Lenze EVS9329-EPV004 9300 Servo Position Controller 30 kW

New 
On request
Refurbished   
5 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300

The Lenze EVS9329-EPV004 is a 30 kW servo position controller from the 9300 Servo drive series. Designed for precision multi-axis positioning and synchronized motion control, this IP20-rated controller operates on a 3-phase AC line voltage ranging from 320 V to 528 V at 50/60 Hz. The drive delivers a continuous rated output current of 59 A and supports a maximum overload current of 88.5 A for up to 60 seconds, providing necessary dynamic performance for demanding industrial machinery. Featuring specialized positioning software integrated into the drive firmware, the EP variant generates motion profiles directly, making it suitable for packaging machinery, rotary indexing tables, and material handling axes.

Connecting and commissioning a replacement EVS9329-EPV004 requires establishing physical interfaces and matching software configurations. Motor feedback is handled via a Sub-D resolver input alongside master frequency encoder input and output connections operating at frequencies up to 500 kHz. Network integration is available through an integrated CANopen system bus running at up to 500 kbit/s, while an automation slot accepts option cards such as the EMF2133IB PROFIBUS, EMF2173IB DeviceNet, or EMF2102IB INTERBUS communication modules. Putting a replacement drive into service requires restoring parameter sets stored across four internal EEPROM memories using either the EMZ9371BC XT keypad module or Lenze Global Drive Control (GDC) software, a task where ABC Industrial Parts can support parameter backup and device setup.

Diagnostics and status indication are provided through onboard LED indicators and software monitoring tools. Operational status is indicated by a solid green LED for ready states and a solid red LED for TRIP fault conditions requiring reset. Diagnostic parameters, including the TRIP history log stored in parameter C0168, can be checked via GDC software or the keypad display. Standard troubleshooting steps include checking supply lines, power connections, encoder feedback, and motor thermal sensors. If an unserviceable control board error such as fault code H05 persists after cycling power, replacing the unit or sending it for repair through ABC Industrial Parts provides a rapid path back to full production.

Technical Specifications

Rated Power30 kW
Supply Voltage Range320 - 528 V AC
Rated Output Current59 A
Maximum Output Current88.5 A
Carrier Switching Frequency8 kHz
Output Frequency Range0 - 480 Hz
IP Protection RatingIP20

Programming and Configuration

Configuration of the Lenze EVS9329-EPV004 is executed using Lenze Global Drive Control (GDC) software or the optional EMZ9371BC operating module (XT Keypad). GDC software enables real-time parameter configuration, positioning profile creation, and drive diagnostics over a PC connection.

The drive contains four internal switchable EEPROM parameter sets. These non-volatile memory areas store motor control settings, limit thresholds, and motion profiles. During replacement, saved parameter sets can be uploaded from the original unit and downloaded into the spare controller, avoiding manual reprogramming of positioning steps.

Communication and System Integration

The EVS9329-EPV004 features an integrated CANopen System Bus interface supporting data transfer rates up to 500 kbit/s. This bus allows high-speed communication between multiple 9300 series drives and higher-level automation controllers for synchronized multi-axis operations.

Additional fieldbus flexibility is provided through an integrated modular automation slot. Depending on network requirements, optional communication modules can be installed, including the EMF2133IB for PROFIBUS-DP, the EMF2173IB for DeviceNet, and the EMF2102IB for INTERBUS networks.

Diagnostics and Status Indication

Operational monitoring is facilitated via onboard LED indicators and parameter readouts. Operating states and fault messages can be evaluated through status words over fieldbus networks, the EMZ9371BC keypad display, or the GDC diagnostic monitor.

Detailed fault tracking is accessible via parameter C0168, which retains a log of recent TRIP events to assist in identifying recurrent electrical or mechanical issues.

Status LED Indicators

LEDColor/StatusMeaning
Green LED (Ready)Green - SolidOperational status / Drive enabled and ready for operation when continuously lit.
Red LED (TRIP / Fault)Red - SolidFault indication / Drive tripped due to active fault or internal error requiring acknowledgment.

Replacement and Spare Part Considerations

When swapping out a failed Lenze EVS9329-EPV004, ensure the replacement unit shares the exact model designation to match power ratings and integrated positioning firmware capabilities. Transfer any existing fieldbus communication modules from the original drive's automation slot to the replacement unit.

Because parameters are stored locally within internal EEPROM memory, a replacement drive will not operate correctly until the specific machine parameters are loaded. Use Global Drive Control software or the EMZ9371BC keypad module to transfer saved parameter sets to complete the installation.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / OvercurrentShort circuit or extreme overcurrent in the motor circuit during acceleration.Short circuit in motor winding or motor cable; ground fault; acceleration time too short.Check motor and wiring for short circuit or ground fault; check acceleration ramp times.
OC2Overcurrent during DecelerationExcessive current during motor deceleration phase.Deceleration time set too short; braking resistor not connected or defective.Extend deceleration time; check brake chopper / braking resistor circuit.
OC5I x t OverloadContinuous overload condition (I x t limit reached).Drive undersized for mechanical load; mechanical blockage; continuous load too high.Check machine mechanics for binding or overload; verify drive sizing.
OUOvervoltage DC BusDC bus link voltage exceeded upper threshold.Regenerative energy from deceleration too high; braking resistor missing, defective, or misdimensioned; mains voltage too high.Check brake module and braking resistor; extend deceleration time; check mains supply voltage.
LUUndervoltage DC BusDC bus voltage dropped below minimum operating limit.Mains supply voltage failure or phase missing; power supply interruption.Check line supply voltage and fuses; check main contactor circuit.
OHHeatsink OvertemperatureController heatsink temperature exceeded maximum allowable limit.Insufficient cabinet cooling/ventilation; ambient temperature too high; dirty heatsink/fan fault.Clean heatsink, ensure proper air flow in enclosure, check fan operation and ambient temperature.
OH4Motor OvertemperatureMotor thermal sensor detected overtemperature condition.Motor overload; motor cooling fan failure; incorrect thermal sensor parameter setting.Allow motor to cool; check motor load and forced-cooling fan; verify PTC/KTY connection on terminal X10.
CE0Automation Slot Communication FaultCommunication failure between control board and installed fieldbus module.Communication module improperly seated, defective, or fieldbus cable disconnected.Check module seat in Automation Slot; check external fieldbus wiring and bus master status.
CE1CAN Bus Communication FaultError condition or timeout on integrated System Bus (CAN).CAN bus line break, missing bus termination resistors, or high noise interference.Check CAN wiring, shield grounding, baud rate settings, and 120-ohm termination resistors.
H05Internal Hardware FaultControl board internal hardware evaluation failed.Internal electronic components damaged or control board hardware revision conflict.Internal hardware fault — power cycle unit; if persistent, return unit for factory repair or replacement.
NMAXSpeed Limit ExceededActual motor speed exceeded configured maximum speed limit.Speed loop tuning overshoot; motor runaway; feedback device slipping/defective.Check feedback encoder/resolver connections and speed controller gain settings.
LPPhase FailureOne phase of the 3-phase mains supply is missing.Blown input fuse, loose power wiring connection, or phase imbalance.Check 3-phase line supply voltage and input protective devices.
PRPositioning ErrorPositioning tracking error tolerance exceeded or software limit switch reached.Excessive mechanical drag, incorrect acceleration/velocity profiles, software limit setting mismatch.Check positioning parameters, mechanical drive assembly, and position error limit threshold.
SDResolver / Encoder FaultFeedback signal error detected on X7 resolver or X8 encoder interface.Broken encoder/resolver cable, improper shielding, defective feedback transducer.Inspect feedback cable connection, check for signal wire breakage, test resolver/encoder.

Frequently Asked Questions

How are parameters transferred to a replacement Lenze EVS9329-EPV004 drive?

Parameters can be uploaded from the original drive and restored to the replacement unit using Lenze Global Drive Control (GDC) software or an EMZ9371BC XT keypad module connected directly to the drive.

What fieldbus protocols are supported by the EVS9329-EPV004?

The drive includes an integrated CANopen system bus up to 500 kbit/s. PROFIBUS-DP, DeviceNet, or INTERBUS communication can be added using dedicated option modules inserted into the automation slot.

What does a solid red LED indicate on the front panel?

A solid red LED indicates a TRIP fault status, signaling that the drive has shut down due to an active fault or internal condition that must be cleared and acknowledged.

What action should be taken if fault code H05 appears?

Fault code H05 indicates an internal control board hardware fault. Power cycle the drive; if the fault persists, internal electronics are damaged and the unit must be repaired or replaced.

What feedback interfaces are available on this positioning controller?

The unit features a Sub-D resolver input interface (X7) and master frequency encoder input/output connections (X8) supporting operating frequencies up to 500 kHz.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.