Lenze E82EV753K4B201 8200 Vector 7.5 kW Frequency Inverter

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze E82EV753K4B201 is a 7.5 kW frequency inverter from the 8200 Vector series designed for precise speed and torque regulation of three-phase AC industrial motors. Operating across a broad supply voltage range of 320 V AC to 528 V AC, this IP20-rated variable frequency drive delivers a rated output current of 16.5 A with a 150% heavy-duty overload capability reaching 24.8 A for up to 60 seconds. This specific variant (201) is built without an integrated radio frequency interference (RFI) filter, making it ideal for control cabinet installations that employ external line filters or centralized EMC suppression. The unit supports versatile motor control methods, including sensorless vector control alongside linear and quadratic V/f characteristic curves, with an output frequency range from 0 to 480 Hz.
Integrating a replacement drive into an operational machine requires matching physical communication modules and transferring the application parameter configuration. The 8200 Vector series features a modular architecture that accepts plug-in fieldbus options, such as the E82ZAFCC CANopen module, E82ZAFPC PROFIBUS-DP module, and E82ZAFAC RS485 LECOM module, as well as System Bus CAN and RS-232 interfaces. Commissioning a replacement unit is straightforward thanks to the detachable Electronic Programmable Module (EPM), a plug-in hardware memory chip that enables direct parameter cloning without connecting software. Drive setup can also be managed using the optional XT Keypad (E82ZBC) or Lenze Global Drive Control (GDC) PC software. ABC Industrial Parts can assist maintenance teams with parameter extraction from donor units and selecting matching replacement hardware.
Real-time diagnostic feedback is provided on the front panel by dual LED status indicators, where a green LED signals operational readiness and a red LED alerts operators to an active trip or fault condition. When accessed via the XT Keypad or GDC software, the drive reveals a comprehensive fault history buffer detailing trip events such as output overcurrent (OC1–OC4), DC bus overvoltage (OU) or undervoltage (LU), heatsink and motor thermal overload (OH, OH4, OH7, OH8), input phase failure (LP1), and parameter errors (InE, PEr). Practical first-line troubleshooting involves measuring line input voltages across all phases, verifying cooling airflow, and confirming EPM memory chip seating. Internal power stage or control board failures cannot be repaired on-site; acquiring a tested exchange unit or utilizing professional repair through ABC Industrial Parts provides a fast route to restoring production.
Technical Specifications
| Manufacturer | Lenze |
| Part number | E82EV753K4B201 |
| Model / Type | 8200 Vector E82EV753K4B201 |
| Component type | Frequency Inverter |
| Rated power output | 7.5 kW |
| Supply voltage range | 320 - 528 V AC |
| Rated output current | 16.5 A |
| Maximum output current (60s overload) | 24.8 A |
| Output frequency range | 0 - 480 Hz |
| Switching frequency | 8 kHz |
| Control method | Sensorless Vector Control / Linear V/f / Quadratic V/f |
| Protection rating | IP20 |
| Integrated RFI filter | None (Variant 201) |
Programming and Configuration
Parameter management on the Lenze E82EV753K4B201 centers on the plug-in Electronic Programmable Module (EPM). The EPM chip functions as a removable hardware memory store for all drive parameters. Maintenance technicians can clone parameters offline or transfer an existing EPM chip directly from a failed unit into a replacement inverter, restoring complete drive functionality in seconds without requiring a programming cable or software connection.
For direct manual parameterization, the drive supports the plug-in Lenze XT Keypad (E82ZBC). Alternatively, advanced setup, real-time monitoring, and parameter archiving can be performed on a PC using Lenze Global Drive Control (GDC) software. If parameter corruption occurs or illegal parameter combinations are configured, a factory reset command can restore default settings before re-commissioning.
Communication and System Integration
The 8200 Vector architecture features a flexible interface slot for fieldbus integration. The E82EV753K4B201 accepts multiple interchangeable communication modules, allowing the inverter to fit seamlessly into diverse automation networks. Supported options include the E82ZAFCC CANopen module, E82ZAFPC PROFIBUS-DP module, and E82ZAFAC RS485 LECOM module, as well as System Bus CAN and RS-232 serial interfaces.
These plug-in modules enable the drive to accept remote start/stop commands, velocity setpoints, and torque limits while returning operational status and trip alarms to a central PLC. When replacing a drive in a networked system, transferring the communication module from the original drive ensures hardware interface compatibility and retains existing network address settings.
Diagnostics and Status Indication
Visual operational status is provided via two status LEDs on the front panel of the E82EV753K4B201. The green LED indicates power and operational readiness, flashing or remaining solid depending on the drive state. The red LED illuminates solid when a drive fault or trip condition occurs, indicating an active fault that requires inspection or a manual reset.
Detailed trip diagnostics are logged in an internal fault history buffer accessible using the optional XT Keypad or Global Drive Control (GDC) software. The buffer retains recent error codes, helping technicians trace specific electrical, thermal, or operational trips during fault analysis.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Green LED (Ready) | Green - Solid / Blinking depending on state | Inverter operational, ready for operation / running status |
| Red LED (Fault) | Red - Solid | Drive fault or trip condition present; active fault requiring action or reset |
Replacement and Spare Part Considerations
When replacing an existing Lenze E82EV753K4B201 drive, confirm the exact variant identifier. Suffix 201 signifies that the inverter is built without an internal RFI filter. If replacing a unit in a panel that relies on central line filtering, installing a drive variant with an integrated filter could alter panel leakage currents or grounding schemes.
Commissioning a spare drive requires moving both the plug-in communication option card and the EPM parameter memory module from the failed inverter to the replacement unit. Always verify that the EPM chip is fully seated in its front panel slot before powering on the drive. Although Lenze has phased out the legacy 8200 Vector family in favor of the modern i550 series, direct replacement units remain essential for maintaining established machinery without modifying control wiring or PLC programs.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit | Short circuit or ground fault detected on motor output terminals | Short circuit in motor cable; inter-phase short circuit in motor; ground fault in motor winding or cable | Check motor cable for damaged insulation or short circuit; check motor windings with megohmmeter; inspect for internal drive damage if fault persists with motor disconnected |
| OC2 | Overcurrent during Acceleration | Output current limit exceeded during motor acceleration phase | Acceleration time set too short; motor undersized for load; excessive load inertia | Increase acceleration time setting; verify motor sizing and load requirements; check motor parameter data in inverter |
| OC3 | Overcurrent during Deceleration | Output current limit exceeded during motor deceleration phase | Deceleration time set too short; brake chopper not functioning or brake resistor value incorrect | Increase deceleration time; check external brake chopper circuit and brake resistor |
| OC4 | Overcurrent during Constant Operation | Output current limit exceeded during steady-state running | Sudden mechanical load shock; mechanical jam/blockage; motor under-powered for application | Check mechanical driven machinery for jams or binding; verify load torque requirements |
| OU | DC Bus Overvoltage | DC bus voltage exceeded safe maximum threshold | Excessive regenerative energy from motor during deceleration; deceleration time too short; brake resistor open or disconnected | Increase deceleration ramp time; check external brake resistor and wiring; verify mains voltage within spec |
| LU | DC Bus Undervoltage | DC bus voltage dropped below minimum operational threshold | Mains supply voltage failure or dip; phase loss on AC input line; main power contactor drop-out | Measure input AC line voltage across all phases; check input supply fuses and wiring connections |
| OH | Heatsink Overtemperature | Inverter heatsink temperature exceeds maximum permitted limit | Insufficient cooling airflow; cooling fan failure or blocked heatsink fins; ambient temperature exceeds limit | Clean heatsink cooling fins; verify enclosure fan operation; improve control cabinet ventilation |
| OH4 | Heatsink Thermal Warning / Limit | Heatsink temperature approaching maximum thermal limit | High ambient temperature; continuous heavy loading; restricted ventilation | Reduce drive load or switching frequency; clean enclosure air filters and heatsink |
| OH7 | Motor Temperature Sensor (PTC) | Motor thermistor/PTC contact triggered overtemperature condition | Motor thermal overload; insufficient motor cooling; defective PTC sensor wiring | Allow motor to cool down; check motor ventilation/fan; verify PTC sensor resistance |
| OH8 | Motor Thermal Overload (I2t) | Calculated motor thermal overload state based on I2t monitoring model | Continuous operation at low speed under high load without forced ventilation; incorrect motor full load current parameter | Verify motor current parameter settings; install forced cooling fan on motor for low-speed operation |
| InE | Internal Fault / EPM Memory Error | Internal hardware failure or missing/corrupted EPM parameter module | EPM module not inserted properly; corrupted parameter data in EPM chip; internal control board failure | Ensure EPM chip is securely seated in front socket; reload parameter data into EPM; if fault persists, return unit for repair or replace inverter |
| PEr | Program / Parameter Error | Inconsistent or illegal parameter combination configured in EPM | Incompatible parameter configuration downloaded; parameter range out of bounds | Perform factory parameter reset (load default settings); re-commission drive parameters using GDC software or keypad |
| EEr | External Fault Triggered | Fault signal received via digital input programmed for external fault trip function | External monitoring device (safety relay, thermal switch, external trip contact) opened | Check external signal chain connected to the programmed digital input terminal |
| LP1 | Mains Input Phase Failure | Loss of one phase on 3-phase AC input supply | Blown input line fuse; loose wire connection on L1, L2, or L3 terminals; severe supply voltage unbalance | Check input fuses and measure AC line voltage across all three incoming mains phases |
| NMAX | Overspeed Protection | Motor actual speed exceeded maximum permitted threshold | Overhauling load driving motor faster than set limit; incorrect encoder feedback parameterization | Verify load mechanics and overhauling torque; check max frequency and speed limits |
Frequently Asked Questions
How do I transfer drive parameters to a replacement Lenze E82EV753K4B201?
Parameter transfer is accomplished by removing the plug-in EPM memory chip from the front panel of the original drive and inserting it directly into the replacement inverter. Drive parameters can also be loaded using Lenze Global Drive Control (GDC) software or programmed via the XT Keypad.
Does the E82EV753K4B201 variant include an internal RFI filter?
No, the 201 variant suffix indicates that this model is manufactured without an integrated RFI filter. It is intended for systems that utilize external line filters or central cabinet filtering.
Which fieldbus interfaces are compatible with this drive?
The 8200 Vector series accepts interchangeable plug-in communication modules including CANopen (E82ZAFCC), PROFIBUS-DP (E82ZAFPC), and RS485 LECOM (E82ZAFAC), alongside System Bus CAN and RS-232 interfaces.
What should I check if the drive indicates an InE fault code?
An InE fault code signifies an internal fault or EPM memory error. Verify that the EPM memory chip is firmly inserted into its socket. If the module is properly seated, reload the parameter data or perform a factory reset. Persistent InE errors point to internal control circuit failure.
What is the modern replacement path for the Lenze 8200 Vector series?
Lenze recommends the i550 series as the official successor to the phased-out 8200 Vector range. However, exact original replacement units like the E82EV753K4B201 allow direct drop-in maintenance without panel modification or software re-engineering.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.