Lenze EVF8203-E 8200 Vector Frequency Inverter 1.5kW 230V

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze EVF8203-E is a 1.5 kW frequency inverter belonging to the 8200 vector product family, engineered for precise AC motor speed control and dynamic torque regulation. Designed to operate on a single-phase or three-phase supply voltage between 180 V AC and 264 V AC, this compact drive delivers a rated output voltage of 230 V AC with a continuous output current of 7 A and an input current rating of 13.5 A. Featuring flexible V/f characteristic control and sensorless vector control, the inverter achieves optimal motor performance across an adjustable output frequency range up to 480 Hz at an 8 kHz switching frequency, making it suitable for material handling conveyors, HVAC fans, and centrifugal pumps in IP20 environments.
Connecting and commissioning the EVF8203-E into an existing control system relies on its integrated control terminals, which feature 4 programmable digital inputs, 2 digital outputs, 1 programmable relay output, and 1 analog setpoint input supporting 0-10V, 0-20mA, or 4-20mA signals. An option slot accommodates fieldbus modules such as CANopen (EMF2175IB or EMZ8221WW), PROFIBUS-DP (EMF2133IB), INTERBUS, or LECOM RS-232/RS-485 interfaces. Installing a spare drive is not a simple plug-and-play swap; the new unit requires transfer of operational parameters from internal non-volatile EEPROM memory, which holds up to four switchable parameter sets. Parameter cloning and configuration restoration can be completed using the pluggable Keypad XT (EMZ8201BB) or PC-based software tools including Lenze Global Drive Control (GDC) and EASY Starter, where ABC Industrial Parts can assist in parameter extraction and drive preparation.
Diagnostic feedback on the EVF8203-E is displayed directly through status LEDs, featuring a red Trip/Fault indicator for active faults and a green Ready/Operation indicator for active power stage status. Detailed troubleshooting is supported via fault code readouts on the optional Keypad XT display, live software monitoring via GDC, and internal diagnostic parameters C0161 for the active fault and C0168 for fault history logs. When encountering supply dips or line anomalies, basic checks should confirm incoming line voltage across the 180–264 V AC range, fieldbus cabling, and terminal wiring. Internal electronic failures or corrupted memory conditions, indicated by internal hardware error codes such as H05 or system memory errors like E01, cannot be serviced in the field and require replacing the drive or utilizing expert repair services from ABC Industrial Parts.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | EVF8203-E |
| Model / Type | EVF8203-E |
| Product Family | 8200 vector |
| Component Type | Frequency Inverter |
| Rated Power Output | 1.5 kW |
| Rated Output Voltage | 230 V AC |
| Supply Voltage Range | 180 V AC - 264 V AC |
| Rated Output Current | 7 A |
| Rated Input Current | 13.5 A |
| Maximum Output Frequency | 480 Hz |
| Switching Frequency | 8 kHz |
| Digital Inputs | 4 |
| Digital Outputs | 2 |
| Analog Inputs | 1 |
| Ingress Protection Rating | IP20 |
Programming and Configuration
Programming and parameterization of the Lenze EVF8203-E frequency inverter are managed through software engineering tools or direct interface keypad hardware. The drive supports up to four complete, independently switchable parameter sets stored directly within internal non-volatile EEPROM memory. These multiple parameter sets allow complex machinery to adjust operating profiles dynamically without requiring external software reloads during standard operation.
PC-based setup and parameter transfer are executed using Lenze Global Drive Control (GDC) or EASY Starter software connected via supported communication hardware. For fast field commissioning without a PC, the optional pluggable Keypad XT (EMZ8201BB) connects directly to the drive interface. The Keypad XT allows technicians to modify parameters, upload complete configuration profiles, and clone settings seamlessly from a source drive to a replacement unit, reducing line downtime during drive swaps.
Communication and System Integration
The EVF8203-E integrates into modern control architectures via flexible onboard terminal interfaces and pluggable communication option slots. Standard control wiring includes 4 programmable digital inputs, 2 digital outputs (including a relay output), and 1 analog input. The analog channel accepts standard setpoint signals including 0-10V voltage inputs as well as 0-20mA and 4-20mA current loops, allowing direct speed reference control from analog sensors or system controllers.
Higher-level fieldbus automation is enabled by inserting dedicated interface modules into the drive's integrated option slot. Supported fieldbus options include CANopen modules (EMF2175IB and EMZ8221WW) and PROFIBUS-DP modules (EMF2133IB), alongside INTERBUS and LECOM RS-232/RS-485 serial communication modules. When fieldbus integration is configured, loss of process data triggers specific diagnostic monitoring codes, ensuring rapid response to network dropouts across the bus architecture.
Diagnostics and Status Indication
The Lenze EVF8203-E features clear diagnostic indications designed for fast status assessment and fault tracing. Front panel LED indicators provide instant visual feedback on operational readiness and drive trips. Advanced diagnostics are accessed electronically through parameters C0161, which displays the active fault, and C0168, which logs historic fault events for post-failure analysis.
Detailed fault code messages are rendered on the Keypad XT display (EMZ8201BB) or transmitted in real time over software interfaces like Lenze Global Drive Control (GDC) or EASY Starter. Additionally, digital and relay outputs can be assigned to signaling functions to trip external alarms or notify an upstream PLC during fault conditions.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Trip / Fault Indicator | Red - Solid / Flashing | Indicates active drive fault or trip condition |
| Ready / Operation Indicator | Green - Solid | Inverter power stage is ready or active in normal operation |
Replacement and Spare Part Considerations
Replacing an operational Lenze EVF8203-E requires careful attention to drive parameters and system option modules. Because the 8200 vector series is discontinued by the manufacturer, identifying exact replacement units or evaluating migration paths is critical for maintaining equipment availability. When installing a replacement EVF8203-E, any optional communication module (such as PROFIBUS-DP EMF2133IB or CANopen EMF2175IB) must be moved from the original unit to the replacement inverter slot.
Before putting a spare inverter into service, the existing motor control parameters, switching frequency settings, and digital I/O configurations must be transferred. This is accomplished either by cloning the settings via the Keypad XT (EMZ8201BB) or by restoring a software backup using Global Drive Control (GDC). If migrating to current generation hardware, Lenze recommends the i510 Cabinet series, specifically model i51AE215F10010000S, which requires system reconfiguration and parameter translation.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit / Overcurrent Acceleration | Short circuit at inverter output or excessive acceleration load causing overcurrent. | Short circuit in motor cable, earth fault in motor, acceleration time too short, motor overload. | Check motor cable for short circuit or ground fault, measure motor winding resistance, increase acceleration time (C0012). |
| OC2 | Overcurrent Deceleration | Excessive current during motor deceleration. | Deceleration time set too short, brake chopper not working, extreme mechanical load. | Increase deceleration time (C0013), fit external brake resistor / braking module. |
| OC3 | Overcurrent Constant Operation | Overcurrent during steady-state constant speed operation. | Abrupt load changes, motor mechanical blockage, motor power mismatch. | Inspect mechanical load and motor for mechanical jam or overload, check current limit parameter settings. |
| OU | DC Bus Overvoltage | DC bus voltage exceeds upper threshold limit. | Regenerative energy from motor during deceleration, deceleration time too short, supply voltage too high. | Increase deceleration time (C0013), install braking module and resistor, check mains supply voltage. |
| LU | DC Bus Undervoltage | DC bus voltage dropped below minimum operating limit. | Mains supply failure, supply voltage too low, temporary power dip, mains fuse blown. | Check supply line voltage and fuses, verify mains supply stability. |
| OH | Heatsink Overtemperature | Inverter power stage heatsink temperature exceeded allowable threshold. | Cooling fan defective or blocked, ambient temperature too high, inadequate cabinet ventilation, excessive inverter load. | Clean heatsink cooling fins, check fan operation and cabinet ventilation, reduce ambient temperature. |
| OH4 | Motor Overtemperature (PTC) | Motor temperature sensor triggered overtemperature signal. | Motor thermal overload, cooling fan failure on motor, PTC sensor wire broken or disconnected. | Allow motor to cool down, inspect motor cooling fan, check PTC/thermal sensor wiring connected to terminals T1/T2. |
| OH7 | Inverter Thermal Overload (I x t) | Continuous excessive load on drive inverter exceeded I x t monitoring capacity. | Operating drive continuously above rated current at low switching frequency or heavy load. | Check drive loading, select larger power inverter if required, reduce continuous load. |
| OH8 | Motor Thermal Overload (I2t) | Calculated I2t thermal load for motor exceeded threshold. | Motor running at continuous overload at low RPM without forced ventilation. | Reduce motor load, install external motor cooling fan, verify motor continuous current setting (C0016). |
| CE0 | Communication Error Fieldbus | Interruption of fieldbus process data communication on optional module slot. | Fieldbus cable disconnected, master PLC stopped, incorrect bus address or baud rate. | Check fieldbus cabling and shield grounding, check PLC status, check communication module parameter settings. |
| EEr | External Fault | External fault condition triggered via digital input assigned to TRIP function. | External monitoring device (e.g. pressure switch, safety switch) tripped. | Check external fault circuit connected to programmed digital input terminal. |
| LP1 | Mains Phase Failure | Phase loss detected on AC mains supply line. | One input phase disconnected, loose terminal, blown mains input fuse. | Check input AC voltage on all incoming power terminals, check mains switches and fuses. |
| H05 | Hardware Fault / Internal Fault | Internal electronic hardware fault or internal voltage rail failure. | Internal power supply or gate driver board fault. | Internal hardware fault — return unit for repair or replace inverter. |
| E01 | System Error EEPROM | Internal EEPROM checksum error or memory read failure. | Internal EEPROM corrupt or failed. | Perform factory parameter reset (C0002=6). If fault persists, hardware failure — replace inverter. |
Frequently Asked Questions
What programming software is required to configure the Lenze EVF8203-E inverter?
Configuration can be performed using Lenze Global Drive Control (GDC) software or EASY Starter software. Alternatively, parameters can be adjusted directly without a PC using the pluggable Keypad XT (EMZ8201BB).
Can parameters be copied directly from one EVF8203-E drive to another?
Yes. Parameter sets stored in the non-volatile EEPROM memory can be copied using the pluggable Keypad XT (EMZ8201BB) module or backed up and uploaded via Global Drive Control (GDC) software.
What fieldbus communication modules are supported by the EVF8203-E?
The drive features an option slot supporting fieldbus modules including CANopen (EMF2175IB / EMZ8221WW), PROFIBUS-DP (EMF2133IB), INTERBUS, and LECOM RS-232/RS-485 modules.
How does the drive indicate active faults and operational readiness?
Active state is shown via front status LEDs, where a solid green LED indicates power stage readiness/operation and a solid or flashing red LED indicates a fault or trip condition. Specific error codes are read via Keypad XT or diagnostic parameter C0161.
What recommended replacement or successor drive exists for the EVF8203-E?
While the EVF8203-E can be replaced like-for-like with a spare 8200 vector unit, Lenze recommends the i510 Cabinet series (part number i51AE215F10010000S) as a modern migration successor.
What action should be taken if the drive displays fault code H05 or E01?
Fault code E01 indicates an EEPROM memory checksum failure and can be tested with a factory reset (C0002=6). Fault H05 indicates an internal hardware failure. If E01 persists after a reset or if H05 occurs, the inverter must be returned for hardware repair or replaced.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.