Product Family: 9300 Servo | Series: 9300 Series

The Lenze EVS9326-EK is an 11 kW servo controller engineered for complex, multi-axis motion applications requiring precise electronic cam profile execution. Belonging to the Lenze 9300 Servo family, this 9300 Servo Cam Profiler drive replaces mechanical cams with software-driven motion profiles, enabling rapid product changeovers and smooth acceleration curves in machinery such as flying shears, packaging lines, and printing presses. Constructed inside an IP20 enclosure, the unit operates from a three-phase mains input ranging from 320 V AC to 528 V AC at 45 to 65 Hz. It supplies a continuous output current of 23.5 A with a peak current capability of 35.3 A (150 percent rated current) for up to 60 seconds, driving AC servo motors across an output frequency range of 0 to 480 Hz at an 8 kHz switching frequency.

Interface options on the drive accommodate feedback signals and distributed control networks. Motor feedback connects via resolver input at connector X7 or multi-protocol encoder inputs (incremental, SinCos, EnDat, or SSI absolute encoders) at connector X8. Inter-drive synchronization is handled by an integrated CAN system bus on connector X4 operating at transmission speeds up to 500 kbit/s, while open option slot X1 accepts plug-in fieldbus adapters including PROFIBUS DP and CANopen. Commissioning a replacement unit involves transferring parameters and cam curve data stored in internal non-volatile EEPROM memory. A replacement module is rarely plug-and-run; parameter cloning and software transfer using Lenze Global Drive Control (GDC) software or the EMZ9371BC operating keypad are required to match the original drive's configuration. Technical support from ABC Industrial Parts can assist in preparing replacement drives and managing parameter migration.

Local status indication relies on built-in LEDs, including a solid green LED for operational ready status and a red LED indicating fault or trip conditions. Detailed diagnostics, error logs, and system bus registers are accessible using the EMZ9371BC keypad or through GDC software via diagnostic parameter C0009. Basic fault checks include inspecting mains power on terminals L1, L2, and L3, checking DC link voltage thresholds, evaluating feedback wiring at connectors X7 and X8, and verifying bus termination resistors on system bus X4. Internal microprocessor errors, memory corruptions, or gate-driver board faults cannot be serviced in the field; installing a fully tested exchange controller or using professional repair services through ABC Industrial Parts provides a direct solution for restoring machine operation.

Technical Specifications

ManufacturerLenze
Part NumberEVS9326-EK
Model / Type9300 Servo Cam Profiler
Component TypeServo Controller
Rated Power11 kW
Supply Voltage Range320 - 528 V AC
Supply Frequency45 - 65 Hz
Rated Output Current23.5 A
Maximum Output Current35.3 A (150% for 60 s)
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Integrated System BusCAN (500 kbit/s)
Protection RatingIP20

Programming and Configuration

The EVS9326-EK utilizes non-volatile internal EEPROM memory to store operation parameters, drive settings, and electronic cam profile tables. Motion profiles and operational parameters are configured using Lenze Global Drive Control (GDC) software or the plug-in EMZ9371BC control keypad. Using GDC, engineers can create custom interpolation tables, define motion profiles for cam indexing or flying shears, and adjust loop gains.

When commissioning or replacing a controller, complete parameter cloning can be performed via keypad copy functions or software backup restore. Restoring factory default settings is executed through parameter C0002. If a parameter mismatch or corrupted parameter set occurs on power-up (indicated by error code C0013), reloading the master configuration file or re-downloading the cam profile table via GDC clears the condition and restores valid drive execution.

Communication and System Integration

System integration relies on both built-in interfaces and optional fieldbus modules. An integrated CAN system bus at connector X4 provides real-time cross-axis communication at speeds up to 500 kbit/s. This system bus links master and slave axes for precise speed and position synchronization without requiring external controller hardware. Proper line termination using 120 Ohm resistors across the physical ends of the CAN bus is mandatory to prevent communication errors.

For higher-level PLC network integration, the drive features expansion slot X1. This slot accommodates communication cards including the EMF2131IB PROFIBUS DP module, EMF2175IB CANopen module, DeviceNet interfaces, or INTERBUS cards. Network parameters, node addresses, and fieldbus diagnostics are configured independently or managed via system registers monitored under parameter C0009.

Diagnostics and Status Indication

Visual status indication on the front panel provides instant operational feedback through two dedicated LEDs. The green 'Ready' LED signals drive status, illuminating solid when the control logic is active and ready for enable commands. The red 'Fault' LED illuminates solid or flashes during trip conditions, indicating active hardware or software errors.

Detailed troubleshooting is supported through the EMZ9371BC keypad, which displays plain-text error descriptions and specific fault codes. System diagnostic parameters, fault history logs, and realtime status registers are accessible through connected Global Drive Control (GDC) software or monitored via CAN system bus register C0009.

Status LED Indicators

LEDColor/StatusMeaning
ReadyGreen - SolidOperational state indicator: lit green when drive is ready for operation or enabled.
FaultRed - Solid or FlashingError indicator: blinking or solid red indicates active trip or fault state.

Replacement and Spare Part Considerations

When swapping a failed Lenze EVS9326-EK controller, ensure the exact model suffix matches. The '-EK' designation specifies the integrated 9300 Servo Cam Profiler software and hardware structure. Installing a standard 9300 servo positioning controller without cam profiler functionality will prevent electronic cam tables from executing.

Prior to placing the replacement drive online, transfer the exact parameter set and cam table data. Unplug the fieldbus communication card from slot X1 (such as an EMF2131IB PROFIBUS module) on the original unit and insert it into the replacement drive. Ensure the CAN system bus terminating resistors and node addresses on connector X4 match the system layout.

Verify that feedback devices connect to the appropriate physical terminals: resolver input on X7 or encoder signals on X8. If absolute encoders are used, check that encoder communication parameters and shield connections are preserved to avoid feedback errors (Sd1 through Sd6).

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
C0013Parameter set errorCorrupted parameter set or parameter error on power-upEEPROM write interrupted or bad parameter data loadedLoad factory default parameters (C0002) and reconfigure drive
CE0Communication error Slot X1Communication breakdown between controller and fieldbus module in Slot X1Loose fieldbus card, module fault, or bus cable interruptionCheck module seating in slot X1, verify fieldbus wiring, or replace fieldbus module
CE1CAN bus error (System Bus)Communication error on integrated CAN System Bus (X4)Bus wiring fault, missing terminating resistors (120 Ohm), or node address conflictCheck CAN lines at X4, verify baud rate and terminal resistor settings
EEREEPROM errorInternal EEPROM memory read/write access failureInternal hardware failure in memory chip or power interrupt during write operationInternal hardware fault — execute factory reset; if persistent, return unit for repair
H05Internal hardware errorInternal micro-controller hardware fault detected during self-testBoard-level failure in control logic circuitInternal hardware fault — not field serviceable, return unit for repair
H10Internal system faultSystem bus fault or severe internal software timing faultProcessor execution fault or hardware component failureInternal hardware fault — power cycle drive; if fault persists, replace unit
H11Internal communications errorFault in internal communication between control CPU and power sectionInternal ribbon cable or gate driver board faultInternal hardware fault — return unit for repair
LP1Mains phase failureOne phase missing on mains supply inputs L1, L2, L3Blown mains fuse, loose wire terminal, or unsymmetrical power gridCheck mains voltage at input terminals L1, L2, L3 and check line fuses
LUDC link undervoltageDC bus voltage dropped below lower voltage threshold (< 285 V DC)Mains supply interrupted, voltage dip, or charging resistor faultCheck input supply voltage and mains supply connections
NMAXSpeed threshold exceededMotor shaft speed exceeded maximum programmed thresholdIncorrect motor parameter setting, encoder slip, or unstable control loopCheck speed limit parameter C0596, feedback wiring, and speed controller tuning
OC1Short circuit / OvercurrentInstantaneous peak current limit exceeded on motor output terminals U, V, WShort circuit in motor winding or cable, acceleration time too short, motor undersizedCheck motor cable for short circuits or ground faults, inspect motor windings
OC2Earth faultGround fault detected on motor phases U, V, WInsulation breakdown in motor or motor cable to protective earth (PE)Measure insulation resistance of motor and cable with high voltage tester
OC5Overload during accelerationDrive current limit exceeded for an extended duration during accelerationMechanical blockage, excessive load inertia, or acceleration ramp too steepIncrease acceleration time or inspect mechanical drive line for jam
OHHeatsink overtemperatureDrive heat sink temperature exceeded maximum limit (> 90 °C)Fan failure, blocked cooling vents, excessive ambient temperature or continuous overloadClean heat sink cooling fins, check internal fan operation, verify cabinet ventilation
OH1Heatsink temperature monitoring tripHeatsink thermal switch triggeredHeat sink temperature above thresholdAllow drive to cool down and inspect cooling fan operation
OH3Motor thermal overload (PTC)Motor PTC / Klixon thermistor connected to X6/1 and X6/2 detected overtemperatureMotor thermal overload, insufficient motor cooling, broken thermistor cableAllow motor to cool down, check motor load, verify PTC sensor wiring
OH4Inverter thermal overload (I x t)Thermal overload threshold calculated by I x t inverter model reachedContinuous high motor current beyond continuous rating of 23.5 AReduce mechanical load or duty cycle on the drive controller
OUDC link overvoltageDC bus voltage exceeded safe maximum voltage (> 770 V DC / 800 V DC)Excessive regenerative energy during deceleration, missing or defective brake resistorIncrease deceleration ramp time, verify external brake resistor connection and value
PR0Cam profile program errorIllegal cam data structure or uninitialized cam profile tableIncomplete cam profile transfer or invalid cam interpolation dataRe-download valid cam table configuration using Global Drive Control (GDC)
PR1Cam synchronization faultLoss of synchronization between master axis and cam profile slave axisMaster encoder signal loss, excessive speed jump, or position pulse errorCheck master encoder wiring (X8/X9) and master frequency settings
Sd1Resolver faultResolver signal open circuit or phase feedback error on terminal X7Defective resolver wiring, damaged cable, or disconnected resolver connectorInspect resolver cable, check connector X7 seating and shield grounding
Sd2Encoder track errorIncremental encoder signal channel A, B, or Z fault at input X8Encoder cable wire break or missing encoder supply voltageCheck encoder wiring at X8, test encoder supply voltage
Sd3Encoder supply faultEncoder supply overload or short circuit detected at encoder socket X8Short circuit in encoder cable or excessive encoder current drainDisconnect X8 and measure encoder power lines for short circuit
Sd6Absolute encoder faultEnDat or SSI absolute encoder communication fault at connector X8Absolute encoder protocol failure, noisy feedback line, or bad cableCheck encoder cable shielding and absolute encoder configuration

Frequently Asked Questions

What software is used to program the Lenze EVS9326-EK?

The controller is programmed and configured using Lenze Global Drive Control (GDC) software. Parameter adjustments and cloning can also be performed via the plug-in EMZ9371BC operating keypad.

Can I replace an EVS9326-EK without re-entering parameters manually?

Yes, if a parameter backup exists in GDC software or if parameters are cloned directly using the EMZ9371BC keypad module from the original drive, the configuration and cam tables can be restored to the replacement unit.

How do I resolve a PR0 fault code on the drive?

A PR0 fault indicates an illegal cam data structure or uninitialized cam profile table. Re-downloading the verified cam table configuration via Lenze Global Drive Control (GDC) resolves this condition.

What feedback types are supported by the EVS9326-EK?

The drive supports resolver feedback connected at terminal X7, as well as incremental encoders, SinCos encoders, and absolute encoders (EnDat or SSI protocols) connected at connector X8.

What does error code H05 or H11 indicate?

Error codes H05, H10, and H11 indicate internal micro-controller or internal communication hardware faults. These errors are not field-serviceable and require returning the unit for repair or replacing the controller.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.