Lenze 13432619 EVF9325-EV 9300 Vector Frequency Inverter

New 
1 available for direct collection
Refurbished   
1 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 9300 Vector

The Lenze EVF9325-EV frequency inverter, designated by part number 13432619, is a 5.5 kW drive unit within the Lenze 9300 Vector series designed for precise speed and torque control in automated production environments. Operating across a 3-phase supply voltage range of 320 V AC to 528 V AC, this compact IP20-rated drive supplies a continuous current of 13 A at 400 V AC (11 A at 480 V AC) and delivers a maximum peak output current of 19.5 A with a 150% overload capacity for up to 60 seconds. The unit supports versatile control methods including sensorless vector control, torque control, and programmable V/f characteristics over an output frequency range of 0 Hz to 480 Hz with an 8 kHz switching frequency, making it suitable for material handling conveyors, industrial fans, pumps, packaging machinery, and agitators requiring robust startup performance.

System integration and control wiring are facilitated through six 24 V DC digital inputs, two digital outputs, two bipolar analog inputs (-10 V to +10 V or 4-20 mA), and two analog outputs alongside terminal X1 TRIP relay contacts. For network communication, the drive features an onboard CAN system bus supporting transfer rates up to 500 kbit/s for motion synchronization between drives. A modular Automation Interface (AIF) slot accepts optional communication modules, including PROFIBUS-DP (EMF2133IB / EMF2131IB), LECOM RS232/RS485 (EMF2102IB / EMF2111IB), or an interactive Keypad XT (EMZ9371BC) display. Internal non-volatile EEPROM memory stores up to four independent parameter sets, allowing engineers to back up drive settings or transfer complete program profiles using Lenze Global Drive Control (GDC) software or the plug-in keypad. When replacing a unit, matching parameter configurations and transferring settings from the old drive is essential before putting the spare into service, a process where technical support from ABC Industrial Parts can assist in ensuring operational readiness.

Drive operation and active operating states are indicated on the front panel via three diagnostic LEDs: Green (Ready / Controller enable), Yellow (IMP / Warning pulse inhibit), and Red (TRIP / Fault state). System technicians can inspect the integrated fault history buffer across parameters C0161 to C0164 using Keypad XT or GDC software to identify specific active or historical fault codes such as overvoltage (OU), undervoltage (LU), phase failure (LP1), overcurrent (OC1, OC2, OC5), and overtemperature conditions (OH, OH4, OH7). Diagnostic checks should begin by verifying line supply voltages across L1, L2, and L3, checking motor winding insulation, verifying AIF module seating, and confirming proper 120-ohm CAN bus termination. In situations involving internal component degradation, fan failure (H10), or memory corruption (EER), internal hardware faults are not field-serviceable, making drive repair or a fully tested exchange replacement unit from ABC Industrial Parts the most reliable path back to production.

Technical Specifications

ManufacturerLenze
Part Number13432619
Model / TypeEVF9325-EV
Product Family9300 Vector
Component TypeFrequency Inverter
Rated Power5.5 kW
Supply Voltage Range320 - 528 V AC
Rated Current (400V)13 A
Output Current (480V)11 A
Maximum Output Current19.5 A
Control MethodSensorless Vector / V/f Characteristic
Output Frequency0 - 480 Hz
Switching Frequency8 kHz
Digital Inputs6
Digital Outputs2
Analog Inputs2
Analog Outputs2
System Bus ProtocolCAN / CANopen (500 kbit/s)
IP RatingIP20

Programming and Configuration

The Lenze EVF9325-EV is configured using Lenze Global Drive Control (GDC) engineering software or the portable Keypad XT module (EMZ9371BC). Drive parameters control speed ramps, current limits, control modes, and I/O assignments across the frequency inverter's operating ranges.

An onboard non-volatile EEPROM retains up to four complete, independent parameter sets without requiring continuous battery backup. This feature enables rapid profile switching and allows maintenance personnel to clone functional drive configurations directly to donor hardware during field maintenance.

Standard factory default settings can be restored by setting parameter C0002 to value 1 via the keypad or GDC software interface. Following a factory reset, custom motor data, application settings, and fieldbus parameters must be reloaded to re-establish machine control.

Communication and System Integration

Drive-to-drive motion control and distributed automation are supported through an integrated CAN system bus operating at speeds up to 500 kbit/s. Terminal connections facilitate multi-axis drive synchronization and high-speed data exchange using CAN/CANopen protocols.

The modular Automation Interface (AIF) slot on the front housing accepts optional communication adapters to integrate with various fieldbus networks. Supported options include PROFIBUS-DP modules (EMF2133IB / EMF2131IB) and LECOM RS232/RS485 interfaces (EMF2102IB / EMF2111IB), enabling communication with central PLCs or higher-level control systems.

Diagnostics and Status Indication

Operational states and system faults are displayed locally on the inverter housing using three status LEDs. The Green LED remains solid when power is applied and controller enable is active. The Yellow LED indicates a pulse inhibit state or warning condition, while a solid or blinking Red LED indicates an active TRIP condition with drive outputs disabled.

Advanced troubleshooting is conducted by accessing the fault history buffer (parameters C0161 to C0164) through Keypad XT or GDC software. The TRIP relay contact on terminal X1 provides a physical dry-contact output to signal external PLC logic when an alarm condition occurs.

Status LED Indicators

LEDColor/StatusMeaning
Red LED (TRIP)Red - Solid / BlinkingFault/Error state active. Drive output is inhibited (TRIP state). Blinking indicates specific fault conditions or warning state.
Green LED (Ready)Green - SolidDrive is powered and operational (Ready / Controller enable). Normal operating mode with pulses enabled.
Yellow LED (IMP / Warning)Yellow - SolidPulse inhibit active / Warning condition present. Output power stage is locked.

Replacement and Spare Part Considerations

When replacing an existing EVF9325-EV drive (part number 13432619), the replacement unit must match the voltage rating (320–528 V AC) and continuous output current capacity (13 A at 400 V AC) of the original unit. Ensure that any installed AIF fieldbus communication module or Keypad XT display is transferred from the old drive to the replacement housing's AIF slot.

Parameter sets stored in the original inverter's EEPROM should be downloaded using GDC software or saved to a Keypad XT module prior to swapping hardware. After installing the replacement unit, parameter data must be written to the drive's memory to ensure proper motor tuning, I/O terminal functions, and network node settings before enabling system operation.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OHOvertemperature HeatsinkDrive heatsink temperature exceeded maximum safety threshold.Cooling fan failed, cooling fins clogged with dirt, ambient temperature too high, or excessive drive overload.Clean heatsink, ensure adequate cabinet ventilation, verify fan operation, reduce load/ambient temperature.
OH4Overtemperature Motor (PTC)Motor temperature sensor (PTC/TK) connected to terminals triggered motor protection.Motor overload, inadequate motor cooling, defective temperature sensor or loose wire connection.Allow motor to cool, check motor load and cooling fan, inspect PTC wiring at control terminal.
OH7Overtemperature Drive InteriorInternal temperature inside the inverter enclosure exceeded safe limit.Control cabinet cooling inadequate, internal drive fan failure.Improve cabinet ventilation, check internal fan.
OC1Overcurrent - Short Circuit / AccelerationInstantaneous peak current threshold exceeded during motor acceleration.Short circuit or ground fault in motor cable, acceleration ramp time too short, motor improperly sized or jammed.Check motor cable and winding insulation, increase acceleration ramp time (C0012), check mechanical load.
OC2Overcurrent - DecelerationInstantaneous peak current threshold exceeded during motor deceleration.Deceleration ramp time too short, short circuit in motor output.Increase deceleration ramp time (C0013), install braking resistor if necessary.
OC5Overcurrent - I2t Motor LoadContinuous motor overload detected by internal I2t monitoring algorithm.Motor continuously overloaded or running at low speed with excessive load.Check motor current against rated value, check load mechanics, adjust C0075 / I2t monitoring settings.
OUOvervoltage DC BusDC bus link voltage exceeded upper threshold limit (> 770 V DC).Excessive regenerative energy during deceleration without braking resistor, deceleration ramp too short, mains voltage spike.Extend deceleration time, connect external braking module/resistor, inspect mains voltage stability.
LUUndervoltage DC BusDC link bus voltage fell below minimum allowable threshold (< 400 V DC).Mains supply failure, supply voltage too low, phase missing, or charging circuit fault.Check supply voltage, inspect mains fuses and wiring, verify power supply connections.
LP1Mains Phase FailureOne phase of the 3-phase AC input supply missing.Blown input fuse, loose power wiring, or unbalanced mains supply.Check input voltage across all 3 phases (L1, L2, L3) and input fuses.
EEREEPROM Memory ErrorInternal EEPROM checksum error or corrupted parameter memory.Power failure during parameter save, internal EEPROM memory fault.Reload factory default parameters (C0002 = 1) and reload program. Internal hardware fault — return unit for repair if fault persists.
CE0CAN Communication Error / Time-outCommunication failure or time-out detected on the internal System Bus (CAN).CAN cable disconnected, incorrect bus baud rate, missing terminating resistor, network interference.Check CAN bus wiring, shield grounding, 120-ohm termination resistors, and node ID settings.
AIF-EAIF Communication FaultCommunication fault between the drive control board and the Automation Interface (AIF) module.Fieldbus communication module not properly seated, module failure, fieldbus cable break.Check plug-in connection of the AIF module, inspect fieldbus master and network cabling.
NMAXMaximum Speed ExceededActual motor speed exceeded maximum allowable limit (C0011 + overspeed tolerance).Uncontrolled overhauling load, improper speed controller tuning, encoder loss.Check mechanical load, review speed controller settings, check speed feedback.
H10Heatsink Fan FaultInternal cooling fan current or rotation monitor failed.Fan blocked, disconnected, or defective.Inspect fan for debris or mechanical blockages; replace cooling fan assembly.

Frequently Asked Questions

What software is required to configure the Lenze EVF9325-EV inverter?

The drive is configured using Lenze Global Drive Control (GDC) software via a PC connection or locally using the plug-in Keypad XT module (EMZ9371BC).

How can parameters be transferred when replacing an EVF9325-EV drive?

Parameter sets saved in the internal EEPROM can be transferred to a replacement unit by saving the configuration to a Keypad XT module or backing up the project file in GDC software and loading it into the spare inverter.

What do the LED status indicators on the front panel signify?

The Green LED indicates normal operation with controller enable active, the Yellow LED indicates a pulse inhibit or warning state, and the Red LED indicates an active TRIP fault condition.

Which fieldbus interfaces are compatible with the EVF9325-EV AIF slot?

The AIF slot supports optional plug-in modules including PROFIBUS-DP (EMF2133IB / EMF2131IB) and LECOM RS232/RS485 (EMF2102IB / EMF2111IB).

What causes an EER fault code on the EVF9325-EV?

An EER code indicates an internal EEPROM checksum error or memory corruption, often caused by power interruption during a parameter save operation or internal memory failure. Restoring defaults (C0002 = 1) may resolve soft errors.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.