Lenze EVF9326-EV 9300 Vector Frequency Inverter 11 kW

New 
On request
Refurbished   
8 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Series | Series: 9300 Vector

The Lenze EVF9326-EV is an 11 kW frequency inverter belonging to the 9300 Vector series, designed for precise speed and torque regulation of asynchronous AC motors and reluctance motors in high-dynamic industrial applications. Powered by a 3-phase AC supply ranging from 400 V to 480 V, with an operating tolerance range of 320 V to 528 V AC, this drive delivers a continuous rated output current of 23.5 A with an 8 kHz switching frequency and maximum output frequencies up to 480 Hz. Housed in an IP20 cabinet-mount enclosure, this specific variant is configured without an internal RFI interference suppression filter, accommodating customized control panel layouts that utilize centralized external noise filtering.

Integrating the drive into control systems relies on comprehensive onboard I/O and modular expansion interfaces. Physical connections include six programmable digital inputs, four digital outputs, two bipolar analog inputs, two bipolar analog outputs, and a dedicated TRIP fault relay. System-level networking is handled via an integrated CAN system bus or through the plug-in Automation Interface slot, which supports option cards such as PROFIBUS-DP (EMF2133IB), Interbus (EMF2113IB), or LECOM serial modules. Commissioning a spare unit requires transferring operating parameters, which can be completed using Lenze Global Drive Control software or cloned using the Keypad XT (EMF2102IB) module. Because the unit stores up to four parameter sets in non-volatile EEPROM memory, extracting stored parameters or seeking configuration transfer assistance from ABC Industrial Parts helps ensure the spare drive accurately matches original machine settings prior to operation.

Operational monitoring and status feedback are provided through diagnostic LEDs on the front faceplate, the TRIP relay output, and internal memory logs accessible via Keypad XT or software diagnostic windows. Status indications include DRV-RDY for ready state, IMP for active controller inhibit, and TRIP/DRV-ERR for fault alerts. Diagnostic parameter C0183 records fault history to isolate operational trips, such as output short circuits (OC1), DC bus overvoltage (OU), or heatsink overtemperature (OH). Routine field checks should verify mains power phases, motor winding insulation, and cooling airflow. If the drive reports EEPROM errors (EER) or internal self-test failures (H05), internal board faults cannot be serviced in the field; sourcing a fully tested exchange drive or sending the unit to ABC Industrial Parts for repair offers an effective solution to restore production.

Technical Specifications

ManufacturerLenze
Part NumberEVF9326-EV
Model / Type9300 Vector
Product Family9300 Series
Component TypeFrequency Inverter
Rated Power11 kW
Nominal Supply Voltage3x 400 / 480 V AC
Supply Voltage Range320 - 528 V AC
Rated Output Current23.5 A
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Protection RatingIP20
RFI SuppressionWithout internal RFI filter
Programmable Digital Inputs6
Programmable Digital Outputs4
Bipolar Analog Inputs2
Bipolar Analog Outputs2
Fault Relay Output1 (TRIP relay K11/K12/K14)

Programming and Configuration

Parameter management for the Lenze EVF9326-EV inverter is performed either through local display hardware or PC-based programming tools. Engineering setup and real-time monitoring are supported via Lenze Global Drive Control (GDC) software, which allows users to view diagnostic logs, tune motor parameters, and save project configurations. For field setup without a PC, the optional Keypad XT (EMF2102IB) plugs directly into the front panel to provide parameter access and cloning features.

The inverter contains non-volatile EEPROM memory capable of storing up to four complete parameter sets. Diagnostic monitoring parameters, including operating status parameter C0051 and fault history log C0183, allow technicians to evaluate performance and historical trip events. When transferring configurations to a new unit, factory settings can be restored via code C0002 before uploading the stored project data or transferring settings using terminal strips and memory cloning.

Communication and System Integration

The EVF9326-EV comes standard with an integrated CAN system bus accessible via control terminals X4 and X5. This interface enables high-speed inter-drive communication, allowing direct multi-axis drive networking, dynamic speed synchronization, and coordinated master-slave controller operations across drive lines without requiring external gateway hardware.

For integration into broader industrial fieldbus networks, the drive features a plug-in Automation Interface (AIF) slot. This slot accommodates modular communication cards, including PROFIBUS-DP (EMF2133IB), Interbus (EMF2113IB), and LECOM serial interface modules. Proper fieldbus operation requires verifying module seating, node address switches, and network line termination resistors.

Diagnostics and Status Indication

Drive status and operational health are indicated through three LEDs located on the front faceplate alongside a dedicated TRIP fault relay (terminals K11/K12/K14). Further diagnostic depth is available via the Keypad XT display panel or through the Global Drive Control software oscilloscope and error log windows, which reference parameter C0183 for detailed fault recording.

Status LED Indicators

LEDColor/StatusMeaning
DRV-RDYGreen - SolidDrive status / ready for operation
IMPYellow - SolidPulse inhibit / controller inhibit active
TRIP / DRV-ERRRed - Solid/FlashingFault / active error status

Replacement and Spare Part Considerations

When swapping a damaged Lenze EVF9326-EV drive, matching the exact part number suffix is necessary. The EV designation identifies this unit as an inverter constructed without an internal RFI filter. Replacing this unit with a variant containing an integrated filter may affect cabinet dimensions or interference control schemes.

To minimize replacement downtime, the EVF9326-EV features plug-in control terminal strips, allowing wiring assemblies to be detached without disconnecting individual signal wires. Before powering on the replacement inverter, ensure that parameter sets are loaded via Global Drive Control software or cloned using the Keypad XT module, and confirm that any optional AIF fieldbus modules are securely transferred into the option slot.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit at the inverter output power terminals (U, V, W)Motor winding short circuit, motor cable damaged, ground fault, acceleration time too shortCheck motor cable and motor insulation; check acceleration time settings; if fault persists with motor disconnected, internal inverter hardware fault — return unit for repair
OC2Earth FaultGround fault / earth fault at the inverter outputMotor cable capacitance too high, ground leakage in motor or cableCheck motor cable for phase-to-ground short, check motor insulation with megohmmeter
OC5I x t OverloadContinuous motor overload limit exceeded (I x t integration threshold)Drive operated above rated current for prolonged time, mechanical jam, wrong motor data setCheck mechanical load for blockage; check motor parameters in drive configuration; reduce load
OUOvervoltage DC BusDC bus voltage exceeded maximum safety limit (approx. 770 V DC)Regenerative energy from motor during deceleration; deceleration time too short; missing or failed brake chopper/resistorExtend deceleration time (ramp down); install or check braking resistor and brake chopper
LUUndervoltage DC BusDC bus voltage fell below minimum operation threshold (approx. 400 V DC)Mains supply supply voltage failure, supply phase missing, mains supply drop under loadCheck supply voltage, fuses, and main contactor; verify all 3 input phases are present
OHHeatsink OvertemperatureHeatsink temperature exceeded maximum safety threshold (approx. 85°C / 90°C)Inadequate control cabinet cooling, ambient temperature too high, fan failure, dirty heatsink finsClean heatsink fins, check cabinet fan and airflow, verify internal heatsink fan operation
OH1Heatsink Temperature HighHeatsink temperature warning threshold exceededHigh ambient temperature, heavy load, clogged cooling channelImprove cooling, clean heatsink, reduce load
OH3Motor OvertemperatureMotor temperature sensor trip (PTC or KTY connected to terminals T1/T2)Motor thermal overload, insufficient motor cooling, defective temperature sensor or broken wireAllow motor to cool down, check motor load and cooling fan, check sensor wiring on T1/T2
OH4Inverter Interior OvertemperatureAmbient / internal control board temperature inside drive too highControl cabinet temperature excessive, internal air circulation blockedCheck enclosure air conditioning and ventilation
OH7Motor Temperature Sensor Wire BreakOpen circuit / broken wire detected on motor temperature sensor circuit (T1/T2)Cable disconnected, wire break, defective PTC/KTY sensorInspect motor temperature sensor cable and connections
NMAXOverspeed ExceededActual motor speed exceeded maximum configured speed limitIncorrect speed controller tuning, field weakening failure, encoder signal disturbanceCheck speed controller parameters, verify encoder wiring and shield connection
EEREEPROM ErrorInternal EEPROM memory checksum error during parameter read/writeElectromagnetic interference during parameter store, corrupt internal memory, hardware memory defectRe-load factory default parameters (C0002) and write back project parameters; if fault persists, non-field-serviceable board failure — replace unit
PR0Program Error 0Internal system software execution / task overflow faultInternal firmware execution error or corrupted configuration memoryPerform power cycle; re-download parameter set; if fault recurs, internal hardware fault — replace inverter
PR1Program Error 1Internal processor system exceptionProcessor logic fault or control board interferencePower cycle unit; if persistent, internal hardware failure — return unit for repair
H05Internal Hardware FaultHardware self-test failed during initialization or runtimeInternal board component failure, power supply circuit faultInternal hardware failure — not field serviceable. Unit must be replaced or returned for repair
CE0Communication Error AIFCommunication failure between inverter main controller and AIF moduleAIF communication module not seated properly, bad fieldbus connection, defective moduleCheck seating of AIF module in option slot; check fieldbus cabling and termination resistors
CE1CAN System Bus ErrorCANbus error state active / bus-off status on system bus (X4/X5)Incorrect baud rate setting, missing line termination resistors (120 Ohm), damaged bus lineVerify CAN wiring, check bus termination switches/resistors, verify node ID and baud rate settings

Frequently Asked Questions

How are parameter sets transferred when replacing a Lenze EVF9326-EV?

Parameter configurations can be downloaded using Lenze Global Drive Control (GDC) software or cloned directly between units using the plug-in Keypad XT (EMF2102IB) memory module. The inverter supports up to four parameter sets stored in internal EEPROM memory.

Does the EVF9326-EV inverter include an integrated RFI filter?

No, the EVF9326-EV model is designed without an internal RFI interference suppression filter. It is intended for installation in control enclosures that utilize centralized external noise suppression.

What fieldbus communication options are compatible with the EVF9326-EV?

In addition to the standard onboard CAN system bus (terminals X4/X5), the drive features an Automation Interface (AIF) slot that supports plug-in modules including PROFIBUS-DP (EMF2133IB), Interbus (EMF2113IB), and LECOM.

What steps should be taken if the inverter reports fault code H05 or EER?

Fault code H05 indicates an internal hardware self-test failure, and EER signifies an EEPROM memory checksum failure. If resetting parameter defaults via C0002 does not resolve code EER, or if code H05 appears, an unserviceable internal hardware fault exists requiring unit repair or replacement.

What do the front panel status LEDs on the EVF9326-EV signify?

A solid green DRV-RDY LED indicates the drive is ready for operation, a solid yellow IMP LED shows pulse inhibit is active, and a solid or flashing red TRIP/DRV-ERR LED signals an active fault condition.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.