Lenze 13431044 EVS9327-ES 9300 Servo Inverter Module
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13431044 EVS9327-ES is an 11 kW servo inverter within the Lenze 9300 Servo series, engineered for dynamic speed and torque regulation of synchronous and asynchronous motors. As a dedicated -ES design variant, this drive operates on a 3-phase mains supply from 320 V AC to 528 V AC with a nominal rating of 400/480 V AC. It delivers a continuous rated output current of 23.5 A and a maximum peak current of 35.3 A, supporting heavy overload demands up to 150% continuous output current for 60 seconds during acceleration cycles. Built around field-oriented vector control and an 8 kHz switching frequency, the drive provides dynamic motion performance across packaging, textile, printing, converting, and automotive production environments.
For integration and control, the EVS9327-ES includes an onboard CAN system bus interface alongside a modular Automation Interface (AIF) slot that accepts fieldbus cards such as the EMF2133IB PROFIBUS DP and EMF2173IB DeviceNet communication modules. Physical interfaces include five digital inputs, four digital outputs, two analog inputs, two analog outputs, a resolver feedback input on connector X7, an encoder input on connector X8, and an encoder simulation output for master-slave synchronization. Commissioning a spare drive requires transferring operational parameters, as the unit relies on non-volatile EEPROM memory holding up to four distinct parameter sets. Parameter transfer can be completed using the pluggable EMF2102IB XT keypad module or Lenze Global Drive Control (GDC) software to restore original drive parameters with support from ABC Industrial Parts.
Drive status and operating conditions are indicated via three multi-color LED indicators representing operational status, warning levels, and active fault states. System diagnostics can be conducted through the TRIP memory buffer in parameter C0161 or C0168, accessible via the EMF2102IB keypad display or the GDC software oscilloscope function. First-line troubleshooting involves checking input mains power supply across 320 V AC to 528 V AC, verifying power wiring for phase-to-phase or phase-to-earth shorts, inspecting resolver cabling on connector X7, and testing 120-ohm CAN bus line terminations. If internal microcontroller or control board failures such as fault code H05 occur, hardware cannot be repaired in the field, making a tested replacement unit or repair service through ABC Industrial Parts the recommended solution.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13431044 |
| Model/Type | EVS9327-ES |
| Component Type | Servo Inverter |
| Product Family | 9300 Servo |
| Rated Power | 11 kW |
| Nominal Supply Voltage | 400 V AC |
| Supply Voltage Range | 320 - 528 V AC |
| Continuous Rated Output Current | 23.5 A |
| Maximum Output Current | 35.3 A |
| Switching Frequency | 8 kHz |
| Control Method | Field-oriented vector control / Servo control |
| Digital Inputs | 5 |
| Digital Outputs | 4 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
Programming and Configuration
The Lenze 13431044 EVS9327-ES servo inverter is configured using Lenze Global Drive Control (GDC) PC software or the optional pluggable EMF2102IB XT Keypad Operating Module. Parameter storage is handled inside non-volatile EEPROM memory capable of holding up to four complete parameter sets, allowing multi-product setups or operational profile switching without re-downloading complete drive configurations.
When transferring or adjusting parameters, the pluggable keypad module enables direct parameter backup and parameter set cloning across drives. Parameter history log inspection is accessible via codes C0161 and C0168. If a parameter set becomes corrupted during operational transfer, fault code PR signals the memory issue, which can be cleared by loading factory default settings through code C0002 before re-applying custom parameters.
Communication and System Integration
System communication on the EVS9327-ES relies on an integrated CAN system bus alongside a flexible Automation Interface (AIF) expansion slot. The onboard CAN bus allows direct multi-drive network integration and centralized control commands. Correct CAN operation requires 120-ohm termination resistors fitted at both ends of the CAN bus line to avoid telegram interruptions such as CE1 or CE2 communication faults.
The modular AIF slot connects the drive to higher-level automation fieldbuses via add-on modules, including the EMF2133IB PROFIBUS DP card and the EMF2173IB DeviceNet card, as well as INTERBUS and LECOM serial communication adapters. Discrete I/O handling is supported through five digital inputs, four digital outputs, two analog inputs, and two analog outputs, complemented by resolver input X7, encoder input X8, and an encoder simulation output.
Diagnostics and Status Indication
Operational state monitoring for the EVS9327-ES drive is displayed via three front panel status LEDs. Detailed diagnostic evaluation is performed by reading fault memory codes C0161 and C0168 through the EMF2102IB keypad module display or using the diagnostic monitor and live oscilloscope tool within Lenze Global Drive Control software.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Red LED | Red - Solid | Fault state (TRIP active). Drive is inhibited due to active fault condition. |
| Green LED | Green - Solid or Flashing | Operational state (Drive Ready / Running). Blinking indicates controller inhibit or phase operation. |
| Yellow LED | Yellow - Solid | Warning condition active or current limit reached. |
Replacement and Spare Part Considerations
When installing a replacement Lenze 13431044 EVS9327-ES module, confirm that the power specification of 11 kW and nominal supply rating of 400/480 V AC match the target machine's original configuration. Any optional communication card installed in the AIF slot, such as the EMF2133IB PROFIBUS DP or EMF2173IB DeviceNet module, must be transferred to the replacement drive to preserve network integration.
A replacement unit requires parameter loading before it can operate. The parameter set should be transferred from the original unit or downloaded from a saved configuration file using Lenze Global Drive Control (GDC) software or the EMF2102IB keypad module. For long-term system modernization, Lenze designates the i950 Servo Inverter as the recommended successor series.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit / Earth Fault / Overcurrent | Short circuit or earth fault on motor output, or excessive current during acceleration. | Short circuit in motor cable or winding, ground fault, acceleration ramp too short. | Check motor and power wiring for phase-to-phase and phase-to-earth shorts. Increase acceleration time. |
| OC2 | Overcurrent during Deceleration | Excessive current during motor braking or deceleration. | Deceleration ramp too short, dynamic braking threshold exceeded. | Extend deceleration time, check brake chopper resistor. |
| OC5 | I x t Motor / Inverter Overload | Continuous current overload exceeded allowed limit. | Drive undersized for mechanical load, prolonged stall or mechanical binding. | Check drive loading, verify mechanical movement, verify continuous current setting. |
| OU | DC Bus Overvoltage | DC bus voltage exceeded upper limit (>770 V DC / 800 V DC). | Regenerative energy from motor overload during braking, brake resistor disconnected or defective, mains voltage too high. | Check brake resistor and brake chopper configuration, measure mains voltage, extend deceleration time. |
| LU | DC Bus Undervoltage | DC bus voltage dropped below lower threshold (<400 V DC or <285 V DC). | Mains voltage failure, line phase loss, input fuse blown, main power interrupted. | Check mains voltage input supply, verify line fuses and main switch contactor. |
| OH | Heatsink Over-temperature | Drive heatsink temperature exceeded maximum threshold (>90 °C). | Fan failure, blocked cooling vents, ambient temperature too high, continuous overload. | Clean heatsink cooling fins, verify cabinet fan operation and ambient air supply. |
| OH4 | Motor Over-temperature (PTC / Thermal Sensor) | Motor temperature sensor (PTC/KTY) tripped on input terminal X10/T1,T2. | Motor thermal overload, insufficient motor cooling, defective sensor wiring. | Allow motor to cool down, inspect external motor fan, measure motor sensor resistance. |
| CE0 | AIF Communication Error | Communication failure between inverter control board and AIF module. | Loose fieldbus plug, improper grounding, network master timeout, defective AIF module. | Check connection of option card in AIF slot, inspect fieldbus cabling and bus terminations. |
| CE1 | CAN System Bus Communication Error (CAN-IN1) | CAN system bus telegram interruption on input object 1. | Broken CAN bus wire, missing termination resistor, bad baud rate setting. | Check CAN wiring, verify 120 ohm termination resistors at both ends of CAN line. |
| CE2 | CAN System Bus Communication Error (CAN-IN2) | CAN system bus telegram interruption on input object 2. | CAN line noise or connection loss. | Check CAN cabling and node configuration. |
| Sd1 | Resolver / Feedback Error | Resolver signal loss or track error on connector X7. | Resolver cable unplugged, damaged resolver feedback line, excessive shield interference. | Inspect resolver cable, shielding, connector X7, and motor feedback unit. |
| Sd2 | Encoder Signal Fault | Absolute encoder or incremental encoder signal error on X8. | Encoder supply voltage drop, damaged cable, signal track corruption. | Verify encoder pinout, supply voltage, and cable shielding. |
| PR | Parameter Set Error | Inconsistent or corrupted parameter memory detected on startup. | Interrupted parameter upload/download, corrupted EEPROM memory. | Reload factory default parameter set (C0002) and reconfigure drive. |
| H05 | Internal Hardware Fault | Internal board failure or microcontroller self-test failure. | Defective internal control board, corrupted internal CPU flash. | Internal hardware fault — return unit for repair or replace drive module. |
| NMAX | Speed Overspeed Fault | Motor speed exceeded maximum allowable threshold setting. | Inappropriate control tuning, runaway load, faulty encoder reading. | Check speed controller gains, encoder wiring, and drive speed limit parameters. |
Frequently Asked Questions
What software is used to program and commission the Lenze EVS9327-ES?
The EVS9327-ES is programmed and commissioned using Lenze Global Drive Control (GDC) PC software or configured directly using the pluggable EMF2102IB XT Keypad Operating Module.
Which fieldbus communication modules are compatible with the EVS9327-ES AIF slot?
The Automation Interface (AIF) slot supports optional communication modules including the EMF2133IB PROFIBUS DP card, the EMF2173IB DeviceNet card, as well as INTERBUS and LECOM serial interfaces.
How are parameters transferred to a replacement EVS9327-ES drive?
Parameters can be transferred by saving and copying the parameter sets using the pluggable EMF2102IB keypad module or by uploading and downloading the parameter file via Global Drive Control (GDC) software into the replacement unit's EEPROM memory.
What does a solid Red LED mean on the front panel?
A solid Red LED indicates a TRIP fault state, meaning the inverter drive is inhibited due to an active fault condition such as an overcurrent, overvoltage, or thermal error.
What should I do if the drive displays fault code H05?
Fault code H05 indicates an internal hardware failure or microcontroller self-test failure. This internal board-level fault cannot be fixed through parameter adjustments and requires returning the unit for repair or replacing the drive module.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.