Lenze 13015367 E82EV152_4C 8200 Vector Frequency Inverter

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 Vector | Series: 8200 Vector

The Lenze 13015367 E82EV152_4C is a 1.5 kW (2 HP) frequency inverter from the Lenze 8200 Vector drive family, engineered for variable speed regulation and direct torque control of standard three-phase AC asynchronous motors. Operating on a three-phase mains supply ranging from 320 V to 528 V AC at 45 to 65 Hz, this compact unit delivers a rated output current of 3.9 A at 400 V or 3.3 A at 480 V. It features selectable motor control methods, including linear V/f, quadratic V/f, and sensorless vector control (VFC), providing precise speed stability across an output frequency range of 0 to 480 Hz. Designed with an IP20 enclosure rating and an integrated cooling heatsink for panel mounting, the drive withstands demanding duty cycles with a 150% overload rating (5.9 A) for up to 60 seconds in applications such as conveyor systems, industrial pumps, ventilation fans, and packaging machinery.

Integrating a replacement drive into existing equipment requires verifying both physical interfaces and parameter settings. The E82EV152_4C base unit features modular expansion slots that accept plug-in function modules for fieldbus communication, including the E82ZAFCC CANopen module and the E82ZAFPC010 PROFIBUS DP module, as well as interfaces for INTERBUS, DeviceNet, and AS-Interface. Commissioning a spare unit is rarely a plug-and-run operation, as parameter configurations stored in the internal non-volatile EEPROM—which holds up to four complete parameter sets—must match the machine application. Parameter cloning can be completed using the optional XT Keypad E82ZBC operator module or transferred via an E82ZWL001 PC diagnosis adapter using Lenze Global Drive Control (GDC) or EASY Starter software. ABC Industrial Parts can support maintenance teams with parameter cloning, configuration transfer, and spare unit preparation to ensure proper alignment prior to system installation.

Diagnostic monitoring on the unit relies on front-panel LED indicators alongside internal software parameters. The drive features a green Ready LED that indicates power supply, initialization, or active output status, and a red Fault LED that signals active warnings or a TRIP state. Detailed fault logs and operating parameters C0003 and C0161–C0163 can be evaluated via keypad or GDC software to identify faults such as overcurrent (OC1, OC2, OC5), heatsink overheating (OH), or DC bus overvoltage (OU). When the red LED remains lit continuously or hardware codes such as EE0, EEr, or H05 appear, an internal control board failure is present. Internal electronic faults are not field-serviceable, making drive repair or a tested exchange unit from ABC Industrial Parts the recommended solution to minimize production downtime.

Technical Specifications

ManufacturerLenze
Part Number13015367
Model / TypeE82EV152_4C
Product Family8200 Vector
Component TypeFrequency Inverter
Rated Power (kW)1.5 kW
Rated Power (HP)2 HP
Supply Voltage Range320 - 528 V AC
Supply Frequency Range45 - 65 Hz
Rated Output Current (400V)3.9 A
Rated Output Current (480V)3.3 A
Maximum Output Current (60s Overload)5.9 A (150%)
Output Frequency Range0 - 480 Hz
Switching Frequency8 kHz (adjustable 2 - 16 kHz)
Control MethodsV/f linear, V/f quadratic, Sensorless Vector Control (VFC)
Protection RatingIP20
Mounting TypePanel Mount

Programming and Configuration

Programming and commissioning the Lenze 13015367 E82EV152_4C frequency inverter can be executed through software interfaces or plug-in hardware modules. Using the Lenze Global Drive Control (GDC) or EASY Starter engineering tools alongside an E82ZWL001 PC diagnosis adapter, engineers gain complete access to parameter structures, live diagnostic values, and fault history logs.

The internal EEPROM memory stores up to four complete parameter sets. For field servicing without a laptop, the optional XT Keypad E82ZBC operator module allows rapid parameter copying and cloning directly between inverter units. Resetting parameters to factory defaults via parameter C0002 provides a clean baseline when clearing corrupted setups or reconfiguring a unit for a new motor.

Communication and System Integration

The modular architecture of the Lenze 8200 Vector series simplifies fieldbus integration into higher-level automation networks. The base unit includes dedicated slots designed to accept plug-in communication modules according to system requirements.

Supported interface modules include the E82ZAFCC for CANopen and the E82ZAFPC010 for PROFIBUS DP, as well as modules for INTERBUS, DeviceNet, and AS-Interface. Loose module seating or bus cable interruptions will register on the drive under fault code CE0, requiring mechanical seating checks during commissioning.

Diagnostics and Status Indication

Operational status and fault conditions on the E82EV152_4C are diagnosed through status LEDs and onboard software parameters. Drive parameters C0003 and C0161 through C0163 record active operating states and historical trip details, accessible via keypad or GDC software.

Two status LEDs on the front panel provide visual operational state feedback, as summarized below.

Status LED Indicators

LEDColor/StatusMeaning
Ready LED (Green)Green - Off / Flashing / SolidOff: Drive off / internal power supply missing; Flashing: Drive inhibited or initializing; On: Drive operational / output enabled
Fault LED (Red)Red - Off / Flashing / SolidOff: Normal operation; Flashing: Warning condition active; On: Active fault / TRIP state present. Continuous light indicates hardware failure.

Replacement and Spare Part Considerations

When replacing a failed Lenze 13015367 E82EV152_4C inverter, maintenance staff must verify both physical hardware options and parameter configurations. Installed communication modules—such as CANopen or PROFIBUS function cards—must be transferred to the replacement unit slot and checked for proper mechanical seating.

Replacement inverters are supplied with factory baseline settings. Before running the drive, parameters must be loaded from a backup file via GDC/EASY Starter software or cloned using the XT Keypad E82ZBC operator module to ensure acceleration, deceleration, current limits, and motor protection profiles match the machine requirements.

If the existing drive exhibits hardware codes such as EE0, EEr, or H05, or shows a solid red Fault LED that cannot be cleared by power cycling or reloading parameter defaults, internal board failure has occurred. Servicing internal electronics requires professional repair or replacement with a tested spare unit.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short CircuitShort circuit at frequency inverter output terminals U, V, WShort circuit in motor cable, short circuit in motor windings, acceleration time set too shortCheck motor cable and motor insulation, check acceleration time parameter C0012
OC2Earth FaultEarth fault / ground fault at output terminals U, V, WEarth fault in motor cable or motor, excessive cable capacitanceCheck motor and motor cable for earth faults, check motor cable length limits
OC5I x t OverloadContinuous overload / Ixt thermal monitoring threshold exceededDrive loaded above rated output current for an extended period, motor mechanically blockedCheck drive dimensioning, verify motor load and mechanics, reduce load current
OHHeatsink OverheatingHeatsink temperature exceeds threshold (> 90 °C)Inadequate cooling, fan failure or blocked, ambient temperature too high, dirty heatsinkClean heatsink, verify fan function and cooling airflow, reduce ambient temperature or load
OH4Motor Temperature OverheatingThermal sensor / PTC input triggeredMotor thermal contact or PTC sensor opened due to motor overheatingAllow motor to cool down, check motor load and cooling fan function
OUOvervoltage DC BusDC bus voltage exceeds maximum limit (> 800 V DC for 400V class)Braking energy regenerated from motor too high, deceleration time set too short, brake chopper/resistor missing or defectiveIncrease deceleration time parameter C0013, install brake module/resistor, check main supply voltage
LUUndervoltage DC BusDC bus voltage fell below minimum limit (< 430 V DC for 400V class)Mains supply voltage too low, main phase missing, line fuse blown, power supply dipCheck line supply voltage, check supply fuses and wiring connections
LP1Phase FailureMains supply phase fault detectedFailure of one supply phase, severe mains voltage unbalanceCheck mains voltage connection on terminals L1, L2, L3 and supply fuses
EE0EEPROM Data FaultInternal EEPROM memory checksum error or corrupted configuration dataPower failure during parameter write operation, defective internal EEPROM memory chipReload factory default parameters (parameter C0002). If error persists, internal board hardware fault — return unit for repair or replace inverter.
EErEEPROM Read ErrorFailure accessing non-volatile parameter memoryInternal hardware failure on control boardInternal hardware failure — return unit for repair or replace inverter.
CE0Communication Fault Module SlotCommunication error between inverter base unit and plug-in function moduleFunction module loose or defective, fieldbus bus interruptionCheck mechanical seating of function module, check fieldbus cable connection
PErParameter ErrorInconsistent parameter configuration or parameter set upload errorIncompatible parameter configuration uploaded or transfer interruptedRestore factory default parameters or download valid project file using GDC software
H05Internal FaultInternal control board hardware or processor errorInternal electronic failureInternal hardware fault — return unit for repair or replace inverter.

Frequently Asked Questions

How are parameters transferred to a replacement Lenze 13015367 inverter?

Parameter sets can be cloned directly between drives using the plug-in XT Keypad E82ZBC operator module or loaded from project backups using Lenze Global Drive Control (GDC) or EASY Starter software via an E82ZWL001 PC diagnosis adapter.

Which fieldbus modules can be used with the Lenze E82EV152_4C drive?

The inverter supports plug-in function modules including the E82ZAFCC for CANopen and E82ZAFPC010 for PROFIBUS DP, along with modules for INTERBUS, DeviceNet, and AS-Interface.

What does a solid red Fault LED indicate on the inverter?

A solid red Fault LED indicates an active TRIP state or an unrecoverable internal hardware failure on the control board.

What action should be taken if fault code OC1 or OC2 appears?

Fault code OC1 signals an output short circuit, while OC2 indicates an earth fault. Inspect motor wiring, motor windings, and ground insulation, and verify that acceleration time parameter C0012 is properly configured.

Can hardware errors like EE0, EEr, or H05 be cleared in the field?

Error EE0 can sometimes be cleared by reloading default parameters via C0002. However, if EE0 persists or codes EEr and H05 appear, an internal hardware failure is present that requires unit repair or replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.