Lenze E82EV552_4C 8200 Vector Frequency Inverter 5.5kW

New 
On request
Refurbished   
4 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 | Series: 8200 Vector

The Lenze E82EV552_4C is a 5.5 kW (7.5 HP) frequency inverter from the Lenze 8200 Vector series, engineered for speed and torque regulation of standard three-phase AC induction motors. Operating on a three-phase supply voltage ranging from 320 V AC to 528 V AC at 45 to 65 Hz, this unit delivers a continuous output current of 13 A and operates across an output frequency range of 0 to 480 Hz. The drive supports multiple operating modes including sensorless vector control, open-loop torque control, and configurable linear or quadratic V/f characteristic curves. In ordering codes and part numbers, the wildcard character denotes the cooling mounting style: 'K' designates a standard heatsink unit (E82EV552K4C), 'C' indicates a Cold Plate design (E82EV552C4C), and 'P' represents a push-through mounting variant.

Designed with a modular architecture, the inverter incorporates a plug-in Function Module (FIF) slot that accommodates interchangeable control and fieldbus cards, such as the E82ZAFPC PROFIBUS-DP module or the E82ZAFCC System Bus (CANopen) module. This design allows control modules to be installed or swapped while keeping main field wiring intact. Commissioning a replacement unit requires configuring parameters and installing the matching interface module. The inverter stores up to four independent, switchable parameter profiles in internal EEPROM memory for multi-recipe application demands. Parameters can be backed up or transferred using the optional E82ZBC Keypad XT diagnostic module or Lenze Global Drive Control (GDC) software, with expert parameter extraction from donor drives supported by ABC Industrial Parts when original files are unavailable.

System state and troubleshooting information are provided via front-panel LED indicators and diagnostic parameters. A solid green LED signals active inverter operation, whereas a blinking green LED indicates an initialized drive or ready state without enable. A blinking or solid red LED alerts operators to an active fault or TRIP condition. Real-time operating parameters in the C005x range display DC bus voltage, output current, actual frequency, and heatsink temperature, while code C0168 stores the last four recorded TRIP events. Basic troubleshooting includes inspecting supply voltage, line chokes, motor wiring, and fieldbus connections. When internal microcode, memory, or power stage errors occur, field-level repairs are not recommended, and opting for a tested exchange unit or specialized repair through ABC Industrial Parts provides the fastest resolution.

Technical Specifications

ManufacturerLenze
Part NumberE82EV552_4C
Model / Type8200 Vector Frequency Inverter 5.5 kW
Product Family8200
Series8200 Vector
Component TypeFrequency Inverter
Rated Power5.5 kW (7.5 HP)
Supply Voltage Range320 V AC - 528 V AC (3-Phase)
Supply Frequency Range45 Hz - 65 Hz
Rated Input Current (Without Choke)17 A
Rated Input Current (With Choke)12 A
Continuous Output Current13 A
Peak Output Current (150% Overload)19.5 A (for 60 seconds)
Maximum Output Voltage480 V AC
Output Frequency Range0 Hz - 480 Hz
Switching Frequency8 kHz
Control MethodsSensorless Vector Control, V/f linear, V/f quadratic, Torque Control

Programming and Configuration

Parameterization and commissioning of the Lenze E82EV552_4C frequency inverter are conducted using Lenze Global Drive Control (GDC) software or the plug-in E82ZBC Keypad XT diagnostic panel. Drive response is managed by structured code settings, including acceleration ramp time (C0012), deceleration ramp time (C0013), and rated motor current (C0087).

The internal non-volatile EEPROM memory supports four complete, switchable parameter sets. This functionality allows distinct operating profiles or recipe settings to be toggled dynamically without reloading software parameters from an external controller. Restoring factory defaults across parameters is performed by executing reset code C0002.

Communication and System Integration

The E82EV552_4C utilizes an integrated Function Module (FIF) interface slot that accepts plug-in communication modules. Supported options include the E82ZAFPC PROFIBUS-DP card and E82ZAFCC System Bus (CANopen) module, alongside cards for DeviceNet and LECOM interfaces.

Because field communication and I/O options are housed within the removable FIF module, the base drive can be exchanged without rewiring signal or fieldbus connections. Network timeout monitoring actively tracks cyclically transmitted process data; a loss of fieldbus master communication triggers a CE1 process data error.

Diagnostics and Status Indication

Diagnostic indication on the drive comprises front-panel status LEDs and accessible monitoring codes. Live operating data—such as output current, actual frequency, DC link voltage, and heatsink temperature—can be read via the C005x parameter group. Historical fault tracking is stored in parameter C0168, which retains a log of the last four TRIP occurrences.

Status LED Indicators

LEDColor/StatusMeaning
Red LEDRed - Off / Blinking / SolidOff: Normal operating condition. Blinking/Solid: Fault present or TRIP condition active.
Green LEDGreen - Blinking / SolidBlinking: Drive initializing or ready state without enable. Solid: Drive operating / inverter enabled.

Replacement and Spare Part Considerations

When replacing a Lenze E82EV552_4C inverter, verify the mounting suffix designated by the wildcard character in the full part number. A unit marked 'K' (E82EV552K4C) uses a standard heatsink, 'C' (E82EV552C4C) designates a Cold Plate surface, and 'P' corresponds to a push-through cabinet installation. The replacement unit must match the mechanical cooling method to fit the existing cabinet enclosure.

Ensure the original Function Module (FIF) is transferred to the replacement unit or that an identical card is installed. Parameter files stored in the internal EEPROM must be transferred to the replacement unit using the E82ZBC Keypad XT display panel or Lenze Global Drive Control (GDC) software to maintain system operation.

For long-term migration strategy, the Lenze i550 cabinet frequency inverter serves as the recommended successor line for legacy 8200 Vector drives.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Overcurrent AccelerationShort circuit or excessive output current during motor accelerationMotor cable short circuit, earth fault, acceleration time set too short, motor incorrectly sizedCheck motor wiring and motor insulation, increase acceleration time (C0012), check motor parameter settings
OC2Short Circuit / Overcurrent DecelerationShort circuit or excessive output current during motor decelerationDeceleration time set too short, dynamic braking circuit failureIncrease deceleration time (C0013), check braking resistor/chopper
OC5Overcurrent Constant OperationShort circuit or overcurrent detected during constant speed operationSudden load impulse, mechanical blockage, motor cable shortInspect mechanical load for binding, verify motor parameters and cabling
OUDC Bus OvervoltageIntermediate circuit DC voltage exceeded upper limitExcessive regenerative energy during deceleration, deceleration ramp too short, mains voltage too highExtend deceleration time, connect or inspect external brake resistor / brake chopper, verify input voltage
LUDC Bus UndervoltageIntermediate circuit DC voltage fell below lower thresholdMains supply failure, voltage drop under load, fuse blown, input phase missingCheck mains voltage, verify input fuses and supply connections
OHInverter OvertemperatureHeatsink temperature exceeded permissible maximum limitInadequate cooling, fan failure or clogged heat sink, ambient temperature too high, switching frequency too highClean heat sink, verify fan operation and cabinet ventilation, reduce switching frequency
OH4Motor OvertemperatureThermal motor protection (PTC / thermal contact) activatedMotor overload, continuous operation at low speed without forced cooling, thermal contact cable openAllow motor to cool, verify motor loading, check PTC thermistor wiring on terminals T1/T2
OH7Interior OvertemperatureTemperature inside drive housing exceeded permissible limitExcessive enclosure temperature, fan failureImprove enclosure ventilation, verify internal fan operation
P13Motor I2t OverloadCalculated thermal load of motor exceeded 100% thresholdContinuous motor overload, incorrect motor rated current programmedCheck motor loading, verify C0087 (rated motor current setting)
NMAXSpeed Limit ExceededActual motor speed exceeded maximum configured speed limitUnstable velocity loop tuning, overhauling loadCheck speed controller settings and speed limit parameters
EEREEPROM FaultInternal memory checksum error during power-up or parameter saveElectromagnetic interference during save operation, EEPROM memory failureReload factory default parameters (C0002). Internal hardware fault if error persists after default reset — return unit for repair
E1System Fault E1Internal hardware or microcode control errorInternal electronics failure or severe EMC disruptionInternal hardware fault — power cycle drive; if persistent, return unit for repair
E2System Fault E2Internal hardware timing / control processor errorInternal board component failureInternal hardware fault — return unit for repair
E3System Fault E3Internal communication error between control card and power sectionInternal connector issue or power card hardware defectInternal hardware fault — return unit for repair
E4System Fault E4Internal power supply fault on control boardInternal power supply circuit breakdownInternal hardware fault — return unit for repair
H05Power Stage FaultHardware fault detected inside inverter power sectionIGBT driver defect or damaged output transistor stageInternal hardware fault — replace inverter or return unit for repair
CE1Communication Error Process DataTime-out during process data transfer via function moduleFieldbus master stopped sending data, broken cable, loose function module connectionCheck fieldbus wiring, host controller state, and module seat in FIF slot

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze E82EV552_4C drive?

Parameters can be transferred using the E82ZBC Keypad XT diagnostic panel or Lenze Global Drive Control (GDC) software. Upload the parameter sets from the original inverter or backup file and download them to the replacement unit.

What do the wildcard characters in the E82EV552_4C part number mean?

The wildcard letter indicates the mechanical cooling design: 'K' represents standard heatsink cooling (E82EV552K4C), 'C' denotes Cold Plate mounting (E82EV552C4C), and 'P' identifies a push-through heatsink design.

Which fieldbus modules are supported by the E82EV552_4C?

The inverter accepts plug-in Function Modules (FIF) in its integrated slot, including the E82ZAFPC PROFIBUS-DP card and the E82ZAFCC System Bus (CANopen) module, as well as DeviceNet and LECOM cards.

What causes an OU fault code on the E82EV552_4C inverter?

An OU fault indicates DC bus overvoltage. Common causes include excessive regenerative energy from rapid motor deceleration, a deceleration ramp time that is set too short, or excessively high mains supply voltage.

What is the recommended successor line for the Lenze 8200 Vector series?

The Lenze i550 cabinet frequency inverter line is the official recommended successor series for legacy 8200 Vector frequency inverters.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.