Lenze E70ACPSE0604S i700 Power Supply Module 60A

Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze E70ACPSE0604S is a central power supply module designed for the Lenze i700 Cabinet multi-axis drive system. Operating on a three-phase AC mains supply from 342 V AC to 528 V AC at 45 to 65 Hz, this unit provides a regulated 565 V DC output to feed adjacent single-axis and double-axis drive modules. Delivering a continuous DC output current of 60 A and a nominal power rating of 41.5 kW, it utilizes an integrated direct-fit DC busbar bridge system to minimize cabinet space and wiring complexity. To accommodate heavy acceleration and dynamic load pulses in high-density motion control panels, the unit supports a peak output current of 120 A for up to 3 seconds, and includes an integrated brake chopper transistor for connecting an external dynamic braking resistor.
System communication and parameter management are established through dual RJ45 EtherCAT interfaces operating at 100 Mbit/s in a line topology. Engineering and setup are supported using Lenze EASY Starter commissioning software or CODESYS-based Lenze PLC Designer tools, while control electronics require an external 24 V DC auxiliary power source. When exchanging a module in an existing system, the EtherCAT master automatically restores all operating parameters directly to the replacement unit over the network, eliminating the need for manual re-commissioning or external parameter backup tools. Maintenance teams sourcing a spare unit can rely on ABC Industrial Parts to supply reliable replacement hardware to keep downtime to a minimum.
Real-time diagnostic capabilities are accessible via the EtherCAT master online registers, internal non-volatile fault logs, and front-facing LED indicators. The RDY status LED indicates DC bus pre-charge and operational readiness, ERR signals faults and warnings, and L/A IN and L/A OUT display network port link and traffic states. Critical hardware conditions, such as continuous fast red blinking of the ERR LED on startup or unresolvable internal component faults, indicate internal board-level failure that cannot be serviced on-site. In these cases, installing a replacement module or utilizing repair services through ABC Industrial Parts offers a fast path to returning the machine to full production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | E70ACPSE0604S |
| Model / Type | i700 Power Supply Module 60A |
| Product Family | i700 Cabinet |
| Component Type | Power Supply Module |
| Supply Voltage Range | 342 - 528 V AC (3-phase) |
| Mains Frequency Range | 45 - 65 Hz |
| Control Supply Voltage | 24 V DC |
| Nominal DC Bus Output Voltage | 565 V DC |
| Rated Input Current | 60 A |
| Continuous DC Output Current | 60 A |
| Peak DC Output Current | 120 A (3 seconds) |
| Rated Output Power | 41.5 kW |
| Integrated Brake Chopper | Yes |
| System Bus Protocol | EtherCAT |
| Ethernet Interfaces | 2x RJ45 (100 Mbit/s) |
Programming and Configuration
Configuration and system engineering for the Lenze E70ACPSE0604S power module are conducted using Lenze EASY Starter software or Lenze PLC Designer for CODESYS-based motion controllers. The module interfaces with the central control platform via EtherCAT, enabling full visibility of system status, operational parameters, and fault logs.
During module replacement, manual parameter transferring is not required when the drive system is managed by an EtherCAT master controller. Upon detection of a replacement E70ACPSE0604S unit on the bus, the EtherCAT master automatically reloads the correct parameter sets to the device over the network, bringing the spare unit into operational status quickly.
Communication and System Integration
The E70ACPSE0604S features dual RJ45 100 Mbit/s Ethernet ports configured for EtherCAT communications. This dual-port architecture enables direct line-topology cabling from the central controller across the adjacent single and double axis drive modules within the i700 multi-axis line-up.
In addition to command and status data, the integrated fieldbus system supports direct DC busbar bridge coupling between the power module and drive axes. This reduces cabinet wiring, prevents layout errors, and maintains consistent high-density spacing within automated production machinery.
Diagnostics and Status Indication
System diagnosis is supported through multi-level indicators and software tools. Real-time condition checking can be executed via the Lenze EASY Starter diagnostic monitor, online registers inside the EtherCAT master controller, or by reading the non-volatile internal fault log stored in the module.
Front panel status LED indicators provide immediate feedback on DC bus pre-charging, operation readiness, active errors or warnings, and EtherCAT port link and activity states.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| RDY | Green - Solid / Flashing / Off | Green = Ready for operation / DC bus charged; Flashing Green = Pre-charge / Booting; Off = No control supply voltage |
| ERR | Red - Solid / Flashing / Off | Red Solid = Active fault present; Red Flashing = Warning condition; Off = No fault active; Continuous fast red blink on power-up = Internal hardware failure |
| L/A IN | Green - Solid / Flashing | Green = EtherCAT Input link established; Flashing Green = Data traffic active |
| L/A OUT | Green - Solid / Flashing | Green = EtherCAT Output link established; Flashing Green = Data traffic active |
Replacement and Spare Part Considerations
When replacing a failed E70ACPSE0604S power module, verify that the incoming 3-phase mains voltage matches the specified operating range of 342 V AC to 528 V AC and that the auxiliary 24 V DC supply delivers between 19.2 V DC and 28.8 V DC under load. Inspect the physical DC busbar connectors for signs of thermal stress, contamination, or wear prior to mounting the spare module.
Because the module utilizes automated parameter restoration via EtherCAT, manual transfer of parameter files is usually unnecessary when managed by a configured EtherCAT master. Ensure that the EtherCAT IN and OUT network cables are attached to the correct RJ45 ports to re-establish line-topology communications without bus interruptions.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| 0x2310 | Earth fault / Short circuit | Ground fault or short circuit detected on the output or power stage. | Short circuit in DC bus wiring, defective brake resistor, or internal power module defect. | Check DC bus wiring and brake resistor insulation. If fault persists with external connections removed, return unit for repair. |
| 0x2320 | DC bus overcurrent | Excessive current flow detected in the DC bus output circuit. | Short circuit across DC bus, excessive load pulse from axis drives, or defective power transistor. | Verify connected drive axes total current draw. Check DC bus bar insulation. If fault occurs instantly without load, return unit for repair. |
| 0x3130 | Mains phase failure | One or more input mains phases (L1, L2, L3) are missing or severely unbalanced. | Blown input line fuse, tripped circuit breaker, loose supply wiring, or high mains imbalance. | Check line supply voltages at L1, L2, L3 terminals under load. Inspect mains fuses and power contactors. |
| 0x3210 | DC bus overvoltage | DC bus voltage exceeded upper threshold limit. | High regenerative braking energy from axis motors, defective or disconnected brake resistor, or brake chopper circuit failure. | Check external brake resistor resistance and wiring. Verify brake chopper configuration settings. |
| 0x3220 | DC bus undervoltage | DC bus voltage dropped below minimum operating limit. | Mains input voltage too low, temporary mains voltage interruption, overload on DC bus, or internal pre-charge circuit fault. | Check line supply voltage levels. Check line contactors and input fuses. |
| 0x4210 | Heatsink overtemperature | Power section heatsink temperature exceeded maximum allowable limit. | Inadequate control cabinet ventilation, clogged cooling fans, ambient temperature too high, or continuous overload operation. | Clean heat sink cooling fins, verify cabinet fan operation and airflow, lower ambient temperature or reduce continuous load. |
| 0x5112 | 24V supply voltage error | Control electronics 24 V DC supply voltage is out of tolerance. | 24 V DC supply unit overloaded, supply voltage drop on long cabling, or internal 24V bus failure. | Check 24 V DC supply at terminals under load. Ensure voltage is within 19.2 V to 28.8 V DC. |
| 0x6100 | Internal hardware failure | Internal micro-controller or power board hardware error detected during diagnostic self-test. | Damaged internal component, corrupted EEPROM/flash memory, or control board defect. | Perform power cycle on 24V supply. If error remains, return unit for repair or replacement. |
| 0x7110 | Brake chopper short circuit / overcurrent | Overcurrent or short circuit detected in the internal brake chopper circuit. | Short circuit in external brake resistor or wiring, brake resistor resistance value too low, or defective internal brake chopper transistor. | Disconnect brake resistor and measure resistance. Ensure resistance matches specified minimum value. If resistor is okay, return unit for repair. |
| 0x7180 | Brake resistor I2t overload | Calculated thermal load on the brake resistor exceeded maximum rating. | Excessive braking duty cycle, brake resistor sized too small for deceleration energy. | Increase machine deceleration ramp time, or install a brake resistor with higher continuous power rating. |
Frequently Asked Questions
How are parameters reloaded when replacing a Lenze E70ACPSE0604S module?
When managed by an EtherCAT master controller, parameters are automatically downloaded to the replacement E70ACPSE0604S power module over the network upon device startup, restoring configuration without manual intervention.
What line supply voltage is required for the Lenze E70ACPSE0604S?
The module requires a 3-phase AC supply ranging from 342 V AC to 528 V AC at 45 to 65 Hz. It also requires a separate 24 V DC auxiliary supply for control electronics.
What does a continuous fast blinking red ERR LED indicate on startup?
A continuous fast blinking red ERR light during power-up signals an internal hardware failure or microcontroller fault (such as error 0x6100). If power cycling the 24 V DC supply does not clear the condition, the module requires repair or replacement.
Does the E70ACPSE0604S include dynamic braking capabilities?
Yes, the module includes an integrated brake chopper transistor. An external braking resistor can be connected to manage regenerative energy generated during motor deceleration.
Which software tools support diagnostics for this unit?
Diagnostics can be monitored using Lenze EASY Starter commissioning software, CODESYS-based Lenze PLC Designer, or through online diagnostic registers in the EtherCAT master controller.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.