Lenze EVS9323-ESV004 EVS9323-ES V004 1.5 kW Servo Controller

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300

The Lenze EVS9323-ESV004 is a 1.5 kW servo controller from the Lenze 9300 Servo series, designed for dynamic positioning and multi-axis motion control in automated manufacturing. Operating on a 3-phase mains supply from 320 V AC to 528 V AC (400/480 V AC nominal), this unit provides a rated continuous output current of 3.9 A with a peak output capability of 5.9 A for high-torque acceleration phases. Featuring the cold-plate mounting configuration (V004 variant), the controller direct-couples to an external cooling plate or heatsink surface, reducing heat accumulation within the IP20-rated enclosure and allowing for compact control panel footprints in packaging, material handling, and printing machinery.

System integration relies on integrated interfaces and modular expandability to match existing machine architectures. Feedback devices connect via dedicated terminals, including resolver feedback on connector X7 and universal encoder signals—such as TTL, SinCos, and Hiperface—on connector X8. Inter-drive synchronization and network motion control are handled via the onboard CAN system bus operating at speeds up to 500 kbit/s, while Slot A accepts fieldbus communication cards such as the Lenze EMF2133IB PROFIBUS module or EMF2192IB EtherCAT module. Replacing an existing unit requires transferring saved motor parameters, gain settings, and bus configurations using the Global Drive Control (GDC) software or a pluggable EMZ9371BC operating keypad, a process where ABC Industrial Parts can assist with pre-configured replacement drives or parameter transfer support.

Real-time operational monitoring and fault diagnosis are facilitated through front-panel LEDs and diagnostic registers. The unit features three LED status indicators: a green Ready light for operational status, a red Fault light indicating an active trip condition, and a yellow IMP light signaling pulse inhibit. Detailed fault logs are maintained in parameters C0168 and C0170, accessible via the GDC software or keypad, while analog outputs on terminals X3/1 and X3/2 allow direct monitoring of drive variables. Initial troubleshooting should verify 3-phase mains supply levels, DC bus voltage within the 460 V DC to 740 V DC range, CAN bus line termination, and feedback cable integrity. When persistent hardware errors or internal component failures occur, ABC Industrial Parts provides tested exchange units and repair services to restore machine operation without extended delay.

Technical Specifications

ManufacturerLenze
Part NumberEVS9323-ESV004
Model / TypeEVS9323-ES V004
Product Family9300 Servo
Component TypeServo Controller
Rated Power1.5 kW
Supply Voltage3x 400 / 480 V AC
Supply Voltage Range320 - 528 V AC
Rated Output Current3.9 A
Maximum Output Current5.9 A (150% overload for 60 s)
DC Bus Voltage Range460 - 740 V DC
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Mounting TypeCold-plate technology
Protection RatingIP20
Integrated FieldbusCAN system bus / CANopen (500 kbit/s max)

Programming and Configuration

Commissioning and parameter adjustment for the Lenze EVS9323-ESV004 are primarily performed through Lenze Global Drive Control (GDC) software or the plug-in EMZ9371BC keypad unit. The controller features four internal non-volatile parameter sets, allowing multiple operating configurations to be saved directly on the unit. These memory banks store motor map data, speed controller tuning values, positioning profiles, and input/output assignments.

When deploying a replacement controller, parameter settings must be restored from a backup or transferred from the original unit. Using GDC software, parameter files can be uploaded from an existing drive and downloaded directly into the spare unit over the CAN bus interface or serial keypad link. Alternatively, the pluggable EMZ9371BC keypad allows manual parameter copying between identical drives. Reverting to factory settings can be executed at any time by loading parameter set command C0002.

Communication and System Integration

The EVS9323-ESV004 includes an integrated CAN system bus running CANopen protocol at transmission rates up to 500 kbit/s. This bus interface enables fast, multi-axis synchronization and cross-communication between drives without requiring additional network cards. Proper bus topology requires a 120 Ohm termination resistor fitted at both physical ends of the CAN network line to prevent communication errors.

For higher-level network integration, the unit features a modular Slot A extension port. This port accepts optional fieldbus cards, such as the Lenze EMF2133IB PROFIBUS module or EMF2192IB EtherCAT module, as well as InterBus expansion options. Feedback integration is supported across two dedicated physical interfaces: connector X7 handles resolver signals, while connector X8 accommodates digital incremental or absolute feedback systems using TTL, SinCos, or Hiperface protocols.

Diagnostics and Status Indication

The front panel of the EVS9323-ESV004 features three LED indicators that give immediate visual feedback regarding the operational state of the drive. The green Ready LED signals normal operational readiness, the red Fault LED illuminates when an active fault condition triggers a drive trip, and the yellow IMP LED shows that pulse inhibit is active, keeping the power output stage disabled.

Advanced diagnostic tools are available via parameters C0168 and C0170, which hold the historical fault memory log. Technicians can view detailed error codes and trip events using the EMZ9371BC keypad or through the diagnostic window in Global Drive Control (GDC) software. Additionally, programmable analog output terminals X3/1 and X3/2 provide real-time hardware signal monitoring for external meters or oscilloscope inspection.

Status LED Indicators

LEDColor/StatusMeaning
ReadyGreen - Solid/FlashingController operational status / Ready for operation
FaultRed - SolidDrive fault trip active
IMPYellow - SolidPulse inhibit active

Replacement and Spare Part Considerations

When replacing an EVS9323-ESV004 drive, ensure the replacement unit carries the matching V004 cold-plate designation. Standard 9300 series drives with integrated air heatsinks use different mechanical mounting dimensions and cooling requirements, making direct physical swap-outs impossible without panel modification. Proper thermal paste or flat surface seating against the cabinet cold plate must be maintained during installation to prevent thermal tripping.

Before applying power, transfer any option modules installed in Slot A (such as EMF2133IB or EMF2192IB) from the failed unit to the spare drive. Verify that terminal block connections, feedback cables on X7/X8, and 3-phase power lines are firmly seated. Parameter settings must be transferred using GDC software or the EMZ9371BC keypad to align motor feedback types, current limits, and CAN bus node ID settings with the host control system.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuitPower section short circuit or earth fault detectedShort circuit in motor cable, motor winding fault, excessive capacitive cable loadCheck motor and wiring for short circuits or insulation breakdown. If fault persists with motor disconnected, internal inverter stage failure (return unit for repair).
OC2Earth faultGround short circuit current detectedEarth fault in motor phase cable or motor housing insulation breakdownMeasure insulation resistance of motor and power cables. Check grounding system.
OC5I x t overloadInverter continuous overload limit exceededDrive operated above rated continuous current for extended period, mechanical stall or heavy frictionCheck mechanical load, process acceleration times, and current limits.
OUOvervoltage DC busDC bus voltage exceeds maximum threshold limit (~770 V DC)Excessive regenerative energy during deceleration, brake chopper inactive or braking resistor open/undersizedCheck deceleration ramps, verify braking resistor connection and resistance value.
LUUndervoltage DC busDC bus voltage dropped below minimum operating limit (~460 V DC)Mains supply failure, blown supply fuse, input phase missing, mains voltage dipCheck mains voltage input levels, fuses, and power connections.
OHHeatsink overtemperatureHeatsink temperature exceeds maximum allowable thresholdCold plate surface cooling inadequate, ambient temperature too high, fan failure (if external module present)Check thermal contact of cold plate mount, cooling medium, heat sink clean environment.
OH4Heatsink sensor errorHeatsink temperature sensor circuit open or short circuitInternal temperature sensor failure or broken PCB traceInternal hardware failure — return unit for repair.
LPPhase failureMains phase failure detectedOne supply phase missing or severely unbalanced supply voltageCheck supply line voltages and supply wiring across all 3 phases.
NMAXSpeed threshold exceededActual motor speed exceeded maximum configured speed limitControl loop instability, incorrect speed controller tuning, driving loadCheck feedback encoder connections and speed controller gain settings.
SD2Resolver faultResolver signal loss or broken wire detected on connector X7Resolver cable unplugged, damaged shield, broken core, or damaged resolver sensorCheck connector X7 and resolver feedback cable wiring continuity.
SD3Encoder faultIncremental/absolute encoder signal fault on connector X8Faulty encoder cable, missing supply voltage, or corrupted absolute track dataVerify encoder connection at X8, signal levels, and cable shielding.
CE0Communication fault CANSystem bus CAN communication error or bus-off stateCAN bus wiring short circuit, incorrect termination resistors (120 Ohm missing at line ends), baud rate mismatchCheck CAN bus wiring, termination resistors, and baud rate parameters.
CE1Automation module errorCommunication fault between drive controller and plug-in module in Slot AModule not properly seated, external fieldbus network interrupted, module failureCheck module seating, fieldbus cabling, and external network master.
EEREEPROM errorInternal EEPROM checksum or non-volatile memory read/write failureInternal memory corruption or hardware memory IC failureReload factory default settings (C0002). If error persists, internal memory failure — return unit for repair.
H05Internal faultHardware failure detected during power-on self testInternal micro-controller or board power supply component failureInternal board failure — unit requires repair or replacement.

Frequently Asked Questions

What is the difference between the EVS9323-ESV004 and standard 9300 servo drives?

The V004 variant features cold-plate cooling technology, omitting internal cooling fins. It relies on direct thermal transfer to an external cooling surface or radiator, allowing for a significantly thinner housing profile inside the control cabinet.

Which software is used to configure the Lenze EVS9323-ESV004?

The controller is programmed and configured using Lenze Global Drive Control (GDC) software, or manually via the pluggable EMZ9371BC operating keypad.

What feedback encoder types are supported by this controller?

The unit natively supports resolvers via connector X7, as well as incremental and absolute encoders including TTL, SinCos, and Hiperface devices via connector X8.

How do I resolve a CE0 fault code on the EVS9323-ESV004?

A CE0 code indicates a CAN system bus fault. Check the CAN wiring for short circuits, ensure matching baud rates across all bus nodes, and verify that 120 Ohm termination resistors are present at both physical ends of the line.

Can I expand the drive to support PROFIBUS or EtherCAT fieldbus networks?

Yes. The controller contains a Slot A modular expansion bay that accepts fieldbus communication modules, including the EMF2133IB PROFIBUS module and EMF2192IB EtherCAT module.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.