Lenze 13431381 EVS9322-EK – 9300 Servo Inverter Drive 0.75 kW

New 
On request
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Servo | Series: 9300 Servo Inverter

The Lenze 13431381 EVS9322-EK is a panel-mounted 0.75 kW servo inverter drive from the Lenze 9300 Servo family, engineered for dynamic control of synchronous and asynchronous servo motors. Operating on a three-phase AC supply voltage ranging from 320 V to 528 V AC, this unit delivers a continuous rated current of 2.5 A and supports a 150% peak current capacity of 3.75 A for up to 60 seconds. Utilizing field-oriented vector control, the drive achieves precise torque, speed, and position regulation across an output frequency range up to 480 Hz with an 8 kHz switching frequency.

Connecting the drive into an automated system is facilitated by built-in feedback interfaces, including a standard resolver input and incremental encoder channels. Network integration is handled through the integrated CAN System Bus running at 500 kbit/s, while optional fieldbus cards such as PROFIBUS-DP or LECOM RS232/RS485 can be installed into expansion Slot X1. When commissioning a spare drive, parameter sets stored in internal non-volatile EEPROM memory must be loaded to mirror the original controller settings. Commissioning technicians can transfer these parameters using Lenze Global Drive Control (GDC) software or clone them directly via the Keypad XT module inserted into Function Slot X2. ABC Industrial Parts can assist with supply and parameter management when preparing a replacement drive for installation.

Status and diagnostic evaluation rely on the STAT1 green LED and STAT2 red LED located on the front cover, alongside dedicated TRIP relay output contacts across terminals 28 and 29. A blinking green STAT1 LED confirms active controller operation, whereas a solid red STAT2 LED indicates an active TRIP condition resulting from faults such as output short circuits, DC bus overvoltage exceeding 770 V DC, or internal heatsink overtemperature above 85°C. Initial checks should include verifying 3-phase mains balance, motor cable insulation, and CAN bus termination resistors. When internal micro-controller faults or EEPROM memory errors occur, hardware components cannot be repaired in the field, making a tested replacement drive from ABC Industrial Parts the most efficient way to restore operational throughput.

Technical Specifications

Rated Power0.75 kW
Supply Voltage Range320 - 528 V AC (3-phase)
Rated Current2.5 A
Max Output Current3.75 A (150% for 60 s)
Max Output Frequency480 Hz
Switching Frequency8 kHz
Control MethodField-oriented vector control
Integrated System BusCAN (500 kbit/s)
TRIP Relay ContactsTerminals 28 / 29

Programming and Configuration

Configuration of the Lenze 13431381 EVS9322-EK drive is handled through the Lenze Global Drive Control (GDC) engineering software environment or using the portable Keypad XT unit (EMZ9371BC). System parameters governing speed controller gains, acceleration ramps, I²t thermal limits, and fieldbus node addresses are stored within non-volatile EEPROM memory embedded on the internal control board.

When replacing a unit, parameter transfer can be executed without a PC by connecting a Keypad XT to Function Slot X2, copying the dataset from the original drive, and loading it into the replacement drive. Alternatively, GDC software enables full parameter backup, online monitoring, and restoration over serial or fieldbus connections. Recommissioning requires verifying critical parameters, such as code C0002 for parameter set reset and restore operations and C0351 for system bus baud rates.

Communication and System Integration

The EVS9322-EK servo drive incorporates an onboard CAN System Bus interface accessible at terminals X4 and X5, operating at communication speeds up to 500 kbit/s for fast cross-communication between multiple Lenze 9300 Servo drives. Proper network topology requires standard 120-ohm termination resistors fitted at both physical ends of the CAN bus line.

For high-level industrial fieldbus communication, Automation Slot X1 accepts optional communication modules, including PROFIBUS-DP cards (EMF2133IB or EMF2131IB), INTERBUS modules, or LECOM RS232/RS485 interfaces. Feedback signal processing includes built-in inputs for resolvers and incremental encoders, enabling synchronized multi-axis motion and precise positioning within high-speed automated machinery.

Diagnostics and Status Indication

Diagnostic monitoring on the Lenze 13431381 drive combines hardware LED indicators with digital output signals and numerical fault code displays on the Keypad XT or GDC software. Physical relay contacts across terminals 28 and 29 serve as a dedicated TRIP output to inform the master PLC of a drive fault state.

Front-panel status indicators provide real-time operating status. The STAT1 LED displays drive activity and ready status, while the STAT2 LED signals active warnings, errors, or TRIP conditions requiring operator action.

Status LED Indicators

LEDColor/StatusMeaning
STAT1Green - Blinking / Solid / OffBlinking indicates drive active or controller enabled; solid light indicates ready or pulse inhibit; dark indicates unit unpowered or missing supply.
STAT2Red - Solid / FlashingContinuous light or fast flashing indicates TRIP active (drive fault); slow flashing indicates warning or error message active.

Replacement and Spare Part Considerations

Replacing a Lenze 13431381 (EVS9322-EK) servo drive requires ensuring the replacement unit matches the exact model number and electrical specification of 0.75 kW at 2.5 A continuous output. Prior to powering up a replacement unit, verify that input AC line voltage is balanced between 320 V and 528 V AC and that all motor output phases and shield connections are secure.

Because a replacement drive comes unconfigured or loaded with factory settings, parameter files must be transferred from the original unit or loaded from a machine backup. Parameter sets can be downloaded using Lenze GDC software or copied directly via the Keypad XT module. Verify that option cards installed in Slot X1, such as PROFIBUS communication modules, are transferred to the replacement unit and firmly seated before reconnecting fieldbus wiring.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Short circuit / Earth faultShort circuit or earth fault on output power terminals or motor phase linesShort circuit in motor cable; motor winding breakdown; earth fault in wiringCheck motor cable and motor windings for insulation fault/short circuit. If error persists with motor disconnected, internal power stage failure — contact service / return unit for repair.
OC2Earth faultEarth fault on output phase terminals during operationCapacitive leakage current in long motor cable; winding insulation fault to groundCheck motor cable length and grounding insulation; check motor insulation resistance.
OC5Overcurrent during accelerationOutput current exceeded allowed threshold during acceleration rampAcceleration time ramp set too short; mechanical load jammed or blocked; motor wrongly dimensionedIncrease acceleration time; check mechanical system for jams; verify motor parameter setting.
OUOvervoltage DC bus linkDC bus link voltage exceeded maximum limit (>770 V DC)Excessive regenerative energy during deceleration; brake chopper transistor inactive; braking resistor broken or incorrectly sizedExtend deceleration time ramps; check external braking resistor and brake module wiring.
LUUndervoltage DC bus linkDC bus link voltage dropped below minimum threshold (<430 V DC)Mains supply voltage too low; phase loss in mains supply; power supply failureCheck AC mains supply voltage and fuses; check incoming mains phase symmetry.
OHOvertemperature HeatsinkPower section heatsink temperature exceeded maximum threshold (>85°C)Cooling airflow restricted or dirty heatsink fins; cabinet fan failure; ambient temperature too highClean heatsink cooling fins; verify cabinet ventilation and fan function; reduce load or switching frequency.
OH4Overtemperature Inside UnitInternal temperature inside control section electronics exceeded maximum limit (>70°C)Control cabinet internal ambient temperature excessive; insufficient internal cabinet coolingImprove cooling inside control cabinet; inspect unit installation clearance.
OH7Motor Phase Failure / Motor OvertemperatureMotor thermal sensor (PTC / KTY / thermal contact) triggered thermal protection or motor phase interruptedMotor overloaded; motor cooling fan failure; motor sensor circuit wire brokenAllow motor to cool down; check motor load and cooling fan; verify temperature sensor connections at terminals T1/T2.
OH8Motor Overtemperature (I²t calculated)Calculated motor thermal load (I²t) reached 100% thresholdContinuous operation above rated motor current at low speedsCheck motor operating current; adjust I²t thermal monitoring settings (C0075/C0076); reduce motor load.
OEXExternal FaultExternal fault condition triggered via digital input assigned to External Fault functionExternal safety circuit or monitoring sensor opened contactInspect external equipment connected to assigned digital input.
EE0EEPROM Fault (Control Section)Internal non-volatile EEPROM communication or checksum errorData corruption during power-down or internal hardware memory faultReload factory default parameters (C0002 = 1). If fault persists, internal hardware defect — return unit for repair.
EE1EEPROM Fault (Power Section)Non-volatile memory fault on internal power module boardInternal hardware failure on power section boardCycle power to drive. If fault remains active, unserviceable internal board failure — return unit for repair.
EErEEPROM Read ErrorError reading operating parameters during power-up boot sequenceCorrupted parameter memory spaceRe-download complete parameter set from GDC or Keypad XT. If persistent, return unit for repair.
NMAXSpeed Limit ExceededActual motor speed exceeded configured maximum speed threshold (C0011) by >10%Incorrect speed controller tuning; overshooting load; wrong feedback resolution or scalingCheck speed controller gains (C0070/C0071); verify motor encoder/resolver feedback resolution.
H05Internal Hardware ErrorInternal micro-controller hardware fault or internal voltage monitoring errorControl board failure or defective internal voltage regulatorInternal control board hardware defect — not field serviceable. Return unit for repair or replace inverter.
P12Parameter FaultInconsistent or out-of-range parameter combination detected upon initializationIncompatible parameter download or invalid value set in configuration codeRestore factory defaults (C0002) and re-commission parameters using Lenze GDC.
CE0Communication Error Slot X1Communication failure between inverter control board and optional fieldbus module in Slot X1Loose fieldbus card connection; fieldbus cable disconnected; master PLC stopped communicationCheck plug-in seated connection of module in Slot X1; check network cable connections and PLC communication state.
C01System Bus Fault (CAN)Communication interruption or bus-off state detected on integrated System Bus (X4/X5)CAN bus wire broken or shorted; missing bus termination resistors (120 Ohm); incorrect baud rate settingVerify CAN bus wiring, shield grounding, and termination at both ends of the network; check baud rate setting C0351.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze EVS9322-EK drive?

Parameters can be transferred using the Keypad XT module (EMZ9371BC) inserted into Function Slot X2 to clone data directly between drives, or by downloading the saved parameter set using Lenze Global Drive Control (GDC) PC software.

What option modules can be fitted into expansion Slot X1?

Automation Slot X1 supports communication option cards including PROFIBUS-DP modules (EMF2133IB and EMF2131IB), INTERBUS modules, and LECOM RS232/RS485 communication cards.

What causes an OU fault on the Lenze 13431381 drive?

An OU fault indicates that the internal DC bus voltage has exceeded 770 V DC. This is typically caused by excessive regenerative braking energy during deceleration, an inactive brake chopper, or a damaged external braking resistor.

What does a solid red STAT2 LED indicate?

A solid red STAT2 LED indicates an active TRIP condition, meaning the drive has shut down due to a system fault such as overcurrent, DC bus overvoltage, or thermal overload.

Can internal hardware errors like fault H05 or EE0 be fixed on-site?

Internal micro-controller faults (H05) or persistent EEPROM memory errors (EE0 or EE1) indicate hardware failures on internal printed circuit boards. These conditions are not field-serviceable and require unit replacement or repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.