Lenze EVS9323-ES 00402196 – 1.5kW 9300 Servo Inverter Drive
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze EVS9323-ES, identified by part number 00402196, is a 1.5 kW servo inverter drive within the Lenze 9300 Servo series designed for high-precision motion control applications. Operating on a 3-phase AC supply voltage from 320 V to 528 V AC (45 to 65 Hz) or a direct DC bus input from 460 V to 740 V DC, this drive provides a continuous output current of 3.9 A and a peak overload current of 5.9 A at an 8 kHz nominal switching frequency. It delivers an output frequency range of 0 to 480 Hz to drive AC servo motors in synchronized multi-axis positioning, web tension control, and dynamic conveyor applications across packaging, printing, textile, and material handling lines.
Interfacing with feedback and control devices is accomplished through dual onboard feedback connections: a Sub-D 9-pin connector X7 for 2-pole or multi-pole resolvers and a Sub-D 15-pin connector X8 for TTL or SinCos incremental encoders, along with an X9 encoder simulation output for master-slave coupling. Network integration includes an onboard CAN system bus interface on terminal X4 supporting transmission speeds up to 500 kbit/s, while an Automation Interface (AIF) slot accommodates optional fieldbus communication modules such as PROFIBUS-DP or LECOM, as well as the Keypad XT user interface module. Placing a spare EVS9323-ES into service requires transferring application parameter sets stored in internal non-volatile EEPROM—which holds up to four independent configurations—using Lenze Global Drive Control (GDC), EASY Starter software, or a Keypad XT module. ABC Industrial Parts offers expert support to assist with parameter backup extraction and transfer from faulty units.
Immediate operational status is displayed via three front-panel LEDs: a solid green READY LED indicating normal operation, a solid yellow WARNING LED signalling threshold warnings, and a solid or flashing red FAULT LED indicating active trip conditions. Diagnostic navigation is managed through parameter codes C0161 to C0170 and a time-stamped fault history buffer retaining the last eight error events accessible via GDC software or the Keypad XT module. Specific fault codes such as overcurrent (OC1, OC2, OC3, OC5), overvoltage (OU), undervoltage (LU), temperature limits (OH, OH3, OH4), or feedback loss (E1, E2) guide targeted physical checks on line power, braking resistors, cooling fans, and encoder cabling. For internal hardware failures such as micro-controller or power stage faults (H05 or H07), field service is not viable, making direct replacement or a tested exchange drive from ABC Industrial Parts the fastest route to restore production.
Technical Specifications
| Rated Power Output | 1.5 kW |
| Supply Voltage Range (AC) | 320 - 528 V AC |
| DC Bus Voltage Range | 460 - 740 V DC |
| Continuous Output Current | 3.9 A |
| Peak Output Current | 5.9 A |
| Nominal Switching Frequency | 8 kHz |
| Output Frequency Range | 0 - 480 Hz |
| Digital Inputs | 4 |
| Digital Outputs | 2 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
Programming and Configuration
Parameter setup and application management for the Lenze EVS9323-ES drive are conducted using Lenze Global Drive Control (GDC) or EASY Starter software. The drive relies on a flexible function block architecture that permits custom assignment of internal motion control functions, position loops, and speed profile routines. Operating parameter sets are retained inside integrated non-volatile EEPROM memory, which holds up to four independent parameter sets.
Field parameters can be saved, edited, or backed up directly using the optional plug-in Keypad XT module (EMZ9371BC) mounted on the front Automation Interface (AIF) slot. Keypad XT memory copy functions allow rapid transfer of full parameter files from one drive unit to another without a computer. When loading fresh configurations via software or keypad, executing parameter store routines via code C0002 ensures non-volatile retention.
Communication and System Integration
System integration is facilitated through the onboard CAN system bus interface on terminal X4, which supports baud rates up to 500 kbit/s for synchronized multi-axis master-slave operation and fast parameter interchange. Terminal X4 provides physical CAN transmission line connections that require proper 120-ohm bus termination at both line ends.
Modularity is expanded via the front Automation Interface (AIF) slot, which accepts dedicated communication adapters including PROFIBUS-DP modules (EMF2133IB / EMF2131IB) and LECOM modules (EMF2102IB / EMF2171IB). These communication boards allow the EVS9323-ES to interface with higher-level PLC system architectures, complemented by four onboard digital inputs, two digital outputs, two analog inputs, and two analog outputs.
Diagnostics and Status Indication
Real-time operational feedback is provided on the front interface by three status LEDs indicating readiness, warning conditions, and active fault trips. Parameter monitoring codes C0161 through C0170 expose internal runtime variables, actual motor speeds, DC bus voltages, and load levels.
Fault events are logged in an internal history buffer that stores up to eight past errors alongside time stamp indices, accessible via parameter codes C0183 and C0168 on the Keypad XT or inside the GDC diagnostic window.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| READY | Green - Solid | Drive ready for operation |
| FAULT | Red - Solid or Flashing | Drive fault trip active |
| WARNING | Yellow - Solid | Operating warning threshold reached |
Replacement and Spare Part Considerations
When swapping a damaged unit with a replacement Lenze EVS9323-ES, ensure exact hardware matching across part number 00402196. Crucially, plug-in fieldbus option cards (such as PROFIBUS or LECOM modules) must be unclipped from the front AIF slot of the original unit and transferred directly to the replacement unit.
Because new or spare drives do not ship pre-configured, downloading the machine's specific parameter file using Global Drive Control (GDC) software or transferring the EEPROM data set via a Keypad XT module is required prior to starting the motor. If direct parameter upload is not possible due to hardware failure, technical parameter extraction from donor boards or system backup archives should be utilized.
For modernizing machines containing legacy 9300 series drives, upgrade options include retrofitting to contemporary Lenze i700 or i950 series servo drives, which may require motor wiring and fieldbus network adjustment.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit / Overcurrent during Acceleration | Output current exceeds overcurrent threshold during acceleration ramp. | Short circuit in motor cable; ground fault; acceleration time set too short; motor underdimensioned. | Check motor and motor cable for short circuit or earth fault; increase acceleration time (C0012); check motor load. |
| OC2 | Short Circuit / Overcurrent during Deceleration | Output current exceeds overcurrent threshold during deceleration ramp. | Deceleration time set too short; short circuit in motor cable; brake chopper error. | Increase deceleration time (C0013); check motor cable insulation; check brake resistor. |
| OC3 | Overcurrent during Constant Operation | Output current exceeds threshold under constant load/speed conditions. | Sudden mechanical load surge; motor overload; short circuit. | Check mechanical drive system for blockage; inspect motor wiring; check drive rating. |
| OC5 | I x t Overload | Drive overload integrator limit reached (150% current over prolonged duration). | Continuous operation above rated current; mechanical overload; motor undersized. | Check drive loading profile; reduce mechanical load; verify motor dimensions. |
| OU | DC Bus Overvoltage | DC bus voltage exceeds maximum limit (> 770 V DC / 800 V DC). | Braking energy too high; braking resistor missing or defective; deceleration time too short; mains voltage too high. | Connect or check external braking resistor; increase deceleration time; check mains supply voltage. |
| LU | DC Bus Undervoltage | DC bus voltage dropped below minimum operating limit (< 430 V DC). | Mains supply failure; phase loss; input line voltage too low. | Check mains voltage supply; check fuses and power connections. |
| OH | Heatsink Overtemperature | Heatsink temperature exceeds 90 °C limit. | Ambient temperature too high (> 45 °C); cooling fan failure or blocked; heatsink dirty; insufficient mounting distance. | Clean heatsink fins; ensure adequate cabinet ventilation; replace cooling fan if failed. |
| OH3 | Motor Overtemperature | Motor temperature sensor (PTC or KTY) signals overtemperature. | Motor thermal overload; cooling fan on motor defective or stopped; sensor cable broken. | Allow motor to cool down; check motor loading; inspect PTC/KTY sensor connections on terminals X10. |
| OH4 | Heatsink Temperature Warning | Heatsink temperature exceeded 85 °C pre-warning threshold. | High ambient cabinet temperature; heavy duty cycle. | Improve enclosure cooling before hard trip OH occurs. |
| CE0 | CAN System Bus Fault | Communication failure or Bus-Off state on integrated system bus (X4). | CAN bus cable interrupted or shorted; missing bus termination resistor (120 Ohm); baud rate mismatch. | Inspect CAN wiring and shielding; verify 120 Ohm termination resistors at physical ends of CAN line; check baud rate settings. |
| CE1 | AIF Module Communication Error | Communication fault between drive and plug-in automation module in AIF slot. | Fieldbus module loose or improperly seated; fieldbus network cable disconnected; master offline. | Check module seating; check fieldbus cable and master controller status. |
| E1 | Incremental Encoder Fault | Signal error or broken wire on incremental encoder input (X8). | Encoder cable disconnected or broken; encoder supply voltage missing; hardware fault on encoder. | Check encoder cable and plug connections; verify encoder power supply; replace encoder if necessary. |
| E2 | Resolver Fault | Resolver feedback signal loss or track fault on resolver connector (X7). | Resolver cable broken or loose; resolver excitation coil shorted or open. | Inspect resolver cable shield and pin connections on X7; measure resolver coil resistance; check resolver hardware. |
| H05 | Internal Hardware Fault | Internal micro-controller, memory, or board error detected during self-test. | EEPROM checksum failure; control board hardware malfunction. | Internal hardware fault — power cycle drive. If problem persists, return unit for factory repair or replacement. |
| H07 | Internal Power Stage Fault | Hardware fault or gate driver failure inside power section. | Power transistor module (IGBT) damaged; internal supply failure. | Internal hardware fault — cannot be serviced in the field. Return drive unit for repair/replacement. |
| NMAX | Maximum Speed Exceeded | Motor speed feedback exceeded maximum allowable safety threshold. | Speed controller gain improper; external overhauling load; incorrect encoder pulse setting. | Check speed controller parameters; verify encoder resolution settings in C0425; check mechanical load. |
| PEr | Parameter Error | Inconsistent parameter configuration or checksum error in EEPROM. | Interrupted parameter download or power failure during parameter store. | Reload default parameter set (factory settings via C0002) and re-download application parameter set. |
Frequently Asked Questions
How do I back up and transfer parameters to a replacement Lenze EVS9323-ES drive?
Parameters can be transferred using Lenze Global Drive Control (GDC) or EASY Starter software via a PC connection. Alternatively, parameter sets stored in non-volatile EEPROM can be copied directly using a Keypad XT (EMZ9371BC) module attached to the front Automation Interface (AIF) slot.
What feedback devices are supported by the EVS9323-ES drive?
The drive features integrated dual feedback inputs supporting standard 2-pole or multi-pole resolvers via Sub-D 9-pin connector X7 and TTL or SinCos incremental encoders via Sub-D 15-pin connector X8.
How can fieldbus protocols like PROFIBUS or LECOM be connected to this drive?
Communication expansion is achieved via the plug-in Automation Interface (AIF) slot on the front panel. Optional fieldbus modules, such as PROFIBUS (EMF2133IB / EMF2131IB) or LECOM (EMF2102IB / EMF2171IB), snap directly into the slot without requiring main board modifications.
What does fault code H05 or H07 indicate on the Lenze 9300 Servo drive?
Fault code H05 indicates an internal microcontroller or memory hardware error (such as EEPROM checksum failure), while H07 indicates an internal power stage hardware fault. These hardware errors are not field-serviceable and require a power cycle or unit replacement.
What causes a CE0 fault and how is it resolved?
A CE0 code signifies a CAN system bus fault on terminal X4. This is caused by interrupted wiring, bus-off conditions, baud rate mismatches, or missing 120-ohm termination resistors at the physical ends of the CAN line. Resolving it requires inspecting CAN cabling, checking settings, and verifying termination resistors.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.



