Lenze EVS9321-EPV004 9300 Servo Position Controller 0.37kW

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300

The Lenze EVS9321-EPV004 is a 0.37 kW servo position controller from the Lenze 9300 Servo series, engineered for precise dynamic motion control of synchronous and asynchronous AC servo motors. Operating on a 320 V AC to 528 V AC main supply with a rated output current of 1.5 A and a 24 V DC control supply, this compact drive incorporates an internal target position profile generator, touch-probe indexing, and flexible homing logic. The EP positioning variant executes motion profiles locally on the drive, reducing execution load on higher-level controllers in packaging, automated assembly, material handling, and textile machinery.

Interfacing the EVS9321-EPV004 into a machine setup relies on dedicated feedback and network connectors, including resolver feedback at connector X7, incremental or SinCos encoder feedback at connector X8, and an integrated CAN System Bus interface at connector X4 operating at up to 500 kbps. The front panel includes an Automation Interface (AIF) slot designed to accept option modules such as PROFIBUS-DP (EMF2133IB or EMF2111IB), DeviceNet, INTERBUS, or LECOM serial adapters, as well as the Operating Module Keypad XT (EMF2102IB). Commissioning a spare unit requires matching network address switches, setting baud rates, and loading parameter profiles using Global Drive Control (GDC) software or transferring parameter backups via Keypad XT memory. Engineering support from ABC Industrial Parts can assist maintenance teams with parameter transfers and network verification to get replacement units operational rapidly.

Diagnostic oversight is provided on the front panel by three status LEDs: Green (DRIVE READY) indicating drive enable or ready status, Red (TRIP) signaling an active fault state, and Yellow (IMP) confirming pulse inhibit on the power output stage. Detailed diagnostic data, including an eight-event error history log with operating hour timestamps, can be accessed via Keypad XT or GDC software to resolve common issues such as overcurrent (OC1), DC bus overvoltage (OU), system bus errors (CE0), or positioning following errors (P01). When diagnostic logs indicate unrecoverable internal failures such as power stage output faults (H10), internal thermal sensor damage (H11), or EEPROM corruption (EER), board-level field repair is not viable, making a tested replacement or repair service through ABC Industrial Parts the most effective route to restore production.

Technical Specifications

ManufacturerLenze
Part NumberEVS9321-EPV004
Model / Type9300 Servo Position Controller
Component TypeServo Controller
Product Family9300 Servo
Rated Power Output0.37 kW
Supply Voltage Range320 - 528 V AC
Control Supply Voltage24 V DC
Rated Output Current1.5 A
Peak Output Current (60s)2.25 A
Max Short-Time Current (0.5s)3.0 A
Power Dissipation40 W
Switching Frequency8 kHz
Max Output Frequency480 Hz
Digital Inputs8
Digital Outputs4
Analog Inputs2
Analog Outputs2

Programming and Configuration

Programming and parameter configuration for the Lenze EVS9321-EPV004 are executed using Global Drive Control (GDC) software or directly via the pluggable Operating Module Keypad XT (EMF2102IB). Keypad XT allows field technicians to monitor parameters and execute parameter commands, such as parameter code C0002 for restoring factory defaults or saving modified profile sets directly to internal non-volatile drive memory.

The EP variant of the 9300 Servo series includes integrated target positioning software logic, touch-probe indexing, and customizable homing routines. When commissioning a spare unit, drive parameters must be loaded from a saved profile backup into parameter code C0002 to match motor feedback types, current limits, positioning lag limits (C0254), and ramp times (C0012/C0013).

Communication and System Integration

System integration on the EVS9321-EPV004 is facilitated by the integrated Lenze System Bus (CAN interface) on connector X4, enabling cross-communication between drives and master-slave axis synchronization at rates up to 500 kbps. Correct bus line termination with 120-ohm resistors at both ends and valid CAN node address selection are required for continuous network operation.

For high-level fieldbus integration, the unit features a front Automation Interface (AIF) slot. This slot accepts option modules including PROFIBUS-DP (EMF2133IB / EMF2111IB), DeviceNet, INTERBUS, or LECOM RS232/RS485 adapters, integrating the drive into centralized master PLCs.

Diagnostics and Status Indication

The drive provides hardware status monitoring via three front panel LEDs. The Green (DRIVE READY) LED blinks when the drive is ready but inhibited, and turns solid when fully enabled and operational. The Red (TRIP) LED indicates an active fault condition, while the Yellow (IMP) LED signals pulse inhibit on the output power stage.

Extended diagnostics are available through GDC software or Keypad XT parameter C0168. The drive stores up to eight fault events in a non-volatile error buffer complete with operating hour timestamps, simplifying fault identification during machine troubleshooting.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP)Red - SolidFault or TRIP condition present. Controller is inhibited due to active error.
Green LED (DRIVE READY)Green - Blinking / SolidBlinking = Controller ready / Controller inhibit active; Solid = Controller enabled / operating normally.
Yellow LED (IMP)Yellow - SolidPulse inhibit active (power stage outputs disabled).

Replacement and Spare Part Considerations

When replacing an existing drive with a spare Lenze EVS9321-EPV004, ensure the part number matches the EP positioning variant and 0.37 kW / 1.5 A rating. Installing a non-EP model will result in missing target positioning profile logic and homing routines required by the machine program.

Before powering up the replacement unit, transfer any front AIF fieldbus option module (such as PROFIBUS-DP EMF2133IB / EMF2111IB) from the original drive, verify terminal wiring and 120-ohm CAN termination resistors, and load the parameter set via GDC or Keypad XT to mirror motor feedback and axis positioning settings.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / OvercurrentShort circuit or excessive ground current during accelerationShort circuit in motor cable, inter-turn short in motor, excessive acceleration rampCheck motor and wiring for short circuit / ground fault; check acceleration time (C0012)
OC2Overcurrent during DecelerationOutput current exceeds threshold during braking rampDeceleration time too short, braking energy too highIncrease deceleration time ramp (C0013), verify braking module / resistor operation
OC5I x t OverloadPower stage overloaded continuouslyContinuous overload, motor undersized for application, mechanical bindingCheck mechanical drive train for stiffness, verify motor power sizing
OUDC Bus OvervoltageDC bus voltage exceeds upper threshold (>770 V DC)Excessive regenerative energy, deceleration ramp too fast, braking resistor defective or disconnectedCheck braking resistor connection and value; increase deceleration time
LUDC Bus UndervoltageDC bus voltage dropped below threshold (<370 V DC / 285 V DC)Supply mains failure, input phase missing, mains voltage too lowCheck mains line voltage, check supply fuses and line contactor
OHHeatsink OvertemperatureHeatsink temperature exceeds 85°C / 90°CInsufficient cabinet cooling, heatsink dirty, fan defective, ambient temperature too highClean heatsink fins, check enclosure fan and ventilation space
OH3Motor Overtemperature (PTC)Motor thermal sensor triggered at terminals T1/T2Motor overheated due to sustained overload or insufficient motor coolingAllow motor to cool down, check motor load and forced-cooling fan
OH7Motor Temp Sensor Wire BreakOpen circuit in motor thermal sensor wireDisconnected sensor cable or defective KTY/PTC sensorCheck wiring between drive terminals T1/T2 and motor thermal sensor
OH8I2t Motor Load Warning/TripCalculated motor load limit reached via I2t thermal modelExtended low-speed operation under heavy loadReduce continuous motor torque requirement or add external motor cooling fan
OS1OverspeedActual motor speed exceeded maximum thresholdSpeed controller unstable, encoder wiring issue, overhauling loadTune speed controller gain (C0070, C0071), verify encoder/resolver shielding and connections
CE0System Bus (CAN) Communication ErrorCommunication failure on integrated CAN interface X4Bus cable broken, incorrect baud rate, missing termination resistorCheck CAN cabling, 120 Ohm termination resistors at both ends, and node address settings
CE1AIF Communication ErrorCommunication fault between drive and optional fieldbus module in AIF slotModule disconnected, loose connection, fieldbus master stoppedCheck seating of AIF fieldbus module, verify PLC/master state
CE2AIF Time-Out ErrorTime-out during process data transfer via AIF slotPLC controller went into Stop state or fieldbus cable disconnectedCheck fieldbus master status and network cabling
CE3CAN Time-Out ErrorProcess data transfer time-out on System Bus CANTransmitting peer node offline or network interruptedCheck status of master/peer drive on CAN bus
CE4CAN Bus-Off StateCAN controller entered Bus-Off state due to excessive transmission errorsWrong baud rate, noise interference, bad shielding, open bus lineCheck shield grounding, line termination, and CAN baud rate configuration
EEREEPROM Memory ErrorInternal EEPROM checksum error on power-up or parameter savePower interrupted during parameter saving or internal memory failureReload factory default parameters (C0002 = 11); internal hardware fault — return unit for repair if error persists
rE0Resolver Fault (X7)Loss of resolver signal on connector X7Resolver cable disconnected, broken wire, bad pin connectionCheck resolver cable, shielding, and connector X7 pin connections
rE1Incremental/SinCos Encoder Fault (X8)Encoder signal track failure or cable break on X8Track A/B signal loss or power supply failure to encoderCheck encoder wiring, power supply, and track signals
LP1Motor Phase FailureMissing output phase to motorMotor wire disconnected, output contactor openCheck wiring on terminals U, V, W to motor
P01Following Error Exceeded (Pos-Lag)Positioning lag between command profile and actual position exceeds limit C0254Mechanical axis binding/jam, acceleration ramp too aggressive, position controller gain too lowCheck mechanical movement, adjust position controller gain (C0254) or error tolerance window
P02Positive Limit Switch ReachedHardware or software positive limit switch actuated during motionAxis moved past maximum permitted rangeClear limit switch input and jog axis back into valid working zone
P03Negative Limit Switch ReachedHardware or software negative limit switch actuated during motionAxis moved past minimum permitted rangeClear limit switch input and jog axis back into valid working zone
P05Homing / Referencing ErrorHoming routine failed to complete or reference switch signal lostReference switch defective, homing direction wrong, switch missed during searchVerify homing switch wiring, homing speed, and reference search parameters
H10Internal Power Stage Output FaultInternal driver/power module failure in power sectionInternal component breakdown or output transistor shortInternal hardware fault — return unit for repair
H11Internal Thermal Sensor ErrorInternal heatsink temperature sensor open or shortedInternal sensor hardware damageInternal hardware fault — return unit for repair

Frequently Asked Questions

What software is required to configure the Lenze EVS9321-EPV004?

The drive is configured using Global Drive Control (GDC) software or directly via the Operating Module Keypad XT (EMF2102IB).

Can a standard 9300 servo drive replace the EVS9321-EPV004?

No, the EP suffix indicates the positioning controller variant featuring internal profile generation, homing logic, and touch-probe functions. A standard non-EP drive lacks these positioning capabilities.

How are parameters transferred from a faulty drive to a replacement unit?

Parameters can be exported from the original drive using GDC software or copied using a Keypad XT module (EMF2102IB) and written to the replacement drive via parameter code C0002.

What do the status LEDs on the front panel indicate?

The Red LED (TRIP) signals an active fault, the Green LED (DRIVE READY) indicates controller operational or ready status, and the Yellow LED (IMP) indicates pulse inhibit on the output power stage.

What does fault code CE0 mean on the EVS9321-EPV004?

Fault code CE0 indicates a System Bus (CAN) communication error on connector X4, caused by cable damage, incorrect baud rate configuration, or missing line termination resistors.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.