Lenze 387069 EZN3A0900H004 3-Phase Mains Choke
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 387069, designated by model code EZN3A0900H004, is a 3-phase mains choke from the EZN series engineered for power conditioning on industrial variable frequency drive AC supply lines. Featuring a rated inductance of 9.0 mH and a continuous current capacity of 4.0 A, this line reactor functions as an inductive filter positioned between the incoming power grid and downstream drive electronics. Operating on 3-phase supply networks up to 480 V AC, the component is frequently deployed alongside Lenze 8200 Vector series inverters to smooth input current waveforms, mitigate grid harmonic distortion, and protect drive power stages from transient voltage spikes.
Integrating the EZN3A0900H004 line reactor into a machine enclosure involves straightforward 3-phase power wiring between the AC supply mains and the inverter input terminals. As a passive inductive component, the reactor requires no software parameterization, firmware setup, or rotary switch configuration prior to operation. When replacing a damaged unit, commissioning requires securing the IP00 module within a protective control panel, ensuring correct terminal connection torque, and confirming phase alignment. Maintenance teams can rely on ABC Industrial Parts for acquiring ready-to-install replacement units to minimize operational downtime.
As a purely passive power accessory, the EZN3A0900H004 contains no active electronic diagnostics, LED status indicators, or fault code displays. Operational checks focus on verifying input phase symmetry, inspecting physical terminal connections for thermal tightness, and checking winding insulation integrity following major grid disturbances. Internal electrical breakdown or physical winding failure caused by severe line surges cannot be serviced in the field and requires a direct unit swap. Sourcing a tested replacement through ABC Industrial Parts ensures rapid restoration of system power filtering and long-term inverter protection.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 387069 |
| Model / Type | EZN3A0900H004 |
| Product Family | EZN Series |
| Component Type | 3-Phase Mains Choke |
| Inductance | 9.0 mH |
| Rated Current | 4.0 A |
| Maximum Supply Voltage | 480 V AC |
| Number of Phases | 3 |
| Protection Rating | IP00 |
Replacement and Spare Part Considerations
When selecting a replacement for a Lenze 387069 line reactor, technicians must ensure that the continuous current rating of 4.0 A and inductance rating of 9.0 mH match the precise power specification of the installed frequency inverter. Installing a choke with incorrect inductance or current ratings can result in excessive drive bus voltage drop, increased thermal dissipation, or reduced attenuation of line harmonics.
Because the EZN3A0900H004 contains no memory modules, digital software, or stored parameter sets, replacing a failed reactor is entirely a physical and electrical hardware operation. The replacement unit can be mounted directly into the cabinet slot, taking care to observe the IP00 open-construction safety requirements and verifying that enclosure cooling airflow is unobstructed.
Frequently Asked Questions
What is the primary function of the Lenze 387069 line reactor?
The Lenze 387069 (EZN3A0900H004) is a 3-phase mains choke that filters mains voltage surges, dampens input current harmonics, and protects variable frequency drive power stages from grid transients.
Does the EZN3A0900H004 require software configuration before use?
No, the EZN3A0900H004 is a passive power component and requires no software programming, parameter transfer, or digital setup.
Which drive systems are compatible with this mains choke?
This line reactor is designed for 3-phase 400 V / 480 V AC drive installations requiring a 4.0 A / 9.0 mH reactor, including Lenze 8200 Vector series inverters.
What protection rating does the Lenze 387069 feature?
The unit carries an IP00 protection rating, requiring installation inside a protective control cabinet to shield against direct contact and environmental contamination.
How are faults diagnosed on the EZN3A0900H004 reactor?
As a passive component without LEDs or electronic diagnostics, troubleshooting involves checking phase voltages, terminal connections, and inspecting for physical overheating or winding insulation failure.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.