Lenze 13466006 E84AVBDE3712SX0 0.37kW 8400 BaseLine Inverter

New 
On request
Refurbished   
4 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8400 | Series: 8400 BaseLine

The Lenze 13466006, model designation E84AVBDE3712SX0, is a compact frequency inverter from the 8400 BaseLine product series. Designed for variable-speed AC motor control in standardized motion tasks, this IP20-rated cabinet unit delivers a rated output power of 0.37 kW with a nominal output current of 2.4 A and a maximum output current of 3.6 A. Operating on a 230 V AC main supply across an allowable input voltage range of 180 V AC to 264 V AC in either single-phase or three-phase configurations, the drive provides an adjustable output frequency range from 0 to 599 Hz. It supports both V/f characteristic curve control and sensorless vector control (SLVC) modes to manage three-phase asynchronous motors across material handling conveyors, ventilation fans, and general machinery.

Control interface hardware on the E84AVBDE3712SX0 includes four programmable digital inputs, one digital status output, and one configurable analog input. Networking across fieldbus systems is supported via a built-in CANopen interface, where node address and baud rate settings are configured directly using onboard DIP switches. Commissioning or parameter adjustments are handled through Lenze EASY Starter software, connecting via the front X400 diagnostic port with an E84AYCCA USB adapter or a handheld keypad. Putting a replacement drive into operation is streamlined by the pluggable E84AYM20 EEPROM memory module, which holds all parameter configurations. Swapping this memory chip into a replacement chassis transfers parameters without specialized software, while ABC Industrial Parts can assist with parameter verification or replacement unit preparation when field equipment must be restored rapidly.

Diagnostic information is displayed directly through four status LEDs mounted on the drive front: DRIVE-READY, DRIVE-ERR, CAN-RUN, and CAN-ERR. The green DRIVE-READY LED indicates operational readiness when solid or inhibited modes when flashing, while the red DRIVE-ERR LED signals active warnings when flashing and solid trip faults when illuminated continuously. Advanced fault diagnosis is accessible by reading out the error history buffer through CANopen SDOs or EASY Starter software. When error conditions such as internal microcontroller self-test failures or output short circuits persist after power cycling, internal component failure is present that cannot be serviced in the field. Under these circumstances, exchanging the unit with a tested spare from ABC Industrial Parts or submitting the drive for repair provides a direct route to minimize equipment downtime.

Technical Specifications

ManufacturerLenze
Part number13466006
Model / TypeE84AVBDE3712SX0
Product family8400 BaseLine
Component typeFrequency Inverter
Rated power0.37 kW
Supply voltage1/N/PE AC 230 V / 3/PE AC 230 V
Supply voltage range180 V AC - 264 V AC
Rated current2.4 A
Max output current3.6 A
Output frequency range0 - 599 Hz
Switching frequency8 kHz
Control methodV/f Control, Sensorless Vector Control (SLVC)
Digital inputs4
Digital outputs1
Analog inputs1
Protection ratingIP20
Integrated fieldbusCANopen

Programming and Configuration

Drive setup and parameterization for the Lenze 13466006 inverter are managed using Lenze EASY Starter commissioning software. Engineering tasks are performed by connecting a PC to the dedicated X400 diagnostic port using an E84AYCCA USB diagnostic adapter. Operating parameters can also be edited directly at the drive hardware using an optional handheld keypad plugged into the X400 interface.

The 8400 BaseLine drive features a pluggable E84AYM20 EEPROM memory module that stores the complete parameter set of the inverter. When servicing or swapping out hardware, the memory module can be unplugged from the faulty unit and inserted into an identical replacement E84AVBDE3712SX0 drive, allowing immediate transfer of machine configurations without reconnecting software tools.

If memory module data becomes corrupted or requires reformatting, EASY Starter software provides utility procedures to clear and re-write the memory structure. Drive maintenance routines also support reading out the internal error history buffer to track historical fault events and operating anomalies during commissioning.

Communication and System Integration

The E84AVBDE3712SX0 frequency inverter includes a built-in CANopen fieldbus interface as standard, enabling direct integration into automated control architectures without requiring optional communication cards. Network settings, such as node address allocation and baud rate selection, are configured manually using integrated DIP switches located on the drive assembly.

The physical control interface consists of four digital inputs, one digital output, and one analog input that accepts configurable voltage or current setpoint signals. Network communication protocols operate over the CANopen bus to provide remote start/stop control, speed setpoint transfers, and status monitoring via Service Data Objects (SDO) and Process Data Objects (PDO).

Diagnostics and Status Indication

Front-panel status monitoring on the Lenze 13466006 drive is facilitated by four status LEDs that indicate drive operating state and network health. The DRIVE-READY LED shows operational readiness or inhibition, while the DRIVE-ERR LED signals active warnings or drive-inhibiting trip conditions. Network status is tracked by the CAN-RUN and CAN-ERR LEDs, which indicate active CANopen bus communication and bus error states such as error-passive or bus-off conditions.

In addition to visual LED indicators, comprehensive diagnostic feedback is available through the X400 diagnostic port using the E84AYCCA USB adapter or a keypad. Maintenance technicians can access the error history buffer via EASY Starter software or CANopen SDO messages to identify root causes of drive trips and operational faults.

Status LED Indicators

LEDColor/StatusMeaning
DRIVE-READYGreen - Solid / FlashingSolid green = drive ready/operational; Flashing green = drive inhibited or in operation mode.
DRIVE-ERRRed - Solid / FlashingFlashing red = warning/trouble active; Solid red = active fault (drive inhibited). Persistent error after power cycle indicates potential internal hardware fault.
CAN-RUNGreen - Documented BehaviorCANopen network operational state indicator.
CAN-ERRRed - Documented BehaviorCANopen bus error indicator (bus off, error passive, or frame errors).

Replacement and Spare Part Considerations

When replacing a Lenze 13466006 frequency inverter, maintenance personnel must confirm that the replacement chassis matches the model designation E84AVBDE3712SX0 and input voltage rating of 230 V AC. Because parameters are stored on the pluggable E84AYM20 memory module, device replacement can be accomplished by moving the existing memory module from the original drive to the replacement unit without needing to re-enter parameters or re-commission the system over software.

Before putting the replacement drive into service, check that the hardware DIP switch settings for CANopen node address and baud rate match the original unit's settings if fieldbus networking is used. Wiring connections to the digital and analog terminals must also be verified against original schematics to prevent signal mismatches.

If a replacement unit generates memory module fault 0x0061 after module transfer, verify that the module is firmly seated in its slot or use EASY Starter to check data integrity. For installations undergoing complete hardware modernization, the Lenze i550 series serves as the recommended successor platform.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
0x0011OC1 Short circuit / Earth faultShort circuit or earth fault detected at motor output stagesShort circuit in motor cable, earth fault in motor winding, motor power rating too large for driveCheck motor and wiring for short circuit/earth fault. If fault occurs with motor disconnected, internal power module is damaged — return unit for repair.
0x0012OC2 Overcurrent outputInstantaneous output overcurrent threshold exceededExcessive acceleration rate, mechanical jam/stall on motor shaft, sudden load shockIncrease acceleration time, check motor load and mechanical system for jamming.
0x0021OU Overvoltage DC busDC bus intermediate circuit voltage exceeded upper limitRegenerative energy from motor during deceleration, deceleration ramp too short, missing brake resistorExtend deceleration time ramp, install/check brake resistor or brake module.
0x0022LU Undervoltage DC busDC bus intermediate circuit voltage dropped below low thresholdMains supply voltage too low, line phase failure, power supply interruptionCheck main AC supply voltage, check supply fuses and line contactor.
0x0031OH Heatsink overtemperatureDrive heatsink temperature exceeded permissible maximum limitInadequate cooling air circulation, ambient temperature too high, dirty/blocked heatsink finsClean heatsink, check control cabinet ventilation and ambient temperature.
0x0032OH Inside overtemperatureInternal component temperature inside drive housing too highEnclosure ventilation failure, high ambient temperature, continuous overloadImprove cooling inside control cabinet, lower switching frequency or load.
0x0041Motor Overload (I²t)Thermal motor monitoring (I²t) triggeredMotor operated at low speed with high continuous load, motor undersized, incorrect motor thermal parameter settingsCheck motor size and load duty cycle, check motor thermal protection settings.
0x0051CE0 CANopen Communication ErrorCANopen communication monitoring timeout / bus offInterrupted CAN bus wire, missing termination resistor, wrong baud rate setting, CAN master stoppedCheck CANbus wiring, termination resistors (120 Ohm), DIP switch settings, and master controller status.
0x0061ETP Memory Module ErrorError accessing the inserted memory module E84AYM20Memory module missing, loose connection, or parameter data corruptedRe-seat memory module. If error persists, reformat memory module via EASY Starter or replace memory module.
0x0071Internal Hardware FaultInternal micro-controller or circuit failure detected during self-testInternal electronic board component failureInternal hardware failure — non-field serviceable. Replace unit or return to Lenze service for repair.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze 13466006 inverter?

Parameters can be transferred by removing the pluggable E84AYM20 memory module from the existing drive and inserting it directly into the replacement E84AVBDE3712SX0 unit. No software or programming cable is required for this transfer.

What software and adapter are required to configure the E84AVBDE3712SX0?

The drive is configured using Lenze EASY Starter commissioning software connected via the X400 diagnostic port using an E84AYCCA USB diagnostic adapter, or directly via an optional handheld keypad.

How is the CANopen node address set on the Lenze 13466006 drive?

The CANopen node address and baud rate are set using hardware DIP switches located directly on the drive.

What causes fault code 0x0011 (OC1) and how is it resolved?

Fault 0x0011 indicates an output short circuit or earth fault. Check the motor windings and power cabling for short circuits. If the fault persists with the motor cable disconnected, internal power module damage is present requiring drive repair or replacement.

What does a solid red DRIVE-ERR LED indicate on the inverter?

A solid red DRIVE-ERR LED indicates an active fault condition that has inhibited drive operation. If this state persists after cycling input power, an internal hardware failure is indicated.

Is there a recommended modern successor for the Lenze 8400 BaseLine series?

Yes, the Lenze i550 series cabinet frequency inverters are recommended as the modern successor line for new designs or full system retrofits.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.