Lenze EVS9329-EK 9300 Series 30 kW Servo Cam Profiler

New 
On request
Refurbished   
5 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300

The Lenze EVS9329-EK is a 30 kW panel-mounted servo controller from the 9300 Servo series, engineered specifically as a Servo Cam Profiler for dynamic motion control applications. Designed for installation inside an IP20 control cabinet, the drive operates from a 3-phase supply voltage ranging from 320 V AC to 528 V AC. It provides a rated continuous output current of 59 A with a peak current rating of 88.5 A for dynamic acceleration phases up to 60 seconds. The -EK function variant features integrated electronic cam profiling firmware (Kurvenscheibe), enabling direct execution of motion profiles and electronic cam tables without external motion control computing overhead.

System connectivity includes a primary resolver input at terminal X7, a master frequency incremental encoder input at X8, and a master frequency simulator output at X9 to enable multi-axis line synchronization. Inter-drive communication is managed via an integrated CAN system bus interface at connector X14 running at up to 500 kbit/s, while an integrated Slot A receptacle supports optional fieldbus modules such as PROFIBUS-DP (EMF2133IB), INTERBUS (EMF2102IBC), or LECOM RS-232/RS-485 interfaces. Commissioning a spare unit requires transferring the drive parameter set and electronic cam profiles stored in the non-volatile EEPROM using Global Drive Control (GDC) software or a pluggable Keypad XT operator panel (EMF2171IB). Support for parameter transfer and option module verification is available through ABC Industrial Parts.

Real-time operational monitoring is provided by three diagnostic status LEDs on the front panel: green indicates normal operation and readiness, yellow signals a warning, current limit, or controller inhibit, and red alerts to an active TRIP fault state. Detailed diagnostic codes can be retrieved via parameter C0168 using the Keypad XT, through CAN system bus status registers, or via the digital TRIP output terminal. While line faults such as short circuits (OC1), earth leakage (OC2), or DC bus overvoltage (OU) can often be resolved by checking field wiring and mains supply lines, internal errors such as EEPROM read/write failures (EER) or power section hardware defects (H05, H07, H10, H11) cannot be serviced on site and require unit replacement or repair through ABC Industrial Parts.

Technical Specifications

ManufacturerLenze
Part NumberEVS9329-EK
Model / Type9300 Servo Cam Profiler
Component TypeServo Controller
Rated Power Output30 kW
Supply Voltage Range320 - 528 V AC
Supply Phase3-Phase
Continuous Output Current59 A
Peak Output Current88.5 A
Maximum Output Frequency480 Hz
Switching Frequency8 kHz
Integrated System BusCAN Bus (500 kbit/s)
Protection RatingIP20
Mounting TypePanel Mount

Programming and Configuration

The Lenze EVS9329-EK contains non-volatile EEPROM memory capable of holding up to four complete parameter sets along with specialized electronic cam tables. Setting up motion profiles and operational thresholds is performed using Lenze Global Drive Control (GDC) engineering software connected via a suitable diagnostic interface, or directly at the drive using an optional Keypad XT (EMF2171IB) module.

Because the -EK variant executes electronic cam profiles internally, configuration files control motor parameters, acceleration curves, speed loop tuning, switching frequency (rated at 8 kHz), and master-slave axis coordination. When commissioning a replacement unit, backing up the parameter file from the original unit or loading a stored GDC project file ensures that exact cam profile data and axis control setpoints are restored accurately.

Communication and System Integration

System integration across multi-axis machinery is achieved through integrated interfaces and optional communication modules. The drive features a built-in CAN system bus interface accessible at connector X14, running at speeds up to 500 kbit/s to synchronize multiple drives across a common bus network.

In addition to the onboard CAN bus, the unit includes modular Slot A for expanding communication capability. Option modules compatible with Slot A include PROFIBUS-DP (EMF2133IB), INTERBUS (EMF2102IBC), and LECOM RS-232/RS-485 modules. Physical axis synchronization is supported through the master frequency encoder input (X8) and simulator output (X9), along with standard resolver feedback at connector X7.

Diagnostics and Status Indication

The Lenze EVS9329-EK provides status feedback through hardware indicators, diagnostic parameters, and output terminals. Three front panel status LEDs give immediate visual feedback on the current operating state, distinguishing between normal operational readiness, active limit warnings, and fault conditions.

Detailed fault analysis can be conducted by connecting the Keypad XT module to view diagnostic parameter C0168. Status and error bits are also transmitted across the CAN system bus registers, and a hardware TRIP output terminal is provided on the control terminal strip for automated PLC fault signaling.

Status LED Indicators

LEDColor/StatusMeaning
Red LEDRed - Solid/ActiveTRIP active / Fault state present in controller
Green LEDGreen - Solid/ActiveController ready / normal operation active
Yellow LEDYellow - Solid/ActiveWarning state / current limit reached / controller inhibit active

Replacement and Spare Part Considerations

When replacing an existing unit, confirm that the replacement model matches the exact EVS9329-EK designation. Standard 9300 series drives lack the internal electronic cam profiling firmware supplied with the -EK variant, which is necessary to execute onboard motion profile tables.

Prior to putting a spare drive into service, transfer all stored parameter sets and cam profile data from the original unit using GDC software or a Keypad XT module with its removable memory card. Additionally, remove any option module fitted in Slot A (such as PROFIBUS-DP EMF2133IB or INTERBUS EMF2102IBC) from the original drive and re-install it into the replacement unit.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit at motor terminals or in motor cableShort circuit in motor windings or cabling, low inductance motorCheck motor cable and terminal block for short circuit, test motor insulation
OC2Earth FaultEarth/ground fault on motor output linesGround connection in motor cable, motor winding isolation breakdown, excessive cable capacitanceCheck cable and motor windings for earth leakage using megohmmeter, reduce motor cable length
OC5Overcurrent AccelerationOvercurrent during dynamic acceleration phaseAcceleration time too short, mechanical blockage, incorrect motor parametersIncrease acceleration time, check mechanics for binding, verify motor control parameters
OUOvervoltage DC BusDC bus circuit voltage exceeded upper threshold limitDeceleration ramp too short, regenerative energy feedback, line overvoltage, brake chopper failureExtend deceleration time, connect dynamic braking resistor, check mains supply voltage
LUUndervoltage DC BusDC bus circuit voltage dropped below minimum threshold limitMains supply line failure, missing input phase, mains supply drop under loadCheck mains power supply lines, input fuses, and line reactor
OHOvertemperature HeatsinkDrive heat sink temperature exceeded maximum allowed limitInadequate control cabinet ventilation, dirty or blocked heatsink fins, fan failureClean heatsink, ensure enclosure fan is operational, improve cabinet cooling
OH3Overtemperature Motor SensorMotor temperature sensor trip via control terminals X10Motor thermal overload, continuous excessive load, defective thermal switch/PTCAllow motor to cool down, check mechanical load, verify motor PTC connection
OH4Overtemperature Drive InteriorInternal ambient temperature inside drive housing too highExcessive enclosure temperature, cooling airflow restrictedReduce ambient panel temperature, check control cabinet airflow
OH7Motor Thermal Overload (I2t)Calculated motor load I2t monitor limit reachedContinuous operation above rated motor current, improper motor current setpointReduce continuous motor duty cycle, check motor dimensioning and current parameters
CE0Communication Fault Slot ACommunication failure with option module inserted in automation slot AFieldbus interruption, loose module connection, master PLC watchdog tripCheck fieldbus cabling, bus termination resistors, and module mounting
CE1System Bus CAN FaultCommunication error on integrated CAN system bus X14CAN bus wire broken, missing 120 ohm termination, baud rate mismatchCheck CAN bus wiring, ensure 120 ohm resistors at both end nodes, verify baud rate
CE2System Bus CAN Rx OverflowReceive buffer overflow on CAN system busExcessive bus load, message transmission rate too highOptimize CAN bus message timing, reduce cyclic transmission rate
CE3System Bus CAN Tx OverflowTransmit buffer overflow on CAN system busCAN bus in error passive state, no acknowledge from bus partnersVerify CAN nodes connected, check cable continuity
PR0Parameter Set ErrorChecksum error or invalid data detected during parameter set loadingInterrupted transfer, corrupted memory fileReload parameter set from GDC or reload factory defaults
PR1Parameter Module ErrorMissing or improperly inserted pluggable memory moduleMemory module absent or bad electrical contactCheck memory module insertion, power off and re-seat module
EEREEPROM Read/Write ErrorInternal EEPROM memory read or write access failedEEPROM memory hardware faultInternal hardware fault — return unit for repair or replace servo controller
H05Power Section Hardware ErrorInternal error detected in power stage feedback / gate drive hardwareDefective internal power module or current sensor boardInternal hardware fault — return unit for repair
H07Internal Voltage FaultInternal auxiliary supply power failure inside drive electronicsDefective internal switch-mode power supply boardInternal hardware fault — return unit for repair
H10Internal Controller ErrorMain processor internal control logic failureDefective control board micro-controller unitInternal hardware fault — return unit for repair
H11System Software Hardware FaultFatal internal hardware/firmware execution errorControl board malfunctionInternal hardware fault — return unit for repair
P12Mains Phase FailureMissing phase on incoming 3-phase mains supplyBlown mains fuse, loose incoming line connection, unstable supply gridCheck three mains input phases under load conditions
NMAXMaximum Speed ExceededMotor speed exceeded configured nmax safety limitUnstable speed loop tuning, incorrect encoder pulse count, runaway conditionCheck speed controller parameters, encoder feedback resolution, and nmax threshold

Frequently Asked Questions

What does the -EK variant code indicate on the Lenze EVS9329-EK?

The -EK suffix indicates that the controller includes integrated electronic cam profiling firmware (Kurvenscheibe), enabling it to execute complex dynamic motion profiles and electronic cam tables locally without external PLC motion controllers.

What software and operator panels are used to program the EVS9329-EK?

Drive parameters and electronic cam tables are configured using Lenze Global Drive Control (GDC) software or locally using the pluggable Keypad XT (EMF2171IB) operator panel.

Which fieldbus options are supported by the EVS9329-EK?

The drive includes an onboard CAN system bus interface (X14) operating at 500 kbit/s. Optional fieldbus modules for Slot A include PROFIBUS-DP (EMF2133IB), INTERBUS (EMF2102IBC), and LECOM RS-232/RS-485 interfaces.

What steps are required when replacing a faulty EVS9329-EK drive?

Ensure the replacement drive is an exact -EK variant, transfer the stored parameter sets and electronic cam tables using GDC software or Keypad XT memory, and move any option card from Slot A to the replacement unit.

What do internal fault codes like EER, H05, or H10 mean?

Codes such as EER (EEPROM fault), H05 (power stage error), H07 (internal power supply fault), H10 (controller error), and H11 (hardware/software execution error) indicate internal hardware failures that require returning the unit for repair or exchanging it for a tested spare.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.