Lenze E82EV552_2C 8200 Vector Frequency Inverter 5.5kW / 7.5HP 230V

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze E82EV552_2C is a panel-mounted frequency inverter from the 8200 Vector series, engineered to provide dynamic speed and torque control for 3-phase AC asynchronous motors. Operating from a 3-phase 230V AC input across a permissible voltage range of 180V to 264V AC, this AC drive provides a rated power output of 5.5 kW (7.5 HP) with a continuous output current of 24A. It supports linear V/f, quadratic V/f, sensorless vector control, and torque control modes, making it suitable for applications such as conveyor systems, industrial pumps, ventilation fans, material handling equipment, and machine tools.
Designed with a modular hardware configuration, the drive consists of a base power section and an interchangeable plug-in function slot. This setup accepts function and fieldbus communication modules including CANopen, PROFIBUS-DP, DeviceNet, INTERBUS, and Modbus RTU or LECOM. Commissioning and parameter cloning are managed using either the plug-in Lenze E82ZBC XT Keypad Module or Lenze Global Drive Control (GDC) PC software. The internal non-volatile EEPROM stores up to four independent parameter sets to facilitate rapid parameter duplication across identical units. When replacing an existing unit, ABC Industrial Parts can assist with parameter backup extraction and configuration support to streamline restoring system operation.
Comprehensive diagnostic capability is provided via dual-color red and green status LEDs located on the front panel and module faces, signaling operational readiness, pulse inhibit, and active fault states. Detailed troubleshooting is performed by reading parameters C0161 for active TRIP faults and C0168 for historical TRIP events using the keypad module or GDC software. Common maintenance checks include verifying mains phase balance, evaluating input line supply voltages, and testing output wiring integrity across phases U, V, and W. In cases where internal hardware failures or memory defects prevent normal drive start-up, ABC Industrial Parts provides tested replacement units and repair options to minimize machine downtime.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | E82EV552_2C |
| Component Type | Frequency Inverter |
| Product Family | 8200 Vector |
| Nominal Supply Voltage | 230 V AC |
| Supply Voltage Range | 180 - 264 V AC |
| Input Phases | 3-phase |
| Rated Power (kW) | 5.5 kW |
| Rated Power (HP) | 7.5 HP |
| Rated Output Current | 24 A |
| Output Voltage Range | 0 - 230 V AC |
| Output Frequency Range | 0 - 480 Hz |
| Nominal Switching Frequency | 8 kHz (adjustable up to 16 kHz) |
| Motor Control Modes | Sensorless Vector Control, Torque Control, V/f linear, V/f quadratic |
Programming and Configuration
The Lenze E82EV552_2C utilizes internal non-volatile EEPROM memory capable of retaining up to four independent parameter sets. This feature allows different operational profiles to be stored within a single drive or duplicated directly to replacement drives without losing configuration data during power outages.
Parameter setup and drive commissioning are conducted using either the plug-in Lenze E82ZBC XT Keypad Module or Lenze Global Drive Control (GDC) PC software. Critical parameters include acceleration ramp time (C0012), deceleration ramp time (C0013), and motor nameplate parameters (C0087, C0088, C0089). If a parameter loading conflict or data corruption occurs, resetting parameter C0002 to 1 restores the inverter to factory default values for fresh commissioning.
Communication and System Integration
System integration for the 8200 Vector series relies on a modular function slot designed to accept interchangeable fieldbus and function modules. Supported fieldbus options include CANopen, PROFIBUS-DP, DeviceNet, INTERBUS, and Modbus RTU or LECOM, allowing direct control integration with various PLC platforms.
In addition to serial and fieldbus interfaces, the inverter provides configurable digital outputs for remote signaling of fault conditions and operational readiness. The carrier switching frequency can be adjusted up to 16 kHz to satisfy low-noise motor operation requirements in sensitive ambient environments.
Diagnostics and Status Indication
Visual status indication is provided by dual-color red and green LEDs located on the front of the inverter and on installed function modules. Solid or flashing illuminated patterns signal drive operational readiness, active fault trips, or controller pulse inhibit conditions.
Detailed fault diagnostics are retrieved electronically by inspecting diagnostic parameters. Active fault conditions are displayed in parameter C0161 (current TRIP fault), while historical events are saved in parameter C0168 (TRIP history memory). These parameters are accessible via the E82ZBC XT Keypad Module or dedicated diagnostic windows within Lenze Global Drive Control (GDC) software.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Front / Module LEDs | Red / Green - Solid / Flashing | Displays drive operational status, readiness, active error state, or pulse inhibit condition. |
Replacement and Spare Part Considerations
When swapping out a damaged Lenze E82EV552_2C, ensure the spare drive matches the original 3-phase 230V rating and 24A current output. Installed fieldbus and function modules must be unclipped from the donor frame and mounted into the replacement unit to maintain fieldbus address and physical I/O connectivity.
Parameter sets stored in the original inverter memory must be restored to the replacement unit using the Lenze E82ZBC XT Keypad Module or Global Drive Control (GDC) software. While the 8200 Vector series is an end-of-life legacy product, maintaining duplicate spares allows existing production machinery to remain operational. For future machine retrofits or complete platform upgrades, Lenze recommends migrating to the i550 cabinet frequency inverter series (recommended successor model i55AE255C0000000S).
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit | Short circuit in motor circuit or dynamic motor load peak during acceleration | Short circuit or ground fault in motor cable, motor winding fault, acceleration time too short | Check motor and motor cable for short circuits / ground faults, verify acceleration time setting (C0012). If fault persists with motor disconnected, internal inverter hardware failure requires unit repair or replacement. |
| OC2 | Earth Fault / Deceleration Overcurrent | Earth fault or overcurrent trip during deceleration phase | Earth fault in motor cable/winding, deceleration time setting too short | Inspect motor insulation resistance to ground, extend deceleration time (C0013). |
| OC3 | Overcurrent During Constant Operation | Overcurrent detected during steady-state constant speed operation | Abrupt load changes, motor mechanical overload, motor stall | Check drive mechanics for jamming or severe overload, check motor sizing. |
| OC5 | Overcurrent During Acceleration | Dynamic motor current threshold exceeded during speed ramp-up | Ramp generator time too short, motor parameter mismatch, excess inertia | Increase ramp-up time C0012, check motor nameplate parameter settings (C0087/C0088/C0089). |
| OU | DC Bus Overvoltage | DC bus voltage exceeds overvoltage shutdown threshold (> 400V DC) | Regenerative energy fed back from motor during deceleration, deceleration time too short, missing or defective braking resistor / braking module | Increase deceleration ramp time C0013, install external braking module/resistor if heavy regenerative load. |
| LU | DC Bus Undervoltage | DC bus voltage dropped below minimum operation threshold (< 215V DC) | Supply line voltage failure, phase loss, input voltage drop, loose supply terminal | Check AC line input supply voltage, check line fuses and wiring terminals. |
| OH | Heatsink Overtemperature | Inverter power section / heatsink temperature exceeded maximum limit (> 85°C) | Clogged heatsink fins, internal cooling fan failure, ambient temperature too high, control cabinet ventilation insufficient | Clean heatsink, verify operation of internal fan, improve cabinet ventilation and ambient cooling. |
| OH1 | Motor Overtemperature via PTC | Motor thermistor/PTC connected to terminals T1/T2 triggered overtemperature alarm | Motor thermal overload, cooling fan failure on motor, heavy low-speed operation without forced cooling | Allow motor to cool, reduce mechanical load, verify motor forced cooling fan. |
| OH3 | Motor I2t Overtemperature | Calculated motor load thermal integral (I2t) exceeded threshold | Continuous operation at overcurrent level without sufficient pause | Check motor operating current vs rated current, adjust I2t monitoring parameters (C0075/C0076). |
| OH7 | Motor Temperature Sensor Wire Break | Open circuit detected on thermistor/PTC evaluation input terminals T1/T2 | Broken signal wire, loose terminal connection, defective PTC sensor | Check sensor wire continuity and connections at terminals T1 and T2. |
| EE | EEPROM Memory Fault | Checksum error or read/write defect in internal non-volatile EEPROM memory | Power interruption during parameter write, internal EEPROM chip failure | Reload factory default settings (C0002 = 1). If fault cannot be cleared, internal board-level hardware failure requires unit replacement. |
| IMP | Pulse Inhibit | Inverter output power stage inhibited (normal status or interlock) | Terminal CINH (Controller Inhibit / Terminal 28) is open/deasserted, or active fault inhibits pulses | Apply high signal (+24V) to Terminal 28 (CINH) to enable inverter driver output. |
| NMAX | Maximum Speed Exceeded | Actual motor speed exceeded configured maximum speed limit C0011 | Incorrect feedback setup, field weakening overspeed, overhauling load | Check maximum speed parameter limit C0011, check speed feedback and control tuning. |
| P08 | Motor Phase Failure | One of the three motor output phases U, V, W is interrupted | Loose motor cable terminal connection, open motor winding, output contactor opened during operation | Check output wiring continuity across all three motor phases U, V, and W. |
| LP1 | Mains Phase Failure | Loss of single input phase on 3-phase AC line feed | Blown input fuse, loose line connection, supply phase asymmetry | Check 3-phase mains supply voltage and input fuses. |
| C03 | Inconsistent Parameter Set | Parameter set loaded into memory contains invalid or conflicting parameter combination | Incompatible parameter download from different firmware version or power rating | Reset parameters to factory default values (C0002 = 1) and re-commission. |
Frequently Asked Questions
What are the power and voltage ratings for the Lenze E82EV552_2C drive?
The Lenze E82EV552_2C operates on a 3-phase AC supply voltage between 180V and 264V AC (nominal 230V AC) and provides a rated power output of 5.5 kW (7.5 HP) with a continuous output current of 24A.
How do I transfer parameter settings to a replacement drive?
Parameter sets can be uploaded from the internal EEPROM of the old unit and cloned into the replacement drive using either the plug-in Lenze E82ZBC XT Keypad Module or Lenze Global Drive Control (GDC) software.
What motor control modes are available on this inverter?
The inverter supports sensorless vector control, torque control, linear V/f control, and quadratic V/f control.
How can I resolve an EEPROM fault (Code EE) or parameter inconsistency (Code C03)?
Reset the drive to factory defaults by setting parameter C0002 to 1 and re-commission the unit. If the EE code persists after resetting defaults, an internal memory chip failure is indicated, requiring hardware repair or unit replacement.
What is the recommended modern successor for the legacy E82EV552_2C?
Lenze recommends migrating legacy 8200 Vector installations to the modern i550 cabinet frequency inverter series using part number i55AE255C0000000S.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.