of 3.0 A, with peak acceleration current reaching 4.5 A to handle high-inertia starting conditions. Designated as a variant manufactured without an internal RFI filter, this drive allows panel builders flexibility in configuring external filtering and system EMC architecture within centralized enclosures.
Integrating a replacement unit into an active control system requires matching hardware modules and transferring drive parameters. The E82EV551_2B features a modular construction where control electronics separate from the power unit, enabling insertion of functional modules such as the E82ZAFCC for CANopen or E82ZAFPC for PROFIBUS-DP. Parameter configurations are held in non-volatile memory supporting four distinct parameter sets (PAR1 through PAR4). Setup can be completed using the plug-in E82ZMC memory card for rapid drive cloning, the E82ZBC Keypad XT operator panel, or Lenze Global Drive Control (GDC) software connected via a PC interface. ABC Industrial Parts can assist maintenance teams with fully tested spare units and compatible modules to streamline parameter restoration and commissioning.
System diagnostic data is provided on the drive front panel and through connected diagnostic tools. Dual status indicators—a green Operation LED and a red TRIP LED—display current operational states and fault activity. When a fault is triggered, the inverter disables motor output and logs the event in an internal buffer storing the last four TRIP occurrences. Errors such as OC1 (overcurrent), OU (DC bus overvoltage), LU (DC bus undervoltage), and OH (heatsink overtemperature) typically relate to field wiring, line supply, or mechanical load conditions. Hardware failures like memory corruption (code EE) or excessive internal temperature (code OH7) indicate internal hardware faults where field servicing is not possible, making direct drive replacement or repair through ABC Industrial Parts the most reliable solution to restore production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | E82EV551_2B |
| Model / Type | 8200 Vector |
| Component Type | Frequency Inverter |
| Rated Power | 0.55 kW (0.75 HP) |
| Supply Voltage Range | 180 - 264 V AC |
| Supply Frequency Range | 45 - 65 Hz |
| Mains Rated Current | 6.0 A |
| Output Voltage Range | 0 - 230 V AC (3-phase) |
| Continuous Output Current | 3.0 A |
| Max Acceleration Current | 4.5 A |
| Output Frequency Range | 0 - 480 Hz |
| Switching Frequency | 8 kHz (Adjustable up to 16 kHz) |
| Power Dissipation | 40 W |
| Control Methods | V/f control, Sensorless Vector Control, Vector Control with feedback |
| Enclosure Type | Cabinet-mounted (Without Integrated RFI Filter) |
Programming and Configuration
Parameter management on the Lenze E82EV551_2B is structured around internal EEPROM memory capable of retaining up to four independent parameter sets (PAR1 through PAR4). This allows multi-recipe machine configurations to be stored directly on the drive. Control algorithms can be configured for standard V/f performance, sensorless vector control, or closed-loop vector control depending on application requirements.
Drive configuration can be executed using either the pluggable E82ZBC Keypad XT panel or Lenze Global Drive Control (GDC) engineering software over a serial PC connection. For rapid unit cloning without connecting setup software, the removable E82ZMC memory card provides plug-and-play parameter transfer. Transferring a programmed card into a replacement drive loads all operating parameters instantly. If parameter corruption occurs or a clean setup is required, entering parameter value C0009=1 re-initializes the drive back to factory settings.
Communication and System Integration
The modular construction of the Lenze 8200 Vector series separates core power functionality from network communication interfaces. The E82EV551_2B integrates into industrial networks by attaching fieldbus-specific function modules directly into the front option slot.
Supported communication adapters include the E82ZAFCC CANopen function module and the E82ZAFPC PROFIBUS-DP function module, alongside optional interfaces for DeviceNet and INTERBUS networks. These modules grant master PLCs full control over drive enable, velocity reference commands, real-time operating data, and remote parameter adjustment.
Diagnostics and Status Indication
Real-time diagnostic visual indication is handled via two LED indicators on the inverter faceplate. The green Operation LED indicates general drive status including ready state, active output run, or controller inhibit. The red TRIP LED illuminates solid or flashes when an operational fault causes output shutdown.
Detailed fault analysis is accessible through the E82ZBC Keypad XT display panel or the Global Drive Control software online diagnostic screen. The inverter maintains a non-volatile fault history buffer that logs the last four TRIP conditions to aid in troubleshooting intermittent process interruptions.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| TRIP | Red - Flashing / Solid | Fault condition detected; drive output disabled |
| Operation | Green - Solid / Flashing | Drive status indication (Ready / Operating / Inhibit) |
Replacement and Spare Part Considerations
Before installing a replacement E82EV5512B, confirm that the part number matches the original hardware specifications. Because the '2B' suffix designates a unit built without an internal RFI filter, verify that appropriate external line filters are installed in the control cabinet to maintain required EMC compliance.
When swapping out a damaged unit, remember to transfer all attached function modules, such as the CANopen or PROFIBUS adapter cards, to the replacement chassis. Ensure power is completely isolated before unseating or installing modules.
Commissioning a replacement drive requires reloading application settings. If the original installation utilizes an E82ZMC memory card, transferring the card to the replacement drive copies all parameter sets directly. Alternatively, upload stored parameter backup files via Global Drive Control software or manually program the unit using the Keypad XT module.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short circuit / Overcurrent | Short circuit at motor output or instantaneous overcurrent threshold exceeded. | Short circuit in motor cable or motor winding, excessive acceleration ramp, ground connection error. | Check motor and motor cables for short circuit; check acceleration time settings. |
| OC2 | Earth fault | Ground fault / earth leakage current detected on motor phases. | Ground fault in motor insulation, damaged motor cable, capacitive cable currents due to long cable run. | Check motor windings and supply cables for earth isolation; reduce switching frequency or add output filter. |
| OC5 | Ixt overload (Inverter overload) | Inverter thermal overload threshold reached due to continuous high current. | Drive oversized for load, prolonged operation above continuous rated current I_N, high ambient temperature. | Check mechanical load for jam/binding; check motor sizing and duty cycle; verify cooling fan performance. |
| OU | Overvoltage DC bus | DC bus voltage exceeded upper limit threshold (approx. 400 V DC for 230 V units). | Regenerative load energy during deceleration too high, deceleration time too short, braking resistor missing or defective. | Increase deceleration ramp time; connect braking module and braking resistor if heavy braking duty. |
| LU | Undervoltage DC bus | DC bus voltage fell below lower threshold during operation or standby. | Mains voltage failure, input power dip, phase loss, defective supply fuses or contactor. | Check line supply voltage; verify supply connection and fuses. |
| OH | Heatsink overtemperature | Inverter heatsink temperature exceeds maximum allowable threshold. | Inadequate ventilation, clogged heatsink cooling fins, ambient temperature too high, cooling fan failed. | Clean heatsink cooling fins; verify enclosure fan/ventilation; reduce ambient temperature or carrier frequency. |
| OH4 | Motor thermal overload (PTC) | Motor thermistor/PTC sensor connected to T1/T2 terminals triggered. | Motor overheating due to overload, low speed operation without forced cooling fan, defective sensor cable. | Allow motor to cool; check mechanical load; verify motor external cooling fan. |
| OH7 | Internal device overtemperature | Internal temperature inside inverter housing exceeds safety threshold. | Ambient temperature in control cabinet exceeds limit; internal ventilation failure. | Improve enclosure cooling and airflow; check internal hardware function. If error persists, hardware fault — return unit for service. |
| CE0 | Communication fault - Function module | Communication breakdown between inverter mainboard and installed function module. | Function module loose, poor pin contact, corrupted fieldbus module, EMI noise on fieldbus cable. | Re-seat function module; check shield connections and grounding; inspect module contacts. |
| EE | EEPROM memory fault | Checksum fault or read/write error in internal EEPROM memory. | Data corruption during parameter saving, power drop during saving, internal hardware defect. | Re-initialize drive parameters to factory defaults (load default setting C0009=1); if error remains, internal memory hardware fault — replace inverter. |
| NMAX | Speed threshold exceeded | Motor actual speed exceeded maximum limit parameter C0596. | Incorrect encoder pulses/rev parameter, runaway motor load, tuned gain parameters unstable. | Check motor encoder connections and parameters; tune speed controller gain. |
| P12 | I2t motor overload | Calculated motor thermal overload algorithm triggered. | Motor operated at high load and low speed without external cooling. | Check motor current and load profile; modify I2t monitoring parameters or add external forced fan. |
Frequently Asked Questions
What power rating and supply voltage does the Lenze E82EV551_2B support?
The E82EV551_2B is rated for 0.55 kW (0.75 HP) motors and operates on an AC supply voltage between 180 V and 264 V AC at 45 to 65 Hz. It delivers a continuous output current of 3.0 A to a 230 V three-phase motor.
Does the E82EV551_2B inverter contain an internal RFI filter?
No, the E82EV551_2B model is designed without an integrated RFI filter. Panel installations requiring EMC suppression must incorporate an external mains filter.
How can parameter settings be transferred to a replacement drive?
Parameters can be transferred by moving the plug-in E82ZMC memory card from the original unit into the replacement inverter. Alternatively, settings can be transferred using Lenze Global Drive Control (GDC) software or re-entered manually via the E82ZBC Keypad XT.
Which fieldbus communication interfaces are supported?
The drive supports pluggable communication option modules including the E82ZAFCC CANopen module, E82ZAFPC PROFIBUS-DP module, DeviceNet modules, and INTERBUS modules.
What should I check when an EE fault code occurs?
An EE code indicates an internal EEPROM memory fault. First attempt to clear the memory error by loading factory defaults (setting parameter C0009=1). If the fault does not clear, an internal memory hardware failure has occurred and unit replacement is required.
What is indicated by a red TRIP LED on the front panel?
A solid or flashing red TRIP LED indicates a critical drive fault condition that has disabled power output to the motor. Specific fault codes can be identified using the Keypad XT module or GDC software online diagnostic window.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.