Product Family: 8200 vector | Series: 8200 Vector

The Lenze E82EV751_4C200 is a 0.75 kW frequency inverter from the 8200 Vector series, engineered for precise variable speed and torque control of three-phase AC motors in industrial machinery. Operating on a 3-phase AC supply voltage ranging from 320 V AC to 528 V AC, the drive delivers a continuous output current of 2.4 A at 400 V with a short-time overload capability of 150% rated torque for up to 60 seconds. This specific model variant (suffix 200) is built without an integrated RFI/EMI interference suppression filter, making it suitable for cabinet installations utilizing central external line filters. Motor control capabilities encompass standard V/f characteristic control as well as sensorless vector control across an adjustable output frequency range of 0 Hz to 480 Hz.

Putting a replacement unit into service requires matching the basic drive specification and transferring operational parameters to ensure proper machine function. Operational setups can be replicated using the E82ZMC plug-in memory card, the E82ZBC XT keypad operator module, or PC-based commissioning via Global Drive Control (GDC) software version 3.x or higher. Network integration is handled through the modular AIF/FIF plug-in function slot, which accepts interface modules for CANopen (E82ZAFCC), PROFIBUS-DP (E82ZAFPC), DeviceNet, or INTERBUS fieldbus protocols. Where parameter extraction from a faulty board or donor unit is required, ABC Industrial Parts provides technical support to streamline spare unit commissioning and prevent prolonged downtime.

Diagnostic conditions are shown locally via front-panel green and red LED status indicators. A blinking green LED signifies that the drive is ready with controller inhibit active, while a solid green light indicates active drive operation. Warnings cause the red LED to blink, whereas TRIP faults cause a solid red illumination and shut down the inverter power stage. When a solid red light persists alongside an inactive green LED following a system reboot, internal hardware corruption or component failure is indicated. Because internal hardware errors such as fault code H05 are not field-serviceable, replacing the unit or sourcing a tested exchange drive through ABC Industrial Parts offers a direct path back to full production.

Technical Specifications

Rated Power0.75 kW
Supply Voltage Range320 V AC - 528 V AC
Supply Configuration3-phase
Rated Mains Current2.5 A
Continuous Output Current2.4 A
Maximum Short-Time Output Current3.6 A
Output Frequency Range0 Hz - 480 Hz
Default Switching Frequency8 kHz
Control MethodV/f characteristic control, sensorless vector control
Overload Capacity150% rated torque for 60 seconds
Integrated RFI FilterWithout integrated interference suppression

Programming and Configuration

The Lenze E82EV751_4C200 inverter supports parameter management and system setup through multiple hardware and software interface options. The internal controller features non-volatile memory capable of storing up to four independent, switchable parameter sets. This internal structure allows a single inverter to switch between different operational profiles, motor profiles, or process routines without re-uploading parameters during runtime.

For direct PC configuration and monitoring, the drive connects to Global Drive Control (GDC) software version 3.x or higher. Rapid field replacement without a PC is accomplished using the optional E82ZMC plug-in memory card or the E82ZBC XT keypad operator module. Inserting a pre-programmed E82ZMC memory card transfers parameter sets directly to the drive. If parameter memory corruption occurs, parameter C0002 can be set to 1 to reload factory default parameters before restoring machine-specific settings.

Communication and System Integration

System integration on the Lenze E82EV751_4C200 relies on a modular plug-in function slot utilizing the AIF/FIF interface architecture. This modular design isolates the core frequency inverter hardware from fieldbus physical layers, allowing the unit to adapt to various network topologies by selecting the matching plug-in function module.

Compatible communication hardware includes the E82ZAFCC module for CANopen networks and the E82ZAFPC module for PROFIBUS-DP, alongside optional modules for DeviceNet and INTERBUS systems. The interface handles process data communication, speed references, and host PLC control word signals. Internal diagnostic monitoring continuously checks communication health; a missing or unseated module triggers code CE0, while fieldbus process data timeout triggers code CE1.

Diagnostics and Status Indication

Local operational status monitoring for the E82EV751_4C200 is provided by front-panel green and red status LEDs, supplemented by diagnostic memory parameters. The green LED indicates controller operational states, while the red LED indicates warning or TRIP fault conditions. A solid red LED accompanied by an inactive green LED following power-up points to an unrecoverable internal hardware or processor failure.

In addition to visual LED indicators, full fault history details are stored in the internal TRIP memory register accessible via parameter C0168. Technicians can interrogate code history using the E82ZBC XT keypad or through the diagnostic monitor built into Global Drive Control (GDC) software. Status word inspection over active fieldbus connections also provides continuous diagnostic feedback to higher-level controllers.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (Ready)Green - BlinkingDrive ready, controller inhibited.
Green LED (Ready)Green - Solid ONController enabled / operation active.
Red LED (Fault)Red - BlinkingWarning present.
Red LED (Fault)Red - Solid ONTRIP fault active / Inverter switched off due to error. If solid ON and green off continuously after reboot, indicates possible internal hardware failure.

Replacement and Spare Part Considerations

When replacing an existing Lenze E82EV751_4C200 inverter, maintenance technicians must pay careful attention to the part number suffix. The 4C200 designation specifies a unit manufactured without an internal RFI/EMI interference suppression filter. Installing a variant with different filtering characteristics or installing this unit in a panel lacking external line filtering can affect electromagnetic compliance and system operation.

To complete a drive swap, transfer any existing plug-in function module (such as the E82ZAFCC CANopen or E82ZAFPC PROFIBUS module) from the failed inverter to the replacement unit. Parameter profiles can be transferred directly using an existing E82ZMC plug-in memory card or uploaded via Global Drive Control (GDC) software. For long-term migration planning beyond the 8200 Vector platform, Lenze recommends transitioning to the i550 cabinet inverter series, with model i55AE175F1001000S serving as the direct functional successor.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / Earth faultShort circuit or ground fault detected on motor output terminals.Short circuit in motor cable, earth fault in motor or wiring, output power section defective.Check motor cable and insulation, measure motor winding resistance, check for earth faults.
OC2Overcurrent during accelerationMotor current exceeded maximum threshold during acceleration phase.Acceleration time too short, motor incorrectly dimensioned, mechanical blockage.Increase acceleration time (C0012), check motor load and mechanical system.
OC5I2t OverloadContinuous overload condition triggered I2t motor protection.Drive operated above rated output current for extended duration.Reduce motor load, check drive sizing and parameter C0087.
OUOvervoltage DC busIntermediate circuit voltage exceeded upper trip threshold.Deceleration time too short, regenerative energy from motor too high, mains supply voltage too high.Increase deceleration time (C0013), fit brake chopper / braking resistor, check supply voltage.
LUUndervoltage DC busDC bus voltage fell below minimum allowable operating level.Mains voltage failure, power line drop, supply phase missing.Check mains voltage supply, check fuses and supply connection.
OHHeatsink OvertemperatureInverter heatsink temperature exceeded allowable limit (> 90°C).Ambient temperature too high, fan failure, inadequate cabinet ventilation, excessive switching frequency.Improve cooling/ventilation, clean heatsink fins, check ambient temperature, lower switching frequency.
OH4Motor Over-temperatureThermal switch or PTC thermistor connected to motor sensor terminal triggered.Motor overheated, insufficient motor cooling, PTC trip.Allow motor to cool down, check motor load and external cooling fan.
OH7Motor Thermal Protection (I2t)Motor temperature calculated via software I2t monitoring exceeded limit.Continuous low-speed operation under heavy load without forced ventilation.Check drive load profile, check parameter C0089.
EEEEPROM ErrorInternal EEPROM checksum error or parameter corrupted.Power interrupted during parameter saving, corrupted internal memory.Load factory default settings (C0002 = 1). If error persists, internal control board hardware fault — replace inverter.
EErExternal EEPROM ErrorError reading/writing to external plug-in memory module E82ZMC.Memory module improperly seated or defective.Reinsert memory module E82ZMC or replace memory module.
H05Internal Hardware FaultInverter control unit detected internal hardware corruption or component failure.Internal power supply or processor failure.Internal hardware failure — non field-serviceable. Return unit for repair or replace inverter.
CE0Communication Error Function ModuleLoss of communication between basic drive unit and plug-in function/AIF module.Module loose, improper seating, hardware interface error.Check seating of plug-in module, power cycle drive.
CE1Process Data Communication ErrorFieldbus process data monitoring timeout.Fieldbus cable disconnected, master PLC stopped, incorrect bus address or baud rate.Check fieldbus cabling, master PLC status, and interface configuration.
LPMains Phase FailureFailure or excessive imbalance detected on one input phase.Mains fuse blown, bad connection on one supply phase.Check mains voltage on all three supply lines (L1, L2, L3).

Frequently Asked Questions

Does the Lenze E82EV751_4C200 frequency inverter include an integrated RFI filter?

No, the E82EV751_4C200 variant is manufactured without an integrated RFI/EMI interference suppression filter. External line filtering must be used in the control cabinet.

How are parameters transferred to a replacement E82EV751_4C200 drive?

Parameters can be transferred using the E82ZMC plug-in memory card, an E82ZBC XT keypad operator module, or via a PC running Lenze Global Drive Control (GDC) software version 3.x or higher.

Which fieldbus networks can the E82EV751_4C200 connect to?

The inverter supports fieldbus integration via optional plug-in function modules (AIF/FIF slot), including CANopen (E82ZAFCC), PROFIBUS-DP (E82ZAFPC), DeviceNet, and INTERBUS.

What does a solid red LED indicate on the front panel?

A solid red LED indicates an active TRIP fault that has shut down the inverter output stage. If the red LED remains solid ON and the green LED stays off after a reboot, an unrecoverable internal hardware fault (such as fault code H05) is indicated.

What is the recommended modern replacement for the E82EV751_4C200?

Lenze recommends migrating from the legacy 8200 Vector series to the i550 cabinet frequency inverter series, specifically part number i55AE175F1001000S.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.