Lenze 9324MP.VB.61 Control Board – 9300 Servo Series

New 
On request
Refurbished   
2 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300 Series

The Lenze 9324MP.VB.61 is a revision VB.61 microprocessor control board engineered for Lenze 9300 Series servo drives and Servo PLCs. Mounted directly onto 3.0 kW Lenze 9324 servo drive power sections operating with a 7 A rated output current, this card functions as the main processing core for closed-loop speed control, positioning, and torque regulation in automated industrial machinery. Operating on an 18 to 32 V DC (24 V DC nominal) control supply voltage, the board integrates multi-axis system bus capabilities and modular fieldbus connectivity designed for precision motion control applications.

Connecting a replacement 9324MP.VB.61 into service requires matching physical interfaces and transferring configuration data from the original unit. External connections include +/-10V differential analog setpoint inputs, 24V DC digital inputs and status outputs, a 9-pin Sub-D feedback interface for resolver or encoder inputs, and a 33-pin Automation Interface (AIF) slot for plug-in fieldbus modules. Onboard non-volatile EEPROM retains up to four independent parameter sets (PAR1 to PAR4), allowing parameter cloning via an EMZ9371BC keypad or Lenze Global Drive Control (GDC) software. Commissioning a replacement unit requires restoring parameter backups to maintain proper motor and application tuning, with ABC Industrial Parts providing tested replacement boards and configuration transfer support.

Diagnostic information is indicated directly on the front panel via status LEDs, supported by internal diagnostic flags and an integrated TRIP buffer fault memory. The green Ready LED remains solid during active operation with controller enable and flashes when controller inhibit (CINH) is active. The red Fault LED indicates an active TRIP condition when solid or an active warning message when flashing. Fault codes such as H05 internal hardware failures or EER parameter memory corruption indicate board-level faults that are not field-serviceable, requiring control card replacement to restore production, a process supported through ABC Industrial Parts.

Technical Specifications

ManufacturerLenze
Part Number9324MP.VB.61
Model / TypeControl Board (Revision VB.61)
Component TypeServo Drive Control Board
Product Family9300 Servo
Compatible Power SectionLenze 9324 (3.0 kW)
Rated Power3.0 kW
Rated Output Current7 A
Control Supply Voltage24 V DC (18 - 32 V DC)
System BusCAN System Bus (500 kbit/s)
Automation Interface33-pin AIF Slot
Feedback Interface9-pin Sub-D (Resolver / Encoder)
Parameter Memory4 Parameter Sets (Non-volatile EEPROM)

Programming and Configuration

Drive configuration and parameter management on the Lenze 9324MP.VB.61 control board are performed using Lenze Global Drive Control (GDC) PC software or an EMZ9371BC plug-in operating keypad. Onboard non-volatile EEPROM memory stores up to four separate parameter sets (PAR1 to PAR4), preserving user configurations, motor parameters, and fieldbus node addresses during complete power removal.

When configured as part of a Servo PLC system, application program routines are debugged and loaded using Drive PLC Developer Studio (DDS). During module replacement, parameter sets can be extracted from the active board or backed-up parameter files and restored directly to the new 9324MP.VB.61 card, eliminating the need to manually recalibrate control loops or set motor thresholds.

Communication and System Integration

Network integration for the Lenze 9324MP.VB.61 board is provided through an integrated CAN system bus operating at communication speeds up to 500 kbit/s. This bus facilitates high-speed multi-axis drive synchronization and parameter transfer across linked 9300 series controllers without requiring external gateway hardware.

To interface with higher-level industrial networks, the control board is equipped with a 33-pin Automation Interface (AIF) slot. This header accommodates various optional plug-in fieldbus modules, including PROFIBUS-DP (EMF2133IB), CANopen (EMF2178IB), and LECOM RS-232/485 (EMF2102IB) communication adapters.

Diagnostics and Status Indication

Operational status and error messages are displayed via two front-panel LED indicators alongside software-accessible status flags and a non-volatile TRIP buffer fault history. Real-time diagnostic evaluation can also be conducted using the GDC software oscilloscope or the EMZ9371BC keypad error display.

Status LED Indicators

LEDColor/StatusMeaning
Ready (Green LED)Green - Solid / FlashingContinuous green indicates normal operational state with controller enable. Blinking green indicates drive is ready for operation but controller inhibit (CINH) is active.
Fault (Red LED)Red - Solid / FlashingContinuous red indicates active TRIP condition or fault. Blinking red indicates active warning message.

Replacement and Spare Part Considerations

Before replacing a failing Lenze 9324MP.VB.61 board, confirm that the power section rated capacity matches the 3.0 kW 9324 specification. Prior to removing the old board, extract the saved parameter sets (PAR1 to PAR4) using GDC software or an EMZ9371BC operating keypad.

When swapping the unit, safely remove any installed AIF communication module, disconnect the 24V DC control supply, terminal connectors, and the 9-pin Sub-D motor feedback plug. Mount the replacement control board onto the power section, reinstall the AIF module, restore the saved parameter file, and confirm that proper 120-ohm termination resistors are installed on the CAN system bus lines before restoring line power.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit or earth fault on output power terminals.Short circuit in motor cable, phase-to-ground short, motor winding defect.Check motor wiring and motor insulation resistance. Verify output current rating.
OC5Overload During AccelerationDrive current limit exceeded during acceleration or steady operation.Mechanical load too high, jam in motor mechanism, acceleration time setting too short.Check drive mechanics for jamming; increase acceleration ramp time; check motor size.
OUOvervoltage DC BusDC bus voltage exceeded upper limit threshold.Excessive regenerative energy during braking, deceleration ramp too short, missing brake resistor.Increase deceleration time; check external brake resistor and brake chopper configuration.
LUUndervoltage DC BusDC bus voltage dropped below operating threshold.Mains supply line voltage drop, phase failure, power disruption.Check AC mains supply voltage, line fuses, and main contractor.
OHHeatsink OvertemperaturePower section heatsink temperature exceeded maximum permissible limit.Cabinet cooling failure, fan defective, ambient temperature too high, dirty heatsink fins.Clean heatsink, ensure adequate cabinet ventilation, check internal cooling fan function.
OH4Motor OvertemperatureMotor thermal contact or PTC thermistor tripped.Motor thermal overload, continuous low-speed high-torque operation, motor cooling fan failure.Allow motor to cool down, reduce motor load, check forced ventilation fan on motor.
CE0Automation Interface Communication ErrorCommunication failure or timeout on the AIF slot module.Interrupted fieldbus cable, loose plug, module configuration mismatch, master offline.Check fieldbus cabling, module seating in AIF slot, master status, and bus termination.
CE1System Bus (CAN) Communication ErrorTime-out or transmission fault on system bus CAN interface.CAN bus cable broken, missing bus termination resistor, baud rate mismatch.Verify CAN bus wiring, ensure 120-ohm termination resistors are present at both line ends, check baud rate settings.
EEREEPROM Memory ErrorNon-volatile parameter memory read/write error on the control board.Corrupted parameter memory, supply failure during parameter save, defective EEPROM hardware.Reload factory default parameter set. If error persists, internal hardware fault on board - replace control board.
H05Internal Hardware FaultInternal hardware failure on the control board.Defective internal processor, analog conversion module, or board power supply.Internal hardware fault - board is not field-serviceable, replace control board.
Sd7Resolver / Encoder FaultLoss or corruption of feedback signal from position encoder/resolver.Encoder cable defect, connector disconnected, broken encoder wire, encoder hardware failure.Check encoder/resolver connection and cable shielding. Inspect feedback sensor.
NMAXMaximum Speed ExceededActual motor speed exceeded maximum speed threshold.Unstable speed loop tuning, overhauling load driving motor, feedback signal fault.Check speed controller parameters, drive load, and feedback wiring.
PR0PLC Program Runtime ErrorExecution fault in PLC application program on Servo PLC board.Division by zero, pointer error, execution stack overflow in user PLC code.Debug PLC application code using Drive PLC Developer Studio (DDS).

Frequently Asked Questions

How do I back up and transfer parameters to a replacement 9324MP.VB.61 control card?

Parameter sets (PAR1 to PAR4) stored in the onboard EEPROM can be saved to a PC using Lenze Global Drive Control (GDC) software or copied onto an EMZ9371BC keypad before restoring them to the replacement control board.

What do the Ready and Fault LEDs indicate on the 9324MP.VB.61 control board?

The green Ready LED stays solid green during normal enable operation and flashes when controller inhibit (CINH) is active. The red Fault LED stays solid during an active TRIP fault and flashes when a warning condition occurs.

Which expansion modules are compatible with the onboard AIF slot?

The 33-pin AIF slot accepts optional fieldbus modules including PROFIBUS-DP (EMF2133IB), CANopen (EMF2178IB), and LECOM RS-232/485 (EMF2102IB) communication adapters.

What should I do if the control board reports fault code H05 or EER?

Fault code H05 indicates an unserviceable internal hardware fault, while EER indicates non-volatile parameter memory corruption. If restoring factory default parameters does not clear the EER fault, the board has suffered internal hardware damage and must be replaced.

What motor feedback devices connect to the 9324MP.VB.61 card?

The board features a dedicated 9-pin Sub-D connector designed for motor feedback signals from resolvers or encoders used in closed-loop positioning and speed control.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.