Lenze EVS9330-ESV004 9300 Series 45kW Servo Inverter

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 | Series: 9300 Servo Inverters

The Lenze EVS9330-ESV004 is a panel-mounted 45 kW servo inverter from the Lenze 9300 series (model designation EVS9330-ES), engineered to deliver field-oriented vector control for both synchronous and asynchronous AC servo motors. Providing a continuous output current of 89 A at a 4 kHz switching frequency within an IP20 enclosure, this unit enables precise torque management and velocity control in multi-axis industrial motion applications. The V004 configuration designates an integrated Safe Stop hardware safety function, allowing safe power disconnection without requiring external safety contactors.

Operating on a three-phase supply range of 320 V AC to 528 V AC (45 to 65 Hz), the drive features standard physical connections including a SUB-D interface for resolver feedback on input X8, master frequency input and output connections, and an integrated CAN System Bus supporting CANopen protocols. System expansion is managed via Automation Slot A, which supports option modules for PROFIBUS-DP (EMF2133IB/EMF2131IB), DeviceNet (EMF2177IB/EMF2174IB), and INTERBUS (EMF2113IB/EMF2111IB). Commissioning a replacement unit requires restoring the machine's parameter profile, which can be loaded from non-volatile EEPROM storage using the optional XT Keypad (EMF2102IB) or via Lenze Global Drive Control (GDC) software. Preparing a replacement unit through ABC Industrial Parts ensures proper parameter alignment and interface verification prior to installation.

Front-panel status indication is provided by three color LEDs showing operational readiness, active pulse inhibit/current limit, and fault status. The internal controller stores the four most recent TRIP events in a dedicated fault history memory buffer, accessible through the XT Keypad, GDC software, or CANbus registers. External faults caused by supply disturbances or feedback disconnects can be resolved through external checks, but internal errors such as hardware failures or memory corruption require hardware-level repair or complete drive replacement. When internal board faults bring production to a halt, sourcing a fully tested exchange unit or repair option through ABC Industrial Parts provides a direct route back to operation.

Technical Specifications

ManufacturerLenze
Part NumberEVS9330-ESV004
Model / TypeEVS9330-ES
Product Family9300
Component TypeServo Drive
Rated Power45 kW
Rated Continuous Current89 A
Supply Voltage Range320 V AC to 528 V AC
Mains Frequency Range45 Hz to 65 Hz
Switching Frequency4 kHz
Protection RatingIP20
Mounting StylePanel Mount
Integrated Safety FunctionSafe Stop (V004 Variant)

Programming and Configuration

Configuration and parameter setup for the Lenze EVS9330-ESV004 are executed using Lenze Global Drive Control (GDC) software or directly via the pluggable XT Keypad (EMF2102IB) connected to Keypad Slot X6. The drive contains non-volatile EEPROM memory capable of retaining up to four independent parameter sets, allowing versatile control scheme switching or straightforward backup creation.

When commissioning a replacement drive, parameters can be cloned directly from the internal EEPROM of a configured unit using the XT Keypad without requiring a PC connection. Alternatively, parameter sets can be uploaded and downloaded over the system bus using GDC software connected via a PC system bus adapter.

Communication and System Integration

The EVS9330-ESV004 features a built-in CAN System Bus interface supporting CANopen protocols for real-time motion control coordination and parameter exchange across multi-axis networks. In addition to system bus communication, the drive offers master frequency input and output interfaces for drive synchronization and position feedback.

Fieldbus connectivity is achieved through modular option cards installed in Automation Slot A. Compatible communication modules include PROFIBUS-DP (EMF2133IB / EMF2131IB), DeviceNet (EMF2177IB / EMF2174IB), and INTERBUS (EMF2113IB / EMF2111IB). When replacing a unit, the installed fieldbus module can be unclipped and transferred directly to the spare drive.

Diagnostics and Status Indication

The front panel of the EVS9330-ESV004 includes three status LEDs that provide visual operational diagnostics. The drive also logs diagnostic parameters across CANbus registers and maintains a fault history memory buffer storing details of the last four TRIP events.

Detailed parameter inspection and fault log analysis can be conducted on-site using the LCD display of the XT Keypad (EMF2102IB) or remotely via Global Drive Control (GDC) software over the system bus interface.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP)Red - SolidInverter fault / TRIP state active; output stage disabled.
Green LED (Ready)Green - Blinking / SolidInverter power stage ready for operation (blinking = standby, solid = enabled/operating).
Yellow LED (IMP / Current limit)Yellow - Solid / FlashingPulse inhibit active or motor current limit reached.

Replacement and Spare Part Considerations

When selecting a replacement unit for the EVS9330-ESV004, ensure the part number matches the V004 suffix, which indicates integrated Safe Stop hardware capability. Installing a standard variant without Safe Stop will cause safety circuit incompatibilities and prevent machine operation.

Before placing a replacement unit into service, transfer any option modules installed in Automation Slot A (such as PROFIBUS or DeviceNet cards) and restore the original parameter set using an XT Keypad or Global Drive Control software. For new machine designs or long-term plant modernization, the Lenze i950 cabinet servo drive series is recommended as a modern replacement path.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / OvercurrentInstantaneous overcurrent in inverter power output stage.Short circuit in motor windings or motor cable; acceleration time too short; motor insulation failure.Check motor and motor cable for phase-to-phase or phase-to-ground short circuit; increase acceleration ramp times.
OC2Earth FaultGround fault / earth current detected on inverter output.Earth fault in motor lead or motor winding.Check motor wiring and motor insulation resistance to earth.
OC5I x t OverloadContinuous overload threshold reached (inverter thermal load limit exceeded).Inverter operated under continuous overload conditions beyond rated continuous output current.Check drive sizing against load profile; reduce continuous motor current demand.
OUDC Bus OvervoltageDC bus link voltage exceeded upper safety threshold (>770 V DC).Excessive braking energy regenerated into DC bus; braking resistor defective or disconnected; deceleration ramp too steep.Increase deceleration ramp time; check braking resistor connection and chopper resistor function.
LUDC Bus UndervoltageDC bus link voltage dropped below minimum operating limit.Mains supply power outage, missing input phase, or low input line voltage.Check mains voltage, input line fuses, and line reactor.
OHHeatsink OvertemperatureDrive heatsink temperature exceeded maximum allowed limit.Dirty or clogged heatsink; broken internal cooling fan; ambient cabinet temperature too high.Clean heatsink cooling fins; verify operation of heatsink fan; improve cabinet ventilation.
OH4Motor Overtemperature (PTC)Motor thermal contact / PTC sensor tripped.Motor overheated due to overload or lack of external motor cooling.Allow motor to cool down; check motor load and forced ventilation fan if present.
Sd2Resolver FaultLoss or corruption of resolver feedback signal on input X8.Resolver cable disconnected, broken wire, bad shielding, or defective resolver.Inspect resolver cable, shielding connection, and connector X8 pin continuity.
CE0System Bus Communication ErrorCommunication failure on CAN system bus.Interrupted bus connection, missing 120-ohm termination resistors, or baud rate conflict.Check CANbus wiring, shield grounding, termination resistors, and node configuration.
H05Internal Hardware FailureInternal hardware or control board failure.Internal circuit defect or component damage.Internal hardware fault — power cycle drive; if persistent, return unit for repair.
EEREEPROM Memory ErrorCorrupted non-volatile parameter memory.EEPROM write error or internal memory fault.Reset parameters to factory default settings; if error persists, internal control board repair is required.

Frequently Asked Questions

What is the significance of the V004 designation on the Lenze EVS9330-ESV004?

The V004 designation indicates that the servo drive is equipped with an integrated Safe Stop safety function. This integrated hardware safety feature allows safe power disconnection according to safety standards without requiring external safety contactors.

How are parameters transferred to a replacement EVS9330-ESV004 drive?

Parameters can be transferred by cloning parameter sets stored in the internal EEPROM using the optional XT Keypad (EMF2102IB) directly at the drive, or by uploading and downloading configuration files via Lenze Global Drive Control (GDC) software over the system bus adapter.

Which fieldbus communication options are supported by this servo drive?

In addition to its built-in CAN System Bus (CANopen), the EVS9330-ESV004 supports fieldbus expansion modules via Automation Slot A. Compatible modules include PROFIBUS-DP (EMF2133IB/EMF2131IB), DeviceNet (EMF2177IB/EMF2174IB), and INTERBUS (EMF2113IB/EMF2111IB).

What does a solid red TRIP LED indicate on the front panel?

A solid red TRIP LED indicates an active inverter fault condition. When active, the inverter output stage is disabled. The fault cause can be identified using the XT Keypad, GDC software, or reading diagnostic registers over the system bus.

What action should be taken if the drive displays an H05 fault code?

An H05 fault code indicates an internal hardware failure on the control board or internal circuitry. First perform a complete power cycle; if the fault persists upon rebooting, the drive requires hardware repair or replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.