Lenze EVF9330-EHV004 9300 Vector Frequency Inverter 45 kW / 60 HP

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Series | Series: 9300 Vector

The Lenze EVF9330-EHV004 is a panel-mounted 9300 Vector frequency inverter designed for high-performance dynamic motor control in automated processing and manufacturing machinery. Operating across a 3-phase supply range of 320 to 528 V AC, this drive delivers a rated output power of 45 kW (60 HP) with a continuous output current of 89 A at 400 V AC and 74 A at 480 V AC. It supports linear and square V/f characteristic control, sensorless vector control, and closed-loop vector control with encoder speed feedback, operating at an 8 kHz switching frequency over an output frequency range of 0 to 480 Hz. The V004 specification designates a model supplied without an internal radio interference filter, intended for enclosure configurations that rely on centralized external EMC filtering.

Connecting and commissioning a replacement EVF9330-EHV004 unit requires transferring motor parameters and application settings before putting the drive into service. The drive features an integrated CAN System Bus operating at up to 500 kbit/s for multi-axis synchronization, alongside a modular Automation Interface slot that accepts optional communication modules such as PROFIBUS-DP, CANopen, DeviceNet, or Modbus RTU. Up to four complete parameter sets can be stored in non-volatile EEPROM memory. Technical personnel can configure parameter sets using Lenze Global Drive Control software connected via an EMF2177IB USB-to-CAN adapter or transfer parameters directly using the optional EMZ9371BB keypad operating module. When migrating configuration from a damaged drive, ABC Industrial Parts can assist with parameter extraction or supplying pre-configured replacement drives to restore production quickly.

Diagnostic status is indicated directly on the front panel by three LED indicators showing ready status, active faults, and controller inhibition. An internal memory buffer logs the eight most recent fault codes along with operating hour timestamps, while real-time diagnostic parameters monitor DC link voltage, output current, motor frequency, and heatsink temperature. Initial field checks for common trips such as overcurrent or bus undervoltage include verifying 3-phase input line power, checking motor winding insulation, and assessing braking resistor circuits. If critical hardware faults occur, such as EE0, EER, or H05, internal memory or driver circuit failures are indicated that cannot be serviced in the field. Under these conditions, exchanging the unit with a tested replacement from ABC Industrial Parts offers a fast and dependable route back to full operation.

Technical Specifications

Rated Power (400V)45 kW
Rated Power (480V)60 hp
Supply Voltage Range320 - 528 V AC
Rated Input Current (400V)85 A
Rated Input Current (480V)71 A
Continuous Output Current (400V)89 A
Continuous Output Current (480V)74 A
Maximum Output Current133.5 A (150% overload for 60 s)
Radio Interference FilterWithout Filter (Variant V004)
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz
Control MethodV/f Characteristic, Sensorless Vector Control, Closed-Loop Vector Control
Integrated InterfaceCAN System Bus (500 kbit/s)
Mounting TypePanel Mount / Cabinet Installation

Programming and Configuration

The Lenze EVF9330-EHV004 frequency inverter incorporates non-volatile EEPROM memory capable of retaining up to four independent, switchable parameter sets. Drive setup, motor profiling, and parameter management are performed primarily through Lenze Global Drive Control (GDC) software or via the optional pluggable EMZ9371BB keypad operating module.

During commissioning or unit replacement, parameter configurations must be loaded to align with motor thermal characteristics, control modes, and fieldbus communication settings. In the event of a parameter checksum fault (code PR0), the drive parameters can be restored to factory defaults by setting code C0002 to 1, after which valid project parameter files can be reloaded into the active set.

Communication and System Integration

System integration for the EVF9330-EHV004 is supported by an onboard CAN System Bus interface operating at communication rates up to 500 kbit/s. This system bus provides rapid inter-drive cross-linking and multi-axis synchronization across continuous machinery processes without requiring extra network hardware.

For integration into broader industrial automation networks, the inverter features a plug-in Automation Interface (AIF) slot. Optional communication modules, such as the EMF2133IB for PROFIBUS-DP or the EMF2176IB for CANopen, enable fieldbus connection to host PLCs and control systems. Software programming and direct PC diagnostic links are facilitated using the EMF2177IB USB-to-CAN adapter.

Diagnostics and Status Indication

Real-time operating diagnostics on the EVF9330-EHV004 are provided by three front-panel status LEDs: DRIVE READY (green), ERROR (red), and IMP (yellow). These status indicators communicate ready states, fault trips, warning alerts, and active controller pulse inhibition.

Detailed troubleshooting is supported by an onboard fault history buffer storing up to eight recent diagnostic events complete with operating hours timestamps. Maintenance personnel can inspect operational parameters, including DC bus voltage, output current, motor frequency, and heatsink temperature via Global Drive Control software or through the pluggable EMZ9371BB keypad display.

Status LED Indicators

LEDColor/StatusMeaning
DRIVE READYGreen - Solid or FlashingSolid green indicates inverter is ready for operation or running; blinking indicates initialization or controller inhibit active.
ERRORRed - Solid or FlashingSolid red indicates active fault trip (drive disabled); blinking indicates warning active.
IMPYellow - SolidSolid yellow indicates controller inhibit active (output power pulses blocked).

Replacement and Spare Part Considerations

When replacing an installed Lenze EVF9330-EHV004 inverter, confirm that the replacement drive shares the identical V004 suffix specification. Because the V004 model is built without an integrated radio interference filter, installing a drive with internal filtration or different electrical characteristics into an enclosure designed for centralized external filtering can lead to improper grounding or EMC non-compliance.

Before applying power to a new unit, transfer the existing parameter sets from the faulty drive or back-up software project using Lenze Global Drive Control or the EMZ9371BB keypad module. Ensure that optional communication cards installed in the Automation Interface slot are properly seated and configured with matching node addresses and transmission speeds.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short Circuit / Acceleration OvercurrentOutput current exceeded peak limit during acceleration phaseShort circuit or earth fault at motor output terminals, motor cable length too long, acceleration ramp time too shortCheck motor wiring and insulation, verify motor parameters, increase acceleration ramp time
OC2Deceleration OvercurrentOutput current exceeded peak limit during deceleration phaseDeceleration ramp time too short, brake chopper not connected or defectiveIncrease deceleration ramp time, verify operation of braking resistor / chopper module
OC3Steady-State OvercurrentOutput current exceeded peak limit during continuous steady operationSudden mechanical load surge, motor mechanical blockage, unstable control loopCheck driven machine for mechanical binding or jam, check motor parameter settings
OC5Earth FaultGround fault current detected on output terminalsEarth fault in motor cable or motor winding, capacitive leakage currentCheck motor winding insulation and motor power cables with megohmmeter
OUDC Bus OvervoltageDC link voltage exceeded upper threshold limit (~770 V DC)Regenerative energy from motor during braking, mains supply voltage too high, brake resistor open circuitCheck mains line voltage, check braking resistor value and wiring, extend deceleration time
LUDC Bus UndervoltageDC link voltage dropped below minimum operation limit (~285 V / ~430 V DC)Mains supply failure, voltage sag, blown input fuse, main contactor openCheck 3-phase incoming supply voltage, supply fuses, and power connections
OHHeatsink OvertemperatureInverter heatsink temperature exceeded thermal shutdown limit (~90°C)Dirty or clogged heatsink fins, defective cooling fan, ambient temperature too highClean heatsink, verify cooling fan operation and cabinet ventilation
OH3Internal OvertemperatureInternal temperature inside inverter enclosure exceeded limitInsufficient enclosure air circulation, ambient temperature excessiveImprove control cabinet cooling and ventilation
OH4Motor Overtemperature SensorMotor thermal contact / PTC connected to terminals T1/T2 triggeredMotor thermal overload, insufficient motor cooling, defective PTC sensor wireAllow motor to cool down, reduce motor load, check sensor wiring
OH7Calculated Motor Thermal Overload (I2t)Inverter thermal motor model calculated excessive heat accumulationContinuous operation at high current / low speed without forced coolingCheck motor sizing, reduce continuous motor load, install external motor cooling fan
OH8Calculated Inverter Overload (I2t)Inverter power section thermal utilization limit reachedFrequent heavy duty cycles or high switching frequency under continuous loadReduce switching frequency or select larger power rated frequency inverter
LP1Mains Phase FailureOne phase of the 3-phase AC mains supply is missingBlown input fuse, loose supply wiring terminal, unbalanced grid supplyCheck all 3 input phases for balanced AC voltage and check mains fuses
CE0System Bus (CAN) Communication FaultTime-out or cyclic frame reception error on CAN system bus interfaceBroken CAN bus cable, missing 120 ohm terminating resistors, node offlineCheck CAN wiring, shield grounding, bus termination, and baud rate settings
CE1AIF Module Fault Slot 1Communication failure between inverter control board and option module in AIF slotAIF module loose, fieldbus master stopped communication, module defectiveCheck fieldbus cabling and master unit; re-seat AIF communication module
EE0Internal EEPROM ErrorRead or write error in internal non-volatile EEPROM memoryInternal hardware failure — EEPROM corrupt or failingInternal hardware fault — perform factory load default settings; if fault persists, return unit for repair
EERInternal RAM ErrorInternal RAM memory check failed during startup self-testInternal memory hardware errorInternal board failure — non-field serviceable, return unit for repair
H05Internal Power Hardware ErrorHardware fault in gate driver or power section monitoring circuitInternal driver board failure, damaged power module (IGBT)Internal hardware failure — replace unit or contact Lenze service center for repair
PERProgram Memory Checksum ErrorEPROM program memory checksum verification failedCorrupted firmware or micro-controller circuit faultInternal hardware failure — replace unit or contact Lenze service center for repair
PR0Parameter Set ErrorParameter checksum fault or invalid value loaded into active setInterrupted parameter transfer or incomplete memory writeRe-initialize drive parameters to factory defaults (C0002 = 1) and reload parameters
SBRSpeed Feedback Signal FailureLoss or breakdown of resolver or incremental encoder signalBroken encoder cable, loose connector, encoder supply failureCheck encoder cable connection, power supply to sensor, and feedback channel wiring

Frequently Asked Questions

What does the V004 variant code mean on the Lenze EVF9330-EHV004?

The V004 variant designation indicates that the frequency inverter is manufactured without an integrated radio interference filter. It is intended for installation in electrical cabinets that use centralized external EMC line filtering.

How are parameters transferred to a replacement EVF9330-EHV004 drive?

Parameter sets stored in the EEPROM memory can be saved and transferred using Lenze Global Drive Control (GDC) software via an EMF2177IB USB-to-CAN adapter, or directly copied using an optional pluggable EMZ9371BB keypad module.

Which fieldbus communication options are available for this drive?

The inverter includes an integrated CAN System Bus operating up to 500 kbit/s. Additional protocols including PROFIBUS-DP, CANopen, DeviceNet, INTERBUS, and Modbus RTU are supported via option modules installed in the Automation Interface (AIF) slot.

What does a solid yellow IMP LED indicate on the inverter?

A solid yellow IMP LED indicates that controller inhibit is active. In this state, output power pulses to the motor are blocked and the drive is prevented from energizing the motor.

Can internal memory or board fault codes like EE0 or EER be fixed on site?

Fault codes EE0 (internal EEPROM error), EER (internal RAM error), and H05 (internal power hardware error) represent board-level hardware failures. These errors cannot be repaired in the field and require replacing the drive or returning the unit for professional repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.