Lenze EVF9329-EVV004 9300 Vector Frequency Inverter 45 kW 89A

New 
On request
Refurbished   
5 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Vector

The Lenze EVF9329-EVV004 is a 45 kW frequency inverter from the 9300 Vector series designed for precise three-phase AC motor control in demanding industrial environments. Delivering a continuous rated output current of 89 A over an input supply range of 320 to 528 V AC, this drive supports flexible control modes including open-loop V/f, sensorless vector, and closed-loop vector control with encoder feedback. As a V004 variant, the unit is constructed without an internal radio interference filter, allowing machine builders and system integrators to implement external EMC filtering matched to specific cabinet and installation requirements.

Control and network integration are facilitated through plug-in terminal blocks and dedicated interface options. The inverter features an integrated CANopen system bus on terminal block X4 for drive networking at speeds up to 500 kbit/s, along with a plug-in Automation Interface slot that accepts expansion cards for fieldbus protocols such as PROFIBUS-DP, DeviceNet, INTERBUS, and EtherCAT. Control connections include 5 digital inputs, 2 digital outputs, 2 analog inputs, and 2 analog outputs, alongside motor thermal protection terminals and a relay output. When swapping or commissioning a replacement drive, parameter settings must be transferred to mirror the original application. The inverter stores up to four complete parameter sets in non-volatile EEPROM memory, which can be configured or loaded using Lenze Global Drive Control software or a Keypad XT unit. ABC Industrial Parts can assist in sourcing and preparing replacement units to ensure seamless system integration.

System status and operating faults are communicated directly through front-panel LEDs and diagnostic interfaces. Three status LEDs indicate state: a green LED for RUN status, a red LED for TRIP fault conditions, and a yellow LED indicating warning thresholds for current, voltage, or thermal limits. Detailed fault codes such as OC1 short-circuit detection, OU overvoltage, or OH heatsink overtemperature can be monitored via the Keypad XT module, the Global Drive Control online diagnostic window, or the internal fault history log. Initial troubleshooting should verify supply voltage across line terminals, motor insulation, control terminal connections, and cooling airflow across the heatsink. If internal hardware faults such as H05 or EEPROM communication errors occur, board-level failures are not field-serviceable, making drive repair or a tested exchange unit from ABC Industrial Parts the quickest route back to production.

Technical Specifications

ManufacturerLenze
Part NumberEVF9329-EVV004
Model / Type9300 Vector Frequency Inverter (Variant V004)
Product Family9300 Vector
Component TypeFrequency Inverter
Rated Power45 kW
Continuous Output Current89 A
Supply Voltage Range320 - 528 V AC
Maximum Output Frequency600 Hz
Nominal Switching Frequency8 kHz
Digital Inputs5
Digital Outputs2
Analog Inputs2
Analog Outputs2
Integrated System BusCANopen (Terminal X4, up to 500 kbit/s)
EMC / RFI FilteringWithout integrated interference filter (V004 variant)

Programming and Configuration

Parameter management for the Lenze EVF9329-EVV004 frequency inverter is executed through dedicated hardware tools and software engineering utilities. Drive parameterization can be performed directly at the cabinet using the plug-in Keypad XT (EMF2171IB) or remotely via a PC connection using Lenze Global Drive Control (GDC) software and a PC System Bus Adapter (EMF2177IB). Keypad XT provides clear display readouts and full parameter menu access for rapid commissioning, setpoint adjustments, and diagnostic monitoring without requiring a computer.

The inverter incorporates non-volatile EEPROM memory capable of holding four complete internal parameter sets. These parameter sets store motor calibration curves, control mode selections, I/O terminal assignments, acceleration ramps, and fieldbus configuration settings. During machine setup, multiple parameter sets allow pre-configured operational profiles for different products or operating modes, while providing an internal backup that preserves drive configuration during power outages.

When replacing a unit in the field, parameter sets can be uploaded from an existing drive or backup file via Global Drive Control software and downloaded into the replacement unit. Ensuring that motor data and operational parameters match the original drive profile is essential for maintaining dynamic vector performance and preventing trip conditions upon restart.

Communication and System Integration

The EVF9329-EVV004 provides comprehensive fieldbus and system networking capabilities to integrate into automated control systems. Standard drive-to-drive communication and parameterization are managed via an integrated CANopen system bus interface accessible on terminal block X4. Operating at transmission speeds up to 500 kbit/s, the CANopen bus allows fast cross-communication between Lenze drives and centralized PLC masters.

For integration into broader industrial automation networks, the drive features a dedicated plug-in Automation Interface (AIF) slot. This expansion slot accommodates modular fieldbus communication cards, including the Lenze PROFIBUS Module (EMF2133IB) and Lenze EtherCAT Module (EMF2192IB), as well as option modules for DeviceNet and INTERBUS. Installing an AIF module enables seamless cyclic control and direct parameter access over plant-wide fieldbus networks without modifying the core drive hardware.

Local control wiring connects through plug-in terminal blocks designed for rapid wiring and maintenance. The interface provides 5 digital inputs, 2 digital outputs, 2 analog inputs, and 2 analog outputs. Dedicated connections are also provided on terminal block X5 for a TRIP relay contact and on terminal X10 for motor thermal monitoring using PTC sensors or thermal contacts.

Diagnostics and Status Indication

Visual status indication on the front panel of the EVF9329-EVV004 allows immediate assessment of operational state and active faults. Three status LEDs convey drive conditions: a green LED (RUN) indicates ready, enabled, or initializing states; a red LED (TRIP) signals an active fault or trip condition; and a yellow LED alerts operators when current, voltage, or thermal warning thresholds have been reached.

Advanced diagnostic functionality is accessible using the optional Keypad XT or via the Global Drive Control (GDC) online diagnostic window. The drive maintains an internal non-volatile fault history log that records trip conditions for post-fault analysis. Additionally, hardwired fault signalling is supported through the potential-free TRIP relay contact output on terminal block X5, which can trigger emergency stop circuits or upstream controller alarms.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (RUN)Green - Solid / FlashingSolid = drive ready or operating; Flashing = drive enabled or initializing
Red LED (TRIP)Red - Solid / FlashingDrive trip or active fault condition
Yellow LEDYellow - SolidWarning or operating limit reached (current, voltage, or thermal threshold)

Replacement and Spare Part Considerations

When replacing an existing drive with a Lenze EVF9329-EVV004, it is crucial to verify the exact variant suffix. The V004 specification designates a hardware variant engineered without an internal radio interference filter. If the existing installation relies on an external RFI line filter, ensure that the external filter remains installed and operational. Installing a V004 drive in a system expecting an integrated EMC filter without external filtering may cause electromagnetic interference issues.

Before placing a spare drive into service, the parameter set from the original unit must be loaded into the new inverter. Transferring parameters can be accomplished by saving the parameter set to a PC via Global Drive Control software using the PC System Bus Adapter (EMF2177IB) or transferring saved sets via the Keypad XT module. If an optional fieldbus communication card (such as PROFIBUS EMF2133IB or EtherCAT EMF2192IB) is present, transfer the card from the original unit to the plug-in AIF slot and verify node address settings.

Physical replacement involves verifying power input line voltages (320 to 528 V AC) and ensuring proper output phase sequence to the motor. Inspect plug-in control terminals for secure seating and verify that thermal protection wiring on terminal X10 and trip relay connections on terminal X5 are correctly terminated.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Earth FaultInstantaneous overcurrent during acceleration or short circuit on motor terminalsShort circuit in motor cable, winding short circuit, acceleration ramp time too shortCheck motor wiring and motor insulation resistance; increase acceleration time; check drive current sensor
OC2Earth Fault / Deceleration OvercurrentEarth fault or overcurrent during deceleration phaseEarth fault in motor circuit, deceleration time too short, braking module defectiveCheck motor and wiring for ground faults; increase deceleration time; check brake chopper
OC5I x t OverloadContinuous overload threshold exceeded (inverter thermal protection triggered)Drive undersized for load, prolonged operation above continuous current ratingReduce motor load, check operating cycle, check drive current rating
OUDC Bus OvervoltageDC bus voltage limit exceededExcessive regenerative energy during deceleration, braking resistor not connected or defectiveExtend deceleration ramp time, verify connection and resistance of external braking resistor
LUDC Bus UndervoltageDC link voltage dropped below lower thresholdMains supply failure, voltage dip, loose power connectionCheck supply voltage, input fuses, and mains connections
OHHeatsink OvertemperatureInverter heatsink temperature exceeds maximum allowable thresholdInadequate ventilation, cabinet cooling fan failure, heatsink clogged with dirtClean heatsink fins, check control cabinet fan operation and ambient airflow
OH4Motor Temperature FaultMotor temperature sensor trip (PTC or thermal contact opened)Motor overheating due to overload or restricted coolingCheck motor mechanical load, cooling fan, and PTC connections at terminal X10
OH7Internal Drive OvertemperatureTemperature inside the drive housing exceeds limitInternal fan failed or cabinet temperature too highCheck cabinet internal cooling; internal hardware fault requires unit service if fan circuit fails
LP1Mains Phase FailurePhase missing on AC line inputBlown line fuse, bad connection on one phase of incoming supplyCheck line supply voltages and input line fuses
EE0EEPROM Communication ErrorData corruption or communication loss with internal memory during power-up or writeInternal EEPROM chip failure or corrupted memory blockAttempt factory reset and parameter reload; persistent error indicates internal control board failure requiring factory service/replacement
CE0AIF Communication ErrorCommunication interruption between inverter and plug-in AIF fieldbus moduleAIF module loose, fieldbus cable broken, bus master timeoutCheck seating of AIF module, check fieldbus cabling and master status
H05Internal Hardware ErrorUnrecoverable internal control hardware faultControl board malfunction or internal power supply failureNon-field-serviceable failure — replace the inverter unit or contact Lenze service

Frequently Asked Questions

What does the V004 designation mean on the Lenze EVF9329-EVV004?

The V004 variant indicates that this 9300 Vector inverter is supplied without an internal radio interference (RFI) filter. External EMC filters must be installed in the control cabinet if required by local EMC standards.

Which software is used to configure and back up the EVF9329-EVV004?

The drive is programmed and configured using Lenze Global Drive Control (GDC) software connected via a PC System Bus Adapter (EMF2177IB), or locally using the plug-in Keypad XT (EMF2171IB).

How many parameter sets can be saved internally on the drive?

The EVF9329-EVV004 stores up to four complete, independent parameter sets in non-volatile internal EEPROM memory.

Which communication protocols are supported by this inverter?

The inverter includes a built-in CANopen interface on terminal block X4 (up to 500 kbit/s). Optional protocols such as PROFIBUS-DP (EMF2133IB), EtherCAT (EMF2192IB), DeviceNet, and INTERBUS can be added using plug-in module cards in the Automation Interface (AIF) slot.

What should be checked if the drive reports fault code H05 or EE0?

Fault code H05 indicates an internal hardware failure, and EE0 indicates an EEPROM communication or memory corruption error. If attempting a factory reset and parameter reload does not resolve the error, the internal control board has failed and requires unit replacement or repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.