Lenze 13432636 EVF9326-EV 9300 Vector 15 kW Frequency Inverter
Het item werd toegevoegd aan uw offerteaanvraag
Product Information
The Lenze 13432636 EVF9326-EV is a 15 kW frequency inverter from the 9300 Vector series designed for precise AC induction motor control in industrial automated machinery. Operating on a three-phase nominal supply voltage of 400 V AC or 480 V AC across an operational input range of 320 to 528 V AC, this IP20-rated drive supplies a continuous output current of 32 A at 400 V and 27 A at 480 V. It provides accurate velocity and dynamic torque regulation across an output frequency range of 0 to 480 Hz with an 8 kHz switching frequency using either field-oriented vector control or customizable V/f characteristic control. Integrated function blocks support internal PID process loops, logic functions, programmable acceleration ramps, and brake chopper control.
For system connectivity, the unit includes an onboard CANopen system bus operating at up to 500 kbit/s for inter-drive networking, alongside a front Automation Interface Slot (AIF) that accepts plug-in fieldbus communication modules such as PROFIBUS-DP (EMF2133IB), DeviceNet (EMF2173IB), and INTERBUS (EMF2113IB). Commissioning a replacement spare requires transferring device settings, as drives are rarely ready to run straight out of the box. Up to four parameter sets can be stored in non-volatile internal memory and uploaded or downloaded using Lenze Global Drive Control (GDC) software v4.x or v5.x, or copied directly using an optional XT Keypad Module (EMF2102IB). ABC Industrial Parts can assist maintenance teams with pre-configuring replacement units and backing up application parameters to ensure smooth installation.
Operational status and active faults are indicated via front status LEDs, where a solid green light signals readiness, a flashing green light shows operation suppressed or drive inhibited, and a red light indicates an active TRIP condition. In-depth diagnostics are accessible via code C0059 for current TRIP status and code C0168 for the internal fault history buffer, viewable through the XT Keypad or GDC oscilloscope and diagnostic tools. Errors such as overcurrent (OC1, OC2, OC5), overvoltage (OU), undervoltage (LU), or overtemperature (OH, OH4, OH7) can often be resolved by verifying field wiring, motor insulation, line fuses, or cooling arrangements. When diagnostic codes such as H05 or EER indicate unrecoverable microcontroller, EEPROM, or internal output stage failures, field repair is not possible, making a tested replacement drive or specialized repair service through ABC Industrial Parts the quickest route to restore production.
Technical Specifications
| Manufacturer | Lenze |
| Part Number | 13432636 |
| Model / Type | EVF9326-EV |
| Product Family | 9300 Vector |
| Component Type | Frequency Inverter |
| Rated Power | 15 kW |
| Supply Voltage Range | 320 - 528 V AC |
| Nominal Supply Voltage | 400 / 480 V AC (3-phase) |
| Continuous Output Current (400V) | 32 A |
| Continuous Output Current (480V) | 27 A |
| Output Frequency Range | 0 - 480 Hz |
| Switching Frequency | 8 kHz |
| Digital Inputs | 4 |
| Digital Outputs | 2 |
| Analog Inputs | 2 |
| Analog Outputs | 2 |
| Onboard System Bus | CANbus / CANopen (500 kbit/s) |
| Expansion Interface | Automation Interface Slot (AIF) |
| Enclosure Rating | IP20 |
Programming and Configuration
Programming and parameter setup for the Lenze 13432636 EVF9326-EV frequency inverter is carried out using Lenze Global Drive Control (GDC) software version 4.x or 5.x, or locally via the EMF2102IB XT Keypad Module. The drive features non-volatile internal storage capable of holding up to four complete, independent parameter sets, allowing versatile operational profiles for complex machines.
Parameter sets can be transferred between drives by copying data directly to the XT Keypad or uploading and downloading parameter files using GDC software. Key codes are utilized for quick drive management, such as code C0002 to execute a factory default reset or code C0011 to set the maximum motor speed limit.
Communication and System Integration
The EVF9326-EV incorporates an onboard system bus based on CANopen, providing high-speed drive-to-drive communication and multi-axis synchronization at data rates up to 500 kbit/s. Proper network operation requires correct line termination with 120 Ohm resistors at both ends of the CAN bus and matched baud rate settings across all connected nodes.
A front-facing Automation Interface Slot (AIF) allows modular expansion into higher-level fieldbus networks. By installing option cards such as the EMF2133IB for PROFIBUS-DP, EMF2173IB for DeviceNet, or EMF2113IB for INTERBUS, the drive integrates seamlessly into automated control architectures and PLC systems.
Diagnostics and Status Indication
The drive provides real-time operational state tracking and diagnostic tools through status LEDs and internal memory monitors. Current fault states are logged under parameter code C0059, while historic fault events are preserved in the internal history buffer under code C0168.
Maintenance technicians can perform live monitoring, trace system variables, and review fault logs using the GDC software diagnostic window and oscilloscope functions or directly via the XT Keypad module display.
Status LED Indicators
| LED | Color/Status | Meaning |
|---|---|---|
| Ready | Green - Solid | Inverter ready for operation |
| Ready | Green - Flashing | Drive inhibited or operation suppressed |
| Fault | Red - Solid or Flashing | TRIP or fault message active |
Replacement and Spare Part Considerations
When replacing an existing 13432636 EVF9326-EV inverter in an operational line, it is essential to ensure exact part number matching and parameter alignment. The replacement unit must be loaded with the active parameter set from the original drive using GDC software or an EMF2102IB XT Keypad module before enabling motor output.
In addition to parameter set transfer, any installed plug-in communication card (such as PROFIBUS-DP or DeviceNet) must be transferred to the new drive's AIF slot, and network address settings and baud rates verified. Check that motor thermal protection wiring (PTC on terminals T1/T2), line protection fuses, and external braking resistors are properly connected prior to commissioning.
Error Codes & Fault Codes
The following error codes may be displayed during operation or diagnostics:
| Code | Name | Description | Possible Cause | Recommended Action |
|---|---|---|---|---|
| OC1 | Short Circuit / Ground Fault | Short circuit or ground fault at output power terminals or motor windings. | Short circuit in motor cables or motor; ground fault; excessive ramp acceleration rate. | Check motor and wiring for short circuits and insulation faults; increase acceleration time; check drive output stage. If persistent without connected load, internal power stage is damaged and requires repair or drive replacement. |
| OC2 | Earth Fault | Earth/ground fault detected on motor phase leads. | Insulation failure in motor cable or motor winding; excessive capacitive charging current in long motor cables. | Check motor insulation resistance with megohmmeter; inspect cabling; verify maximum cable lengths. |
| OC5 | Overcurrent during Acceleration | Output current exceeded internal threshold during motor acceleration stage. | Acceleration time too short; motor mechanically blocked or overloaded; incorrect motor parameter settings. | Increase acceleration ramp time; check mechanical load for jamming; verify nameplate motor parameters in parameter set. |
| OU | Overvoltage DC Bus | DC bus voltage exceeded upper limit threshold. | Regenerative motor braking energy too high; deceleration ramp too steep; missing or failed brake resistor/brake chopper. | Increase deceleration ramp time; install or verify external brake resistor; check mains supply voltage. |
| LU | Undervoltage DC Bus | DC bus voltage fell below lower operational limit. | Mains supply voltage too low; phase failure on incoming AC supply; mains supply power outage. | Check mains voltage levels across all phases; check incoming line fuses and contactors. |
| OH | Heatsink Overtemperature | Drive heatsink temperature exceeded maximum allowed limit. | Inadequate control cabinet ventilation; clogged heatsink cooling fins; cooling fan failure; ambient temperature too high. | Clean heatsink cooling fins; check internal fan operation; ensure proper cabinet ventilation and ambient temperature limits. |
| OH4 | Motor Temperature Fault | Motor temperature sensor input triggered or PTC circuit opened on terminals T1/T2. | Motor thermal overload; motor PTC sensor triggered; open circuit in PTC wiring. | Allow motor to cool down; inspect motor cooling and mechanical loading; check PTC temperature sensor wiring. |
| OH7 | Internal Drive Overtemperature | Temperature inside internal drive enclosure exceeded permissible limit. | High ambient temperature inside control cabinet; internal cooling fan failure. | Check cabinet air circulation; replace faulty drive internal cooling fans. |
| CE0 | Communication Error AIF Interface | Communication failure or module fault on plugged automation interface module (AIF). | Loose module; damaged fieldbus option card; network communication timeout. | Ensure option module is securely seated in AIF slot; check fieldbus cabling and termination resistors; replace option module. |
| CE1 | CAN System Bus Communication Error (CAN-IN1) | Time-out or failure on onboard system bus CAN communication. | Interrupted bus cable; missing termination resistors; CAN baud rate mismatch; master controller offline. | Check CAN bus cable continuity, grounding, and 120 Ohm termination resistors at both network ends; check baud rate setting. |
| EER | EEPROM Memory Error | Internal EEPROM memory checksum fault during parameter store or power-up sequence. | Internal hardware failure; corrupted internal memory during power interruption while saving parameters. | Perform factory default reset using C0002. If error cannot be cleared, internal EEPROM hardware has failed — unit must be replaced or returned for repair. |
| H05 | Internal Hardware Error | Internal micro-controller or internal power board monitoring fault. | Board level electronic component defect. | Cycle power to drive. If fault persists, this is an internal board hardware failure — unit must be sent for factory service or replaced. |
| LP1 | Motor Phase Failure | Failure detected in one or more motor output phases. | Interrupted motor phase lead; motor contactor open; extremely small motor connected relative to drive rating. | Check motor cable connections and phase wiring; verify output contactor operation. |
| NMAX | Speed Limit Exceeded | Actual motor velocity exceeded maximum programmed speed limit threshold. | Incorrect feedback setup or overhauling mechanical load. | Check max speed parameter C0011; check load dynamics and brake application. |
Frequently Asked Questions
What software is required to configure the Lenze 13432636 EVF9326-EV drive?
Configuration and parameter management are supported using Lenze Global Drive Control (GDC) software version 4.x or 5.x, or locally via the optional EMF2102IB XT Keypad Module.
How do I transfer parameters from a failed EVF9326-EV drive to a spare unit?
If the original drive memory is accessible, parameters can be copied to an EMF2102IB XT Keypad module or uploaded using GDC software and then downloaded into the replacement unit's non-volatile memory.
What does fault code H05 indicate on this drive?
Fault code H05 indicates an internal hardware error within the microcontroller or power monitoring circuits. If cycling power does not clear the error, the drive has an internal board fault requiring component repair or replacement.
Which fieldbus modules can be added to the EVF9326-EV?
The drive features an Automation Interface Slot (AIF) that accepts plug-in modules including PROFIBUS-DP (EMF2133IB), DeviceNet (EMF2173IB), and INTERBUS (EMF2113IB).
What are the electrical power ratings for the EVF9326-EV inverter?
The EVF9326-EV is rated at 15 kW and operates on a 3-phase 320 to 528 V AC mains supply (400/480 V nominal), delivering 32 A continuous output at 400 V AC and 27 A at 480 V AC.
Take advantage of our exchange formula
A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.
Play it safe with our warranty conditions
Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.
Data backup and recovery
Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.
Specific firmware and hardware versions
If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.
Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.



