Lenze EVS9325-CKV003 9300 Servo Cam Profiler Controller

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300 Servo Cam Profiler

The Lenze EVS9325-CKV003 is a 5.5 kW servo controller from the 9300 Servo family, specifically designed as a 9300 Servo Cam Profiler unit with integrated V003 application firmware. Operating on a nominal 400 V AC 3-phase supply with an allowable voltage range of 320 to 528 V AC, this IP20-rated drive delivers a continuous rated current of 13 A and a peak output current of 19.5 A at an 8 kHz switching frequency. Its cold-plate mounting design dissipates heat through external cooling surfaces or heat sinks, keeping electrical enclosure cabinet dimensions compact.

Interfacing the unit with external machinery relies on a Sub-D 9-pin resolver connection, master frequency and encoder inputs, as well as simulated encoder outputs for synchronized multi-axis control. Communication across drive systems is driven by an onboard System Bus CAN interface, supplemented by an Automation Interface (AIF) slot that supports option cards such as the EMF2133IB PROFIBUS-DP or EMF2173IB CANopen modules. When commissioning a replacement unit, parameter sets stored in the original controller must be loaded into the spare unit using Lenze Global Drive Control (GDC) software or the plug-in EMZ9371BC keypad module. Because the onboard firmware executes electronic cam profiles directly, aligning software parameters, motor feedback calibration, and module addresses is required to ensure proper operation. Technical specialists at ABC Industrial Parts can assist in parameter extraction and configuration verification when replacing operational drives.

Diagnostic conditions are reported via two front-facing LEDs: a green DRIVE READY status indicator that remains solid during normal operation and a red DRIVE ERROR / TRIP LED that flashes or stays solid when a fault is active. Detailed error conditions, such as short circuits (OC1), DC link overvoltage (OU), motor feedback errors (SD7), or electronic cam tracking errors (P12), can be examined through the EMZ9371BC keypad display or monitored remotely using GDC software and the internal trip history buffer. While external issues such as cable faults, line phase losses, or parameter errors can be resolved during routine maintenance, unresolvable system errors like internal hardware failures (H05) or severe EEPROM corruption (EEr) indicate internal component defects. In these cases, contacting ABC Industrial Parts for a tested exchange unit or professional repair service helps restore production quickly.

Technical Specifications

ManufacturerLenze
Part NumberEVS9325-CKV003
Model / Type9300 Servo Cam Profiler
Product Family9300 Servo
Component TypeServo Controller
Rated Power5.5 kW
Nominal Supply Voltage400 V AC
Supply Voltage Range320 - 528 V AC
Continuous Rated Current13 A
Peak Output Current19.5 A
Switching Frequency8 kHz
Output Frequency Range0 - 480 Hz
Mounting TypeCold Plate
IP RatingIP20
Digital Inputs5
Digital Outputs4
Analog Inputs2
Analog Outputs2

Programming and Configuration

The EVS9325-CKV003 servo controller operates using integrated V003 Cam Profiler application firmware, allowing complex electronic camming functions and synchronized motion sequences to execute directly within the drive logic. Parameterization and system commissioning are conducted through Lenze Global Drive Control (GDC) software connected via serial LECOM or fieldbus interfaces, or locally using the plug-in EMZ9371BC operating keypad module with its 8-character display.

The drive memory structure supports up to four complete, independent parameter sets stored internally. Transferring parameter data to a spare unit during drive replacement requires retrieving the active configuration via GDC software or backing up the parameter file from the original controller. Re-establishing feedback scaling, resolver pole configurations, and motion control tolerance bands is necessary before restoring power to the system output stage.

Communication and System Integration

System-level integration for the Lenze EVS9325-CKV003 is driven by its integrated System Bus CAN interface, which provides direct drive-to-drive inter-axis synchronization and rapid parameter exchange across multi-axis motion networks. Physical connections require 120-ohm bus termination resistors at both physical ends of the communication line to ensure network integrity.

For high-level industrial fieldbus integration, the unit includes an Automation Interface (AIF) front expansion slot. This slot accepts option cards such as the EMF2133IB for PROFIBUS-DP networks and the EMF2173IB for CANopen protocols, as well as modules for LECOM RS-232/RS-485 and Interbus. Additionally, the drive provides 5 digital inputs, 4 digital outputs, 2 analog inputs, and 2 analog outputs for direct wiring to localized machine sensors and control signals.

Diagnostics and Status Indication

The EVS9325-CKV003 provides visual and digital diagnostic reporting to streamline troubleshooting. Front-panel LED status indicators offer immediate feedback on operating states, while detailed numerical trip codes are transmitted to the EMZ9371BC keypad display or logged inside the drive internal trip history memory buffer accessible through Lenze GDC software.

Status LED Indicators

LEDColor/StatusMeaning
DRIVE READYGreen - SolidOperational state indication; solid illuminated when drive controller is initialized and ready for operation.
DRIVE ERROR / TRIPRed - Flashing / SolidFault indication; flashing or solid illuminated when a drive fault or trip condition is active.

Replacement and Spare Part Considerations

When substituting an existing Lenze EVS9325-CKV003 servo controller, maintenance teams must verify that the cold-plate mounting surface is properly prepared with suitable thermal conduction compound or mounted flush against compatible cooling plates. Physical dimensions and the IP20 enclosure rating require adequate cabinet space and proper heat exchange to prevent thermal trips.

Because motion profiles and axis synchronization parameters are stored in internal non-volatile memory, a replacement unit cannot function out of the box without parameter transfer. Operating teams must ensure that motor resolver feedback connections, fieldbus module seating in the AIF slot, and network baud rate configurations match the original installation prior to enabling the drive output.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / Earth faultShort circuit or earth fault detected on inverter output terminals (U, V, W).Short circuit in motor power cable, motor winding fault, ground fault in wiring.Disconnect motor cables and test insulation resistance. If fault persists with motor disconnected, internal power stage failure requires unit repair or replacement.
OC2Earth faultEarth fault detected on motor connection or motor winding.Insulation breakdown to protective earth in motor cable or motor stators.Inspect motor cables and motor winding insulation resistance to earth.
OC5Overcurrent during accelerationDrive current limit exceeded during dynamic acceleration phase.Acceleration time too short, mechanical stall or jam, excessive load inertia.Increase acceleration time ramp, check mechanical system for binding, verify motor sizing.
OUDC bus overvoltageDC bus voltage exceeded maximum allowable voltage threshold.Regenerative energy from motor during deceleration too high, brake resistor disconnected or defective.Extend deceleration time, verify brake module operation and braking resistor resistance value.
LUDC bus undervoltageDC link voltage dropped below minimum operating limit.AC line supply failure, supply line voltage drop, missing input phase.Check AC line supply voltage, input fuses, and line reactor connection.
OHHeatsink overtemperatureDrive heat sink temperature exceeded maximum safety threshold.Insufficient cooling surface contact, thermal paste degradation, ambient temperature too high.Verify cold-plate mounting surface thermal contact, clean cooling channels, reduce ambient enclosure temp.
OH3Motor thermal overload (PTC/TK)Motor temperature sensor input triggered overtemperature fault.Motor thermal overload, cooling fan failure on motor, open circuit in thermistor cable.Allow motor to cool down, inspect motor cooling, verify PTC/TK sensor wire integrity.
OH4Drive internal overtemperatureTemperature inside the drive enclosure exceeded limit.Inadequate control cabinet ventilation or excessive ambient temperature.Improve control cabinet ventilation and heat dissipation.
OH7Motor thermal model limit (I2t)Calculated motor thermal loading (I2t) reached 100%.Continuous operation above rated motor current.Reduce continuous mechanical load or verify motor parameter settings in drive.
OH8Inverter thermal model limit (I2t)Calculated drive thermal load limit reached maximum limit.Drive operating near peak current limit for prolonged period.Reduce dynamic duty cycle or upgrade to higher power drive rating.
CE0AIF communication errorCommunication breakdown between control board and fieldbus module in AIF slot.Loose fieldbus card, fieldbus network fault, master PLC communication stop.Check fieldbus module mechanical seating, fieldbus master status, and network cabling.
CAN-E0System Bus CAN bus-off / communication errorSystem Bus CAN interface error or bus-off state.CAN wiring short circuit, wrong baud rate, missing 120 ohm termination resistors.Verify CAN low/high wiring, check 120 ohm line termination at both bus ends.
EErEEPROM memory checksum errorInternal EEPROM data corruption during initialization or save cycle.Power interruption during parameter save, non-volatile memory cell defect.Reload factory default parameters and reconfigure. If fault persists, internal board failure requires unit repair.
H05Internal hardware failureInternal self-test or hardware safety monitor detected hardware defect.Control board failure, internal power supply drop.Internal hardware fault — non-serviceable. Return unit for repair or replace drive.
NMAXMotor overspeed faultActual motor speed exceeded configured NMAX threshold.Speed feedback signal noise, unstable control loop, runaway load.Check resolver/encoder cabling and shield connection, tune speed loop parameters.
SD7Feedback encoder / resolver errorResolver or incremental encoder feedback signal lost or corrupted.Feedback cable broken, unplugged connector, bad resolver winding or encoder pulse train.Check feedback connector pin alignment, wiring, shield grounding, and feedback sensor.
P12Cam profile / Following error faultPosition tracking error exceeded programmed tolerance band during cam profile execution.Mechanical blockage, dynamic acceleration mismatch, cam profile data corruption.Inspect mechanics, recalculate cam profile parameters in GDC software, adjust gain settings.
LP1Line supply phase lossLoss of one incoming phase on 3-phase AC input terminals.Blown input fuse, loose line connection, severe main voltage imbalance.Check input supply line phase voltages under load and check supply line fuses.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze EVS9325-CKV003 drive?

Configuration data can be uploaded from the original drive and downloaded to the replacement unit using Lenze Global Drive Control (GDC) software. Alternatively, parameters saved in an EMZ9371BC operating keypad module can be transferred directly to the replacement controller.

What mounting requirements apply to the cold-plate version of this servo controller?

The EVS9325-CKV003 features a cold-plate thermal design, meaning it must be securely mounted against an external heat sink or liquid-cooled panel using thermal paste to maintain adequate heat dissipation.

Which fieldbus communication modules are compatible with the EVS9325-CKV003?

The integrated Automation Interface (AIF) expansion slot supports option cards including the EMF2133IB module for PROFIBUS-DP, the EMF2173IB module for CANopen, as well as LECOM RS-232/RS-485 and Interbus interfaces.

What action should be taken if fault code H05 appears on the keypad display?

Fault code H05 indicates an internal hardware failure detected by internal safety monitoring circuits. This condition cannot be repaired in the field and requires unit repair or controller replacement.

What motor feedback options are supported by the Lenze 9300 Servo Cam Profiler?

The controller supports feedback from 2-pole and multi-pole resolvers connected via a Sub-D 9-pin terminal, as well as incremental encoders and master frequency input signals.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.