Lenze E82EV551-2C 8200 Vector Frequency Inverter 0.55 kW

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 | Series: 8200 Vector

The Lenze E82EV551-2C is a 0.55 kW frequency inverter from the Lenze 8200 Vector series, engineered for precise motor speed and torque regulation in cabinet-mounted industrial systems. Operating on a single-phase or two-phase 230 V AC supply ranging from 180 V to 264 V AC across 45 to 65 Hz, this compact IP20 unit delivers a continuous output current of 3.0 A with a 150% overload capacity reaching 4.5 A for up to 60 seconds. Designed for high dynamic performance, the drive supports Sensorless Vector Control (SLVC) alongside linear and quadratic V/f characteristic modes, providing adaptable control for standard 4-pole AC asynchronous motors across an output frequency range of 0 to 480 Hz with an 8 kHz switching frequency and 40 W power loss.

Integrating a replacement unit into an existing line requires proper alignment of the drive communication and parameter profiles. The E82EV551-2C features a modular architecture with a Function Module interface (FIF) slot, allowing quick installation of optional fieldbus interface modules including PROFIBUS-DP (E82ZAFPC), DeviceNet (E82ZAFDC), INTERBUS (E82ZAFIC), and LECOM RS232/RS485 (E82ZAFAC). Native networking is supported via terminal block X4 through the integrated CAN system bus at baud rates up to 500 kbit/s. Commissioning a replacement unit requires transferring saved parameters into the drive, which stores two complete parameter sets in its internal non-volatile EEPROM. Using either the optional Keypad XT (E82ZBC) or Lenze Global Drive Control (GDC) software, technicians can clone parameters directly from a donor unit or software backup to restore operation. ABC Industrial Parts provides tested replacement units and technical support to assist with parameter extraction and drive configuration.

System status and operating conditions are indicated on the drive front panel by dedicated status LEDs. A solid green LED confirms the drive output is enabled and ready, while a flashing green LED indicates controller inhibit; a solid red LED indicates an active inverter trip fault, and a flashing red LED signals an active warning. Detailed fault diagnostics can be accessed via parameter C0161 for active trip codes and parameter C0168 for the trip history buffer, viewable using the Keypad XT module or GDC software. First-line troubleshooting should verify mains supply voltage, check motor wiring and ground insulation, inspect cooling fins to prevent heatsink overtemperature, and ensure proper 120-ohm bus termination on CAN system lines. When unresolvable internal faults occur, such as EEPROM memory errors or control board failures, component-level field repairs are not feasible, and installing a tested exchange drive from ABC Industrial Parts offers a fast route back to production.

Technical Specifications

ManufacturerLenze
Part NumberE82EV551-2C
Model / Type8200 Vector
Product Family8200
Component TypeFrequency Inverter
Rated Power0.55 kW
Supply Voltage Range180 - 264 V AC
Continuous Output Current3.0 A
Maximum Output Current4.5 A (150% for 60 s)
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Power Loss40 W
Protection RatingIP20

Programming and Configuration

Parameter setup and drive commissioning for the Lenze E82EV551-2C are carried out using Lenze Global Drive Control (GDC) engineering software or directly through the optional Keypad XT (E82ZBC) pluggable operating module. The drive hardware contains non-volatile EEPROM memory configured to store two independent parameter sets (Parameter Set 1 and Parameter Set 2). This dual-set capability allows technicians to maintain primary operation parameters along with an alternative operating mode or a factory backup configuration directly on the unit.

During replacement procedures, parameter profiles can be copied directly using the Keypad XT parameter transfer function or loaded from a saved PC backup file via GDC software using a LECOM RS232/RS485 module (E82ZAFAC). Essential adjustable parameters include motor nameplate configuration, acceleration and deceleration ramp settings, V/f curve selection, and system monitoring settings. Active fault conditions can be viewed in parameter C0161, while historical events are stored in the trip history buffer at parameter C0168.

Communication and System Integration

The E82EV551-2C inverter includes an integrated CAN system bus interface connected at terminal block X4. Supporting data transmission speeds up to 500 kbit/s, this integrated connection enables multi-drive networking, master-slave synchronisation, and direct process data PDO exchange between interconnected Lenze drives without requiring additional fieldbus hardware.

For integration into broader plant networks, the base drive includes a standard Function Module interface (FIF) slot. Pluggable option modules can be fitted into the FIF slot to interface directly with higher-level controllers. Supported fieldbus options include PROFIBUS-DP (E82ZAFPC), DeviceNet (E82ZAFDC), INTERBUS (E82ZAFIC), and LECOM RS232/RS485 (E82ZAFAC).

Diagnostics and Status Indication

Operational diagnostic feedback on the Lenze E82EV551-2C is provided by two front-mounted status LEDs along with diagnostic parameters accessible via software or keypad interfaces. The status LEDs give immediate visual feedback on power supply presence, drive enablement, warning conditions, and active trip faults.

Detailed fault analysis is supported by parameter C0161, which displays the active trip code, and parameter C0168, which logs historic fault events. These diagnostic parameters can be inspected on the Keypad XT display or monitored in real time using the diagnostic window within Lenze Global Drive Control (GDC) engineering software.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (Ready)Green - Solid/FlashingSolid ON: Drive ready and output enabled. Flashing: Drive ready, output inhibited. OFF: Supply voltage missing or internal power supply failure.
Red LED (Trip)Red - Solid/FlashingSolid ON: Inverter trip fault active. Flashing: Warning or controller inhibit active. OFF: Normal operation without fault.

Replacement and Spare Part Considerations

When replacing an existing Lenze E82EV551-2C drive, matching both hardware and software configurations is vital for successful recommissioning. Ensure the replacement inverter matches the 0.55 kW rating and single/two-phase 230 V input requirement. If the original installation utilizes a communication option such as PROFIBUS-DP or LECOM, remove the option module from the FIF slot of the existing drive and transfer it to the replacement unit.

A replacement drive delivered from stock will contain default parameters and must be parameterized before enabling the motor output. Transfer saved parameters using either the Keypad XT module or GDC software. If terminal X4 system bus networking is utilized, confirm that 120-ohm bus termination resistors are correctly placed at the end nodes. Although Lenze has introduced the i500 series (such as i510 and i550) as modern successors, direct replacement with an E82EV551-2C unit avoids panel mechanical redesigns and software modification.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitInstantaneous overcurrent detection / power output short circuitShort circuit in motor cable, short circuit in motor winding, earth fault, acceleration time set too shortCheck motor cable and motor windings for phase-to-phase short circuits, increase acceleration ramp time, inspect power section. If fault persists with motor disconnected, internal power section failure — return unit for repair.
OC2Earth FaultGround fault / earth current detectedMotor cable insulation breakdown, ground leakage current in motor or wiring, motor cable length too longCheck motor and motor cable for insulation resistance against ground. Inspect motor wiring for ground connection.
OC5I x t Overload during AccelerationExcessive motor load or overcurrent during acceleration phaseMechanical overload during acceleration, acceleration time too short, incorrect motor parameter configurationIncrease acceleration time, reduce mechanical load, verify motor data parameters.
OC6I x t Overload during OperationContinuous current overload during steady-state operationDrive loaded continuously beyond rated current, motor undersized or mechanical jamCheck mechanical load for binding, verify motor sizing, reduce continuous load.
OUOvervoltage DC BusIntermediate circuit DC bus voltage exceeded upper limit (>400V DC on 230V devices)Regenerative energy from motor during deceleration too high, deceleration time set too short, missing or defective brake resistorExtend deceleration time, install or check external brake module/resistor, verify mains supply voltage.
LUUndervoltage DC BusIntermediate circuit DC bus voltage dropped below lower threshold (<215V DC on 230V devices)Mains supply voltage dropped below limit, mains phase loss, mains power outageCheck mains input voltage, check supply fuses and line contactor.
OHHeatsink OvertemperatureDrive heatsink temperature exceeded maximum limit (>90°C)Insufficient cooling airflow, ambient temperature too high, cooling fan failure, excessive dust accumulation on heatsinkClean heatsink cooling fins, ensure adequate cabinet ventilation, check fan operation, lower ambient temperature.
OH4Motor Overtemperature (PTC)Motor temperature sensor trip via PTC/thermal contact terminalsMotor thermal overload, cooling fan failure on motor, PTC wiring openAllow motor to cool down, inspect motor ventilation, check PTC sensor wiring at control terminals.
OH7Motor Temperature Sensor Wire BreakWire break or open circuit detected on motor PTC sensor inputPTC sensor wire disconnected, defective motor PTC sensorCheck wiring to PTC terminals T1 and T2, measure PTC resistance.
Pr1Parameter Set 1 Checksum ErrorInternal EEPROM corrupt or checksum fault in Parameter Set 1EEPROM memory failure, power interruption during parameter writeReload factory default settings or re-download parameter set. Internal hardware/EEPROM defect — return unit for repair if fault cannot be cleared.
Pr2Parameter Set 2 Checksum ErrorInternal EEPROM corrupt or checksum fault in Parameter Set 2EEPROM memory failure, power interruption during parameter writeReload parameter set 2 or perform factory reset. If fault persists, EEPROM hardware error — return unit for repair.
EEREEPROM Read/Write ErrorInternal non-volatile memory access failureInternal control board memory chip defectiveInternal hardware failure — return unit for repair or replace inverter.
E1External Fault 1External fault condition triggered via digital input signalExternal safety circuit or monitoring device opened digital input configured for TRIM-E1Inspect external signal chain, clear external fault source.
E2External Fault 2External fault condition triggered via digital input signalExternal safety circuit or monitoring device opened digital input configured for TRIM-E2Inspect external signal chain, clear external fault source.
CE0System Bus Communication FaultCommunication failure on integrated CAN system busCAN bus wire broken, missing termination resistor, wrong baud rate configuration, master controller timeoutCheck CANbus wiring, verify 120-ohm bus termination resistors at line ends, check baud rate settings.
CE1Function Module Communication Fault (FIF Process Data)Process data time-out between inverter main board and plugged function moduleFunction module loose or defective, fieldbus communication cable disconnectedRe-seat function module in FIF slot, check fieldbus cable and bus master connection.
CE2Function Module Communication Fault (FIF Parameter Data)Parameter data time-out between inverter main board and function moduleFunction module loose or communication interruption during parameter transmissionEnsure function module is securely attached, restart drive.
CE3System Bus Communication Error (Process Data)Process data timeout via CAN system busCANbus master stopped sending process data PDOsCheck master PLC state and CANbus transmission interval.
H05Internal Fault / Control Board DefectInternal hardware self-test failure on control PCBInternal micro-controller hardware error or board component failureInternal hardware failure — non-serviceable. Replace the drive unit or send for service repair.

Frequently Asked Questions

What tools are required to configure parameters on the Lenze E82EV551-2C?

Parameters can be configured using Lenze Global Drive Control (GDC) software via a LECOM adapter module or directly on the unit using the pluggable Keypad XT (E82ZBC) module.

How can parameter settings be transferred to a replacement E82EV551-2C inverter?

Parameter sets saved in internal EEPROM can be transferred to a new drive using the Keypad XT module cloning feature or downloaded via GDC software using a saved project file.

Which fieldbus interfaces are supported by the E82EV551-2C?

The FIF slot supports plug-in modules for PROFIBUS-DP (E82ZAFPC), DeviceNet (E82ZAFDC), INTERBUS (E82ZAFIC), and LECOM RS232/RS485 (E82ZAFAC). Terminal X4 also includes integrated CAN system bus connectivity.

What do the red and green front panel LEDs indicate?

The green LED signals operational readiness (solid ON for enabled, flashing for inhibited). The red LED indicates fault conditions (solid ON for trip fault, flashing for active warning).

How can active and past fault codes be accessed on the drive?

The active fault code is displayed in parameter C0161, and previous trip history is stored in parameter C0168, accessible via Keypad XT or GDC software.

What should be done if fault code H05 or EER is displayed?

Fault code H05 indicates an internal control board failure, while EER indicates an internal EEPROM access fault. These internal hardware defects are not field-serviceable and require drive replacement or professional repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.