Lenze EVS9324-ETV907 9300 Series Servo PLC Drive Controller

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze EVS9324-ETV907 is a 3.0 kW servo drive controller from the Lenze 9300 Series, specifically belonging to the 9300 Servo PLC family. Designed to integrate IEC 61131-3 compliant motion and logic control directly inside the drive housing, this compact IP20 unit operates on a 3-phase mains supply from 320 V AC to 528 V AC (400/480 V AC nominal). It delivers a continuous output current of 7.0 A and a peak output current capability of 10.5 A at an 8 kHz chopping switching frequency. The V907 hardware variant suffix designates a cold-plate mounting construction, which dissipates heat through a flat contact surface to an external heatsink or cabinet wall rather than relying on standard integrated fan fins.
Connecting and replacing an EVS9324-ETV907 requires careful attention to both software project alignment and physical interface options. The controller features onboard digital inputs and outputs (8 inputs, 4 outputs), analog channels (2 inputs, 2 outputs), a universal feedback interface supporting resolvers, TTL, SinCos, and Hiperface encoders, and an onboard CANopen system bus operating at speeds up to 500 kbps. Expansion into higher-level fieldbuses is handled via the Automation Interface (AIF) slot, which accepts plug-in communication modules such as the EMF2133IB PROFIBUS module or EMF2192IB EtherCAT module. Replacing a unit is not a simple plug-and-play process; technicians must transfer both drive parameters and the compiled IEC 61131-3 PLC application project using Lenze Global Drive Control (GDC) or Drive PLC Developer Studio (DDS), or via an EMF2102IB Keypad XT. When project files are inaccessible from a damaged drive, ABC Industrial Parts can assist in parameter extraction and configuration recovery from legacy memory structures.
For operational monitoring and troubleshooting, the drive housing provides direct visual diagnostics through three status LEDs: a solid green LED for power and ready state, a solid or flashing yellow LED for operating warnings such as current limits, and a solid or flashing red LED indicating a fault trip condition that disables drive outputs. Detailed diagnostic data, real-time CAN registers, and a stored fault history log are accessible through the GDC diagnostic window or DDS online monitoring. Common trip conditions include DC bus overvoltage (OU), motor overtemperature (OH4), and system bus errors (CE1), which can often be solved by inspecting network termination resistors or cooling setups. However, unrecoverable codes such as internal system failure (FAIL) or control board diagnostic failure (H05) signal non-field-serviceable hardware damage. In these cases, sourcing a fully tested exchange unit or utilizing rapid repair services from ABC Industrial Parts offers the most reliable pathway to minimize machinery downtime.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | EVS9324-ETV907 |
| Model / Type | EVS9324-ET V907 |
| Product Family | 9300 Series |
| Series | 9300 Servo PLC |
| Component Type | Servo Drive Controller |
| Rated Power | 3.0 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Continuous Output Current | 7.0 A |
| Maximum Output Current | 10.5 A |
| Power Loss | 110 W |
| Chopping Switching Frequency | 8 kHz |
| Ingress Protection Rating | IP20 |
| Cooling Construction | Cold-Plate Design (V907 Variant) |
| Digital I/O Channels | 8 Inputs / 4 Outputs |
| Analog I/O Channels | 2 Inputs / 2 Outputs |
| Integrated System Bus | CANopen (up to 500 kbps) |
Programming and Configuration
The Lenze EVS9324-ETV907 integrates full IEC 61131-3 programmable logic control into the drive electronics, allowing complex multi-axis motion and machine control logic to run directly on the drive unit. System setup and logic development are performed using Lenze Drive PLC Developer Studio (DDS), which supports standard programming languages including Ladder Diagram, Function Block Diagram, and Structured Text. Parameter adjustments and drive commissioning are managed separately or concurrently through Lenze Global Drive Control (GDC) software.
When commissioning a replacement controller, both the motion parameters and the active PLC runtime program must be loaded into the drive non-volatile memory. Parameter backup and download can also be executed directly at the machine using the optional EMF2102IB Keypad XT module. Ensuring that the PLC program version, communication settings, and motor feedback parameterization match the machine exact operational requirements is essential prior to enabling the drive stage.
Communication and System Integration
The EVS9324-ETV907 includes a built-in CANopen system bus interface operating at speeds up to 500 kbps. This integrated bus facilitates fast, deterministic multi-axis synchronization and electronic shaft or electronic cam functions between linked 9300 series drives without overburdening a central controller. Proper bus architecture requires 120-ohm termination resistors at both physical ends of the CAN network and correct node ID addressing.
To integrate with host control systems and higher-level automation networks, the drive features a dedicated Automation Interface (AIF) slot. This modular slot accommodates plug-in communication cards including the EMF2133IB for PROFIBUS-DP, EMF2192IB for EtherCAT, as well as modules for INTERBUS and LECOM RS232/RS485. During unit replacement, the AIF card from the original unit can be swapped into the replacement drive, provided address switches and fieldbus configurations are properly configured.
Diagnostics and Status Indication
Visual status feedback is provided on the front panel by three status LEDs. The green LED indicates power and ready status, glowing solid during normal active operation. The yellow LED illuminates or flashes during warning states, such as when current limits or thermal thresholds are reached. The red LED illuminates or flashes when a fault trip condition occurs, immediately disabling inverter output power to protect the drive and motor.
Advanced diagnostic feedback is accessed electronically via the EMF2102IB Keypad XT, the GDC diagnostic window, or DDS online status registers. Internal memory maintains a fault history log recording recent trip events. Network communications can also read CANopen system bus status registers and AIF communication states to pinpoint network interface drops or synchronization errors.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Green LED (Power/Ready) | Green - Solid | Drive active / controller ready for operation; normal operating state |
| Red LED (Fault) | Red - Solid/Flashing | Drive fault trip condition present; outputs disabled until fault is reset |
| Yellow LED (Warning) | Yellow - Solid/Flashing | Warning condition present (e.g., current limit reached, thermal warning) |
Replacement and Spare Part Considerations
When replacing an installed Lenze EVS9324-ETV907, verifying the physical cooling interface is critical. The V907 hardware variant features a cold-plate flat backplate designed to transfer heat directly to an external cooler or enclosure mounting surface. Replacing a V907 unit with a standard heatsink-and-fan model will result in thermal or mechanical mounting mismatches inside the control cabinet.
Before putting a spare drive into service, technicians must transfer both the operating parameters and the compiled IEC 61131-3 PLC program from the original unit or project archives using GDC or DDS. Additionally, any installed AIF expansion card (such as PROFIBUS or EtherCAT) must be transferred to the spare unit, verifying that node addresses, baud rates, and encoder feedback settings (whether resolver, TTL, SinCos, or Hiperface) match the existing installation.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OH | Heatsink Overtemperature | Heatsink temperature exceeds maximum allowable threshold (approx. 85°C) | Insufficient cooling airflow, ambient temperature too high, fan failure, or excessive drive load | Check cabinet ventilation, clean cooling fins, verify cabinet fan operation, and reduce motor load |
| OH4 | Motor Overtemperature | Motor thermal sensor (PTC / Klixon) triggered | Motor thermal overload, blocked motor shaft, or faulty thermal sensor wiring | Allow motor to cool down, inspect mechanical load for jamming, check motor thermistor connection at terminals |
| OC1 | Short Circuit / Earth Fault | Instantaneous overcurrent detection on inverter output | Short circuit in motor cable, motor winding ground fault, or damaged power stage module | Check motor cable insulation and phase-to-phase / phase-to-ground resistance. If fault occurs with motor disconnected, internal hardware fault requires unit repair/replacement. |
| OC2 | Overcurrent during Acceleration | Motor current limit exceeded during rapid acceleration ramp | Acceleration time too short, incorrect motor parameter configuration, or excessive mechanical inertia | Increase acceleration time ramp, adjust current limit settings, or check motor data auto-tuning |
| OU | DC Bus Overvoltage | DC bus voltage exceeded safe limit (> 770 V DC / 800 V DC) | Regenerative energy during deceleration too high, brake chopper resistor disconnected or defective, or mains supply voltage spikes | Increase deceleration time, check braking resistor connections and resistance value, measure mains supply voltage |
| LU | DC Bus Undervoltage | DC bus voltage dropped below minimum threshold (< 430 V DC) | Mains supply phase failure, low mains supply voltage, or blown input fuse | Check 3-phase incoming mains line supply and fuses, verify supply circuit breaker state |
| NMAX | Speed Limit Exceeded | Motor feedback speed exceeds maximum speed threshold | Speed loop instability, inverted feedback polarity, or runaway motor load | Check encoder/resolver wiring and shielding, verify speed loop gain settings and maximum speed parameter |
| CE0 | AIF Communication Fault | Communication failure between controller power unit and automation slot interface module | Loose or defective AIF communication module, bus cable break, or noise interference | Reseat AIF module in option slot, verify fieldbus cabling and termination resistors |
| CE1 | System Bus (CAN) Fault | CANopen / System bus communication error or node watchdog timeout | Broken CAN bus cable, missing 120-ohm termination resistor, incorrect node ID or baud rate mismatch | Verify CAN wiring, check bus termination resistors at both ends of network, verify baud rate settings |
| PR0 | PLC Task Overflow / Program Fault | IEC 61131-3 PLC runtime task execution exceeded configured cyclic task time | PLC program execution loop too long, infinite loop in code, or cycle time set too low | Optimize PLC program code in Drive PLC Developer Studio, or increase task cycle execution period |
| FAIL | System Failure | Internal micro-controller hardware fault or corrupt system memory | EEPROM corruption or severe internal hardware failure on control board | Internal hardware fault — power cycle drive unit. If fault persists, return unit for service or replace controller. |
| H05 | Internal Hardware Fault | Internal diagnostic check failed on control board | Control board hardware component failure | Internal hardware fault — non-field serviceable. Replace unit or contact Lenze service. |
Frequently Asked Questions
What does the V907 suffix in EVS9324-ETV907 mean?
The V907 suffix indicates the cold-plate mounting construction of the drive, where heat is dissipated through a flat back panel into an external heat sink or cabinet wall rather than using standard built-in heatsink cooling fins.
What software is required to program and configure the EVS9324-ETV907?
Drive parameterization and diagnostics are managed using Lenze Global Drive Control (GDC) software, while the integrated IEC 61131-3 PLC functionality is programmed using Lenze Drive PLC Developer Studio (DDS). Onsite parameter adjustments can also be made using the optional EMF2102IB Keypad XT.
Can I replace an EVS9324-ETV907 without re-uploading the PLC program?
No, because the unit contains an integrated IEC 61131-3 PLC, both the parameter set and the compiled PLC project software must be transferred to the replacement drive before it can execute machine control sequences.
Which communication protocols are supported on the EVS9324-ETV907?
The controller has an onboard CANopen system bus interface. It also features an Automation Interface (AIF) slot that supports option modules for PROFIBUS-DP (EMF2133IB), EtherCAT (EMF2192IB), INTERBUS, and LECOM RS232/RS485.
What does fault code OC1 indicate on the EVS9324-ETV907?
Fault code OC1 signals instantaneous overcurrent on the inverter output, typically caused by a short circuit in motor cabling, a ground fault in motor windings, or a damaged power output stage.
What should I do if the drive displays fault code FAIL or H05?
Fault codes FAIL and H05 indicate internal microcontroller hardware faults or corrupted internal memory on the control board. These conditions are non-field-serviceable; after attempting a power cycle, the unit should be returned for repair or replaced.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.