Lenze EVS9322-EKV004 9300 Servo Cam Profiler Controller

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Series | Series: 9300 Servo Cam Profiler

The Lenze EVS9322-EKV004 is a 0.75 kW servo controller from the 9300 Series, specifically configured as a 9300 Servo Cam Profiler. Operating on a mains supply voltage range of 320 V AC to 528 V AC at 45 to 65 Hz, this IP20 panel-mount drive delivers a continuous output current of 2.5 A with a peak current capacity of 3.75 A for dynamic acceleration phases. Built for precise multi-axis positioning and electronic camming applications, the unit integrates specialized motion profiling capabilities directly into the drive hardware, eliminating the need for mechanical cam assemblies or external high-speed motion controller cards.

Interfacing the EVS9322-EKV004 with automated machinery relies on its onboard CAN system bus, dual expansion slots, digital and analog I/O terminals, and resolver feedback on connector X7. Commissioning a replacement unit requires transferring machine-specific parameters and electronic cam profile tables, as a factory-fresh unit will not operate machine motion without prior setup. Parameter sets and cam tables stored in non-volatile memory can be restored using Lenze Global Drive Control (GDC) software version 4.x or higher, or copied directly using the optional EMF2102IB XT keypad module. When parameter extraction from a damaged drive or existing storage media is required, ABC Industrial Parts can assist in preparing replacement drives for fast installation.

Diagnostic information on the drive state is provided via front-panel status LEDs and software monitoring tools. A solid green LED indicates controller enable and drive readiness, whereas a flashing green LED signifies an inhibited controller or warning condition; a solid or flashing red LED signals a TRIP fault state. Detailed fault entries can be evaluated through the TRIP memory log using Lenze GDC software or the XT keypad, giving precise causes for errors such as heatsink overtemperature (OH), DC bus overvoltage (OU), or communication loss (CE0/CE1). Initial troubleshooting should focus on input power stability, 120 Ohm CAN bus termination, resolver feedback cabling on connector X7, and fieldbus module seating in Slot A. If hardware self-test faults such as H05 occur, internal component failure cannot be serviced on site, making drive replacement or expert repair through ABC Industrial Parts necessary to restore production.

Technical Specifications

ManufacturerLenze
Part NumberEVS9322-EKV004
Model / Type9300 Servo Cam Profiler
Product Family9300 Series
Component TypeServo Controller
Rated Output Power0.75 kW
Rated Continuous Current2.5 A
Peak Output Current3.75 A
Supply Voltage Range320 - 528 V AC
Mains Frequency45 - 65 Hz
Output Voltage0 - Mains Voltage V AC
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Digital Inputs4
Digital Outputs2
Analog Inputs2
Analog Outputs2
Onboard System BusCANbus (10 - 500 kbps)
Enclosure RatingIP20

Programming and Configuration

Configuring the Lenze EVS9322-EKV004 servo drive is executed through Lenze Global Drive Control (GDC) software version 4.x or higher, connected via the system bus interface or diagnostic adapter. GDC software enables engineers to build, recalculate, and modify complex electronic cam profile tables, set operating parameters, and configure drive control structures for application-specific task execution.

The drive features internal non-volatile EEPROM storage capable of retaining up to four independent parameter sets alongside custom motion profile data tables. For field-level adjustments or parameter transfers without a computer, the pluggable Lenze EMF2102IB XT keypad module allows maintenance personnel to upload, download, and store complete parameter sets directly at the cabinet panel.

Communication and System Integration

System communication for the Lenze EVS9322-EKV004 centers around an integrated CAN system bus supporting data transmission rates from 10 kbps up to 500 kbps. This onboard network facilitates inter-drive synchronization, master frequency coupling, and multi-axis speed or position coordination across complex machine setups without external motion controller cards.

To integrate into higher-level plant automation networks, the drive includes dual expansion slots. Slot A accepts pluggable fieldbus automation modules such as the EMF2133IB PROFIBUS-DP module, DeviceNet modules, or INTERBUS options. The dual-slot layout allows simultaneous fieldbus control and local function expansion, ensuring compatibility with diverse PLC architectures.

Diagnostics and Status Indication

The EVS9322-EKV004 incorporates dual LED indicators on the front panel alongside diagnostic software routines for rapid status verification. The green status LED indicates operational readiness when solid and controller inhibition or warning conditions when flashing. The red status LED illuminates or flashes upon detecting active fault conditions or TRIP states.

Detailed diagnostic records are maintained in an internal TRIP memory log accessible through the Lenze GDC Diagnostic Window or the EMF2102IB XT Keypad Module. The controller also supports diagnostic output signaling by assigning internal TRIP or fault status bits to physical digital outputs or relay contacts for external PLC alarm integration.

Status LED Indicators

LEDColor/StatusMeaning
Red LEDRed - Solid or FlashingIndicates a fault condition or TRIP state
Green LEDGreen - Solid or FlashingSolid indicates controller enable and drive ready; Flashing indicates controller inhibited or warning state

Replacement and Spare Part Considerations

When replacing a failed Lenze EVS9322-EKV004 drive, ensure the replacement unit matches the exact part number and functional variant code (V004), as hardware variants differ in internal motion capabilities and software processing modules. Physical mounting dimensions and terminal layout match standard 9300 Series IP20 units of identical frame size.

A replacement unit must be loaded with the machine's parameter set and electronic cam profile tables before powering up the drive outputs. Parameters can be restored from a software backup using Lenze GDC software V4.x+ or transferred directly from a donor unit using an EMF2102IB XT keypad module.

Verify that option modules in Slot A (such as an EMF2133IB PROFIBUS-DP module) are correctly transferred and firmly seated in the replacement unit. Ensure the CAN system bus line is terminated with 120 Ohm resistors at both physical ends of the bus to prevent communication errors such as CE1 upon startup.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OHHeatsink Temperature HighDrive heatsink temperature has exceeded maximum permissible limit (> 90 °C).Inadequate cooling, fan failure, ambient temperature too high, continuous excessive overload.Check cabinet ventilation, clean cooling fins, verify ambient temperature is within range, inspect internal fan.
OH4Motor Temperature Switch OpenMotor thermal contact or PTC thermistor circuit triggered.Motor overheating, thermal contact open (terminals T1/T2), motor sensor wire disconnected.Allow motor to cool down, check motor load, verify wiring on terminals T1/T2.
OUDC Bus OvervoltageDC bus voltage has exceeded upper threshold limit (~800 V DC).Excessive regenerative energy during deceleration, deceleration time set too short, missing or defective brake resistor.Increase deceleration times, inspect braking module and braking resistor, verify mains input voltage.
LUDC Bus UndervoltageDC bus voltage dropped below minimum operating limit (~400 V DC).Mains voltage supply failure, phase loss, power drop under load.Check mains voltage input, inspect fuses, check power connections and supply transformer.
OC1Short Circuit / Earth FaultInstantaneous overcurrent trip triggered by short circuit or ground fault.Short circuit in motor cable, motor winding fault, earth/ground fault on output terminals U/V/W.Check motor and output wiring for insulation resistance and short circuits. If fault persists with motor disconnected, internal power stage failure - return unit for repair.
OC2Overcurrent during AccelerationOutput current exceeded peak limit during motor acceleration.Acceleration ramp set too steep, motor mechanically blocked, incorrect motor data.Increase acceleration time, check motor for mechanical binding, verify motor parameters.
OC5Ixt OverloadDrive load integral (Ixt overload) exceeded allowable threshold.Continuous operation above rated current (between 100% and 150% load).Reduce mechanical load, select larger servo controller size if process requires continuous high torque.
CE0Communication Fault - Automation ModuleInterruption of data transfer to fieldbus module in Slot A.Loose module connection, fieldbus cable damaged, master PLC offline.Inspect fieldbus plug and connections, verify master PLC status, check module seating in Slot A.
CE1Communication Fault - CAN System BusCANbus line fault or communication timeout on integrated system bus.CAN line broken, missing terminating resistors (120 Ohm), baud rate mismatch, high bus traffic.Verify bus cables, check presence of termination resistors at both ends of CAN bus, confirm baud rate settings.
EE0EEPROM Memory ErrorInternal EEPROM checksum error or data corruption during parameter save.Power failure during save operation, corrupt memory block.Load factory default settings and reload parameter backup. If error persists, internal hardware fault — replace or repair unit.
H05Internal Hardware FaultInternal self-test failed on control board.Internal electronic components failure.Internal board failure — field repair not possible. Replace unit or send to repair center.
P12Resolver Signal FaultLoss or corruption of resolver feedback signal on connector X7.Resolver cable damaged or disconnected, defective resolver sensor in motor, incorrect feedback configuration.Check resolver cable wiring and connector X7, test resolver windings for continuity.
PR0Program / Cam Profile ErrorError in calculated cam trajectory profile or illegal profile data.Invalid cam table data programmed, master position jump out of range.Verify cam profile structure in Lenze GDC software, recalculate and re-download cam profile tables.

Frequently Asked Questions

What software is needed to program the Lenze EVS9322-EKV004?

The EVS9322-EKV004 is programmed and configured using Lenze Global Drive Control (GDC) software version 4.x or higher, or adjusted locally using an EMF2102IB XT keypad module.

Can the parameter settings be transferred without a PC?

Yes, parameter sets can be uploaded and downloaded directly at the drive using an optional Lenze EMF2102IB XT keypad module.

What causes fault code OH on the EVS9322-EKV004 drive?

Fault code OH indicates high heatsink temperature exceeding 90 °C, caused by restricted cabinet ventilation, fan failure, high ambient temperature, or continuous excessive overload.

What fieldbus networks are supported by the EVS9322-EKV004?

In addition to its built-in CAN system bus, the drive supports fieldbus communication via expansion modules, including PROFIBUS-DP (such as module EMF2133IB), DeviceNet, and INTERBUS.

How do I resolve a CE1 communication fault on the EVS9322-EKV004?

CE1 indicates a CAN system bus fault. Check the bus cabling, verify that 120 Ohm terminating resistors are installed at both ends of the CAN bus line, and confirm matching baud rates across all devices.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.