Lenze EVS9322-EPV004 9300 Servo Positioning Controller 0.75kW

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo

The Lenze EVS9322-EPV004 is a 0.75 kW servo positioning controller from the Lenze 9300 Servo family, designated under model code EVS9322-EP. Operating across a 3-phase AC supply voltage range of 320 V to 528 V at 45 Hz to 65 Hz, this compact drive unit delivers a continuous output current of 2.5 A with a peak output current capability of 3.75 A for demanding acceleration phases. Designed for high-accuracy dynamic positioning and motor speed regulation, the drive powers synchronous and asynchronous AC servomotors in applications such as packaging machinery, automated assembly systems, web handling, and machine tools.

Physical connectivity features a dedicated 9-pin D-sub resolver feedback input at interface X7 alongside TTL/RS422 incremental encoder input and output connections at interface X8 supporting signal frequencies up to 500 kHz. System integration relies on an integrated CAN system bus using CANopen protocols up to 500 kbit/s, while a 33-pin Automation Interface slot accepts plug-in fieldbus modules. Commissioning a replacement unit requires transferring saved configurations from internal EEPROM memory—which holds up to four parameter sets—or uploading parameters via Lenze Global Drive Control software or the Keypad XT module. When replacing a failed unit, matching hardware specs and transferring existing option cards are vital steps, and technical support from ABC Industrial Parts can assist in ensuring precise configuration backup and restoration.

Diagnostic monitoring on the EVS9322-EPV004 is handled via front panel status LEDs, where the green Operation LED signals controller enable status and the red TRIP LED indicates a active fault state. Advanced diagnostic monitoring includes code C0183 for immediate active TRIP codes and code C0168 for a fault history log storing the last four fault events with timestamps. Keypad XT display menus and GDC software provide direct visibility into operating states and common system trips such as overvoltage, undervoltage, or feedback errors. Internal hardware defects or microprocessor failures are non-field-serviceable, making a tested replacement drive from ABC Industrial Parts the standard solution for minimizing machine downtime.

Technical Specifications

ManufacturerLenze
Part NumberEVS9322-EPV004
Model / TypeEVS9322-EP
Product Family9300 Servo
Component TypeServo Positioning Controller
Rated Power Output0.75 kW
Supply Voltage Range320 - 528 V AC
Supply Frequency45 - 65 Hz
Continuous Output Current2.5 A
Maximum Output Current3.75 A
Rated Mains Current2.5 A
Switching Frequency8 kHz
Maximum Output Frequency480 Hz
Power Loss70 W
Digital Inputs4
Digital Outputs2
Analog Inputs2
Analog Outputs2
Integrated FieldbusCANopen / CAN System Bus

Programming and Configuration

The Lenze EVS9322-EPV004 servo positioning controller is commissioned and configured using Lenze Global Drive Control (GDC) software or via the optional plug-in Keypad XT module (EMZ9371BC / EMF2102IB). Parameterization defines operational parameters including dynamic position control loops, velocity profiles, feedback response, and motor characteristics, alongside mapping the four digital inputs, two digital outputs, two analog inputs, and two analog outputs.

To simplify machine servicing and parameters backup, the drive houses internal non-volatile EEPROM memory capable of retaining up to four complete parameter sets. This internal storage enables fast parameter backup and restore operations without needing continuous external power. During unit replacement, saved configuration files can be uploaded using GDC software or copied via the Keypad XT module to ensure full parameter alignment with the target machine.

Communication and System Integration

System networking on the EVS9322-EPV004 is anchored by an onboard CAN system bus interface operating on CANopen protocols at transmission rates up to 500 kbit/s. This integrated interface allows rapid peer-to-peer data exchange between multiple servo drives, supporting synchronized multi-axis control, electronic shafts, and distributed motion topologies across complex automation lines.

For integration into broader plant networks, the unit features a 33-pin Automation Interface (AIF) slot designed to accept plug-in option cards. Supported communication options include the EMF2133IB PROFIBUS-DP card and EMF2175IB DeviceNet module, as well as INTERBUS and LECOM serial interface cards. Network addresses, baud rates, and fieldbus parameters are managed directly within the drive parameters.

Diagnostics and Status Indication

Operational diagnostic indicators on the front panel of the EVS9322-EPV004 consist of two primary LEDs. A green Operation LED signals controller enable status and operational readyness, while a red TRIP LED alerts maintenance staff to active fault states.

In-depth diagnostic monitoring is accessed using the Keypad XT display or the GDC software diagnostic tool. Active error codes are displayed under parameter C0183, while parameter C0168 provides access to a non-volatile fault history log storing the last four TRIP events with timestamps for fault tracking.

Status LED Indicators

LEDColor/StatusMeaning
TRIPRed - Solid / FlashingFault state indicator
OperationGreen - Solid / FlashingController enable and operational state indicator

Replacement and Spare Part Considerations

When replacing an existing Lenze drive with a spare EVS9322-EPV004, confirm that the power rating matches 0.75 kW and the continuous current rating corresponds to 2.5 A. Verifying that input power matches the 3-phase 320 V to 528 V AC specification prevents potential hardware damage or line protection trips upon power-up.

Before applying power to the replacement unit, any plug-in expansion module installed in the original controller's Automation Interface (AIF) slot—such as a PROFIBUS or DeviceNet card—must be unseated and reinstalled into the replacement unit. Additionally, parameter sets must be restored from backup via GDC software or loaded from the Keypad XT module to ensure correct feedback loop parameters, I/O assignments, and positioning setups.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit on output phases or ground faultShort circuit in motor cable or motor windings; cable capacitance too highCheck motor cable and motor for phase-to-phase or phase-to-ground short circuits. Check motor insulation.
OC2Earth Fault / Ground FaultGround fault on output phaseGround fault in motor lead or motor insulation breakdownCheck motor wiring and insulation to ground.
OC5I*t OverloadDrive loaded above rated continuous current limit for extended timeExcessive continuous mechanical load, stalled motor, undersized driveReduce load, check machine mechanics for blockages, check sizing of motor and drive.
OUDC-Bus OvervoltageDC bus voltage exceeds upper threshold limitBraking energy returned to drive too high; deceleration ramp too short; brake resistor defective or not connectedExtend deceleration time, connect external brake resistor, check brake chopper circuit.
LUDC-Bus UndervoltageDC bus voltage dropped below minimum operating limitMains supply failure, supply voltage drop, phase lossCheck mains voltage supply, check line fuses and main switch.
OHHeatsink OvertemperaturePower section heatsink temperature exceeded maximum safety thresholdInadequate cooling, fan blocked or defective, ambient temperature too highClean heatsink, check cabinet ventilation and internal drive fan operation.
OH3Motor Overtemperature (PTC)Motor temperature sensor reported overtemperature tripMotor thermal overload, cooling fan failure on motor, incorrect PTC sensor connectionAllow motor to cool down, check motor load and forced-cooling fan, verify PTC sensor connections at terminal T1/T2.
OH7Internal Drive OvertemperatureDrive internal ambient/board temperature too highControl cabinet temperature excessiveImprove cooling inside control cabinet.
CE0Communication Error AIFInterrupted communication between controller and module in AIF slotLoose fieldbus module connection, defective module or interferenceCheck fieldbus module seated correctly in AIF slot, check grounding and shield connection.
CE1System Bus (CAN) Communication ErrorCANbus line fault or node timeoutBus cable broken, incorrect baud rate, missing termination resistorCheck CAN bus wiring, shield connection, terminal resistors (120 Ohm), and node addresses.
EErInternal EEPROM FaultData corruption or read/write failure in internal non-volatile EEPROM memoryInternal hardware fault, power interruption during parameter write cycleInternal hardware error — re-initialize parameters to factory default. If error persists, return unit for repair/replacement.
H05Internal Hardware ErrorInternal board component or controller microchip failure detected during self-testInternal circuit defectInternal hardware fault — non-field-serviceable. Replace drive or contact manufacturer service.
NMAXSpeed Limit ExceededMotor speed exceeded maximum permissible limit threshold (C0596)Speed controller loop instability, incorrect feedback resolution parameter, overspeed conditionCheck speed controller gains, resolver/encoder setup, and speed limit configuration.
Sd1Resolver FaultResolver signal loss or open circuit detected at X7 interfaceResolver cable disconnected, broken wire, defective resolverCheck resolver wiring, connector X7 seating, and resolver insulation.
Sd2Incremental Encoder FaultEncoder signal track failure or missing pulse train at X8 interfaceEncoder cable defect, power supply failure to encoder, loose connectorCheck encoder cable, connectors, and encoder supply voltage settings.
LP1Mains Phase FailureFailure of one or more incoming AC mains power linesBlown fuse, broken line supply cable, supply asymmetryCheck incoming mains lines L1, L2, L3 and line protection devices.

Frequently Asked Questions

What software and accessories are used to parameterize the Lenze EVS9322-EPV004?

The drive is parameterized using Lenze Global Drive Control (GDC) software or the plug-in Keypad XT operator module (EMZ9371BC / EMF2102IB). Up to four parameter sets can be stored directly in the unit's internal non-volatile EEPROM memory.

How are fieldbus communication capabilities added to the EVS9322-EPV004?

Fieldbus networking is enabled via the built-in 33-pin Automation Interface (AIF) slot, which accepts plug-in cards such as the EMF2133IB for PROFIBUS-DP or EMF2175IB for DeviceNet, alongside INTERBUS and LECOM communication cards.

Which motor feedback interfaces are available on the EVS9322-EPV004 controller?

The controller includes a 9-pin D-sub resolver interface at connector X7 and a TTL/RS422 incremental encoder input/output interface at connector X8 supporting signal frequencies up to 500 kHz.

How do you view active fault codes and trip history on the drive?

Active TRIP fault codes are viewed under code C0183 using the Keypad XT display or GDC software. The fault history log, which stores the last four TRIP events with timestamps, is accessed under code C0168.

What corrective actions are recommended when fault code Sd1 occurs?

Fault code Sd1 indicates a resolver signal loss or open circuit at interface X7. Inspect the resolver cable, verify connector X7 is firmly seated, and test the resolver windings and wiring insulation.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.