Lenze 13400419 E94ASHE0244 9400 HighLine Servo Drive

New 
On request
Refurbished   
6 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9400 HighLine

The Lenze 13400419 (model E94ASHE0244) is an 11 kW servo drive from the Lenze 9400 HighLine product family, engineered for precise dynamic motion control and axis synchronization in industrial automation systems. Operating from a three-phase mains supply voltage range of 320 to 528 V AC (3 x 400/480 V AC nominal), it delivers up to 24.5 A continuous output current with an output frequency range of 0 to 599 Hz. This panel-mount drive controls synchronous servo motors such as the Lenze MCA and MCS series, asynchronous AC motors with encoder feedback, and open-loop V/f configurations. It integrates advanced motion functionality onboard, handling point-to-point positioning, electronic gearboxes, and complex electronic cam profiling to minimize central PLC computing load.

System connectivity and control integration are facilitated by onboard input and output interfaces alongside flexible expansion options. The unit provides 8 digital inputs, 4 digital outputs, 2 analog inputs (±10 V), and 2 analog outputs (±10 V), along with a universal X8 multi-encoder interface supporting Resolver, SinCos, Hiperface, EnDat 2.1/2.2, and SSI feedback devices. Distributed networking is managed through an integrated CANopen system bus operating up to 1 Mbit/s, while Option Slot 2 supports communication cards like the E94AYCER PROFINET or E94AYCEC EtherCAT modules. Commissioning a spare drive relies on pluggable MM200 or MM300 parameter memory modules, which hold all parameter sets, motor profiles, and application code. Swapping this memory card into a replacement drive enables fast, hardware-based unit replacement without a laptop. ABC Industrial Parts can assist maintenance teams with donor parameter transfer and drive preparation.

Drive operational status and diagnostic messages are indicated through front-panel LED indicators, an optional pluggable E94AZKAE keypad, or software diagnostic buffers in Lenze Engineer and EASY Starter. When troubleshooting abnormal drive behavior, first-line verification should cover mains supply voltage, DC bus level, motor cable insulation, encoder shield grounding at connector X8, and safety circuit interlocks. Fault conditions such as a solid red DRV-ERR LED across power resets or immediate overcurrent trips with no motor connected point to internal power stage or sensing circuit failures that are not field-serviceable. In these cases, ABC Industrial Parts offers comprehensive repair services and fully tested exchange drives to restore operating conditions quickly.

Technical Specifications

ManufacturerLenze
Part Number13400419
Model / TypeE94ASHE0244
Product Family9400 HighLine
Component TypeServo Drive
Rated Power11 kW
Supply Voltage3 x 400/480 V AC
Supply Voltage Range320 - 528 V AC
Continuous Output Current24.5 A
Output Voltage0 - 3 x Mains
Output Frequency Range0 - 599 Hz
Switching Frequency4 kHz
Digital Inputs8
Digital Outputs4
Analog Inputs2 (±10 V)
Analog Outputs2 (±10 V)
Onboard FieldbusCANopen / System Bus (1 Mbit/s)
Mounting TypePanel Mount (E Type)

Programming and Configuration

The Lenze 13400419 E94ASHE0244 drive features advanced internal motion control logic configured through Lenze Engineer or EASY Starter software packages. The drive firmware supports point-to-point positioning routines, electronic gear ratios, and complex electronic cam profiling directly onboard, reducing the burden on main PLC CPUs in high-speed packaging, gantry, and converting machinery.

All parameter sets, motor calibration data, and application programs reside on removable MM200 or MM300 memory modules. When replacing a unit in the field, moving the existing memory module into the replacement servo drive transfers the complete configuration without requiring a computer or software connection.

Communication and System Integration

System integration is supported natively via an onboard CANopen system bus capable of transmission speeds up to 1 Mbit/s. This allows tight multi-axis synchronization and rapid exchange of control registers across automated networks.

For higher-level network integration, Option Slot 2 accepts modular communication cards including the E94AYCER PROFINET and E94AYCEC EtherCAT modules, as well as PROFIBUS-DP and EtherNet/IP options. Option Slot 1 is dedicated to functional safety modules, accommodating Safety01 through Safety03 modules for safe motion supervision.

Diagnostics and Status Indication

Real-time diagnostic capability includes status LEDs on the front panel, an optional E94AZKAE pluggable keypad unit displaying plain-text error messages, diagnostic buffer logs accessible via Lenze Engineer and EASY Starter software, and CANopen diagnostic register inspection.

The four dedicated LEDs provide immediate status breakdown for both CANopen network activity and internal drive controller states, allowing technicians to isolate bus failures from internal hardware trips.

Status LED Indicators

LEDColor/StatusMeaning
CAN-RUNGreen - Solid / Blinking / OffCANopen bus state indicator. Solid = Operational; Blinking = Pre-operational; Off = Bus off / Stopped.
CAN-ERRRed - Solid / FlashingCANopen communication error indicator. Solid or flashing indicates bus warning or bus off condition.
DRV-READYGreen - Solid / BlinkingDrive operational status. Solid = Controller enabled and active; Blinking = Drive ready, controller inhibited.
DRV-ERRRed - SolidFault indicator. Solid red indicates active error/trip condition. Persistent red across power cycles indicates internal board failure.

Replacement and Spare Part Considerations

When swapping a Lenze 13400419 E94ASHE0244 drive, ensure the replacement unit matches the required power rating (11 kW) and physical mounting frame (Panel Mount E Type). Check that option cards inserted in Option Slot 1 (Safety modules) and Option Slot 2 (Fieldbus modules such as E94AYCER PROFINET or E94AYCEC EtherCAT) are transferred to the replacement unit in identical configurations.

The MM200 or MM300 parameter memory module allows zero-tool parameter transfer during unit replacement. Carefully transfer the card from the original drive to the spare drive before powering up. Verify that motor feedback settings on multi-encoder port X8 match connected synchronous motors (such as Lenze MCA or MCS series) or asynchronous motor configurations.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
0x00110001OC1 Short Circuit / OvercurrentInstantaneous current threshold exceeded on motor output phases U, V, W.Short circuit in motor winding or power cable, ground short, acceleration rate too steep.Check motor cable and insulation resistance, verify motor parameters, increase acceleration time. If trip occurs instantly without motor connected, internal IGBT power stage failure detected — return unit for repair.
0x00120001Earth FaultGround fault current detected on output channels.Insulation breakdown in motor winding, pinched output cable, excessive earth leakage current.Check output cable and motor with insulation tester. If cable and motor pass insulation tests, internal current sensing circuit fault requires repair.
0x00210001OU Overvoltage DC BusDC bus link voltage exceeded upper voltage shutdown limit.Excessive regenerative energy during deceleration, brake chopper resistor open or defective, excessive supply line voltage.Check brake chopper resistor value and wiring, extend deceleration ramp, verify AC supply voltage.
0x00220001LU Undervoltage DC BusDC bus link voltage dropped below lower operation threshold.Mains supply line failure, blown line input fuse, line contactor opened under load.Check mains line voltage, inspect line fuses, check supply connection terminals.
0x00310001OH Heatsink OvertemperaturePower section heatsink temperature surpassed maximum safety limit.Cooling fan failed or blocked, cabinet ventilation inadequate, ambient temperature too high, clogged heatsink fins.Clean heatsink, verify cooling fan operation, check enclosure airflow and ambient conditions.
0x00320001Motor Overtemperature (I²t)Calculated thermal load on motor reached maximum trip limit.Continuous mechanical overload, motor undersized for duty cycle, mechanical binding.Verify load cycle and motor sizing, check for mechanical friction or jams.
0x00510001Encoder Fault (X8)Loss of signal or invalid position feedback on multi-encoder interface X8.Loose feedback cable, defective encoder, incorrect encoder power supply setting.Check feedback cable shield and connector seating, inspect encoder, verify encoder configuration parameters.
0x00710001Safety Module FaultChannel discrepancy or internal fault detected by Option Slot 1 safety module.Safety channel timing mismatch, defective safety wiring, internal safety module hardware error.Check dual-channel safety wiring and relay timing. If safety inputs match and error persists, safety module internal hardware fault — replace safety module or return drive for repair.

Frequently Asked Questions

Which programming software is required to configure the Lenze E94ASHE0244 servo drive?

The drive is commissioned and programmed using Lenze Engineer or EASY Starter software tools. Alternatively, basic parameter changes and status checks can be performed using the pluggable E94AZKAE keypad unit.

How do I transfer drive parameters when replacing a failed 13400419 drive?

All parameter data, motor profiles, and application code are stored on the pluggable MM200 or MM300 memory module. Removing the module from the original drive and inserting it into the replacement drive transfers all configuration data without needing software or a laptop.

What encoder types are supported on the X8 feedback interface?

The universal X8 multi-encoder interface supports Resolver, SinCos, Hiperface, EnDat 2.1/2.2, and SSI feedback encoder types.

What optional fieldbus communication modules can be added to Option Slot 2?

Option Slot 2 supports optional communication cards including the E94AYCER PROFINET module and the E94AYCEC EtherCAT module, as well as PROFIBUS-DP and EtherNet/IP interface modules.

What does a persistent red DRV-ERR LED indicate on the Lenze 13400419 drive?

A solid red DRV-ERR LED indicates an active trip condition. If the red light remains solid across power cycles or trips immediately upon power-up without a connected motor, an internal hardware failure on the power or sensing board has occurred, requiring drive repair or replacement.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.