Lenze 15842826 E84AVSCE3714SX0 – 8400 StateLine C Frequency Inverter 0.37kW

New 
On request
Refurbished   
10+ available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8400 | Series: 8400 StateLine C

The Lenze 15842826, type E84AVSCE3714SX0, is a compact IP20 panel-mounted frequency inverter within the Lenze 8400 StateLine C series. Designed for precise motor speed regulation and motion control in automated machinery, this drive provides a rated power output of 0.37 kW (0.5 hp) and a continuous output current of 1.3 A. Operating from a 3-phase AC input supply ranging between 320 V AC and 528 V AC at 45 to 65 Hz, it manages 3-phase AC motors through Sensorless Vector Control (SLVC) or configurable V/f characteristic curves. With output frequencies up to 599 Hz and peak current capabilities up to 1.95 A, this unit is routinely deployed in packaging equipment, conveyor systems, industrial fans, and processing machinery.

Network integration is established via an onboard CANopen system bus capable of data transmission up to 1000 kbps, complemented by a modular expansion slot for optional fieldbus interface modules such as PROFINET, PROFIBUS, EtherCAT, or EtherNet/IP. Functional safety is built directly into the drive terminals through dual-channel Safe Torque Off (STO) compliant with SIL 3 (EN IEC 62061) and PL e (EN ISO 13849-1), eliminating the requirement for external power contactors. Commissioning a replacement unit is straightforward thanks to the pluggable EEPROM memory chip (E84AYM100). By swapping the memory card into a spare drive, parameter sets and application configurations are instantly moved without requiring a PC or software tools, with ABC Industrial Parts supplying tested spare units and parameter handling support for rapid replacement.

Real-time operational status is displayed through front diagnostic LEDs including DRV-READY, DRV-BUSY, DRV-ERR, CAN-RUN, and CAN-ERR. When drive trips occur, fault information is stored in the internal diagnostic buffer and accessed via software tools like Lenze EASY Starter or the optional X400 keypad. Initial field checks should cover input supply voltage, motor cable integrity, CAN bus 120 Ohm termination resistors, and the 24 V DC supply across safety terminals SIA and SIB. If a persistent internal hardware failure such as error H05 occurs, internal component repair is not field-serviceable, making drive replacement or exchange through ABC Industrial Parts the most practical solution to restore operation.

Technical Specifications

Rated Power0.37 kW (0.5 hp)
Supply Voltage Range320 - 528 V AC
Nominal Supply Voltage3-phase 400/480 V AC
Supply Frequency45 - 65 Hz
Rated Input Current1.3 A
Continuous Output Current1.3 A
Peak Output Current1.95 A
Output Frequency Range0 - 599 Hz
Switching Frequency8 kHz
Control MethodSensorless Vector Control (SLVC), V/f Characteristic Control
Integrated Bus InterfaceCANopen / System Bus
Protection RatingIP20
Mounting TypeCabinet / Panel Mount
Digital I/O Channels5 Inputs / 1 Output
Analog I/O Channels1 Input / 1 Output
Functional Safety LevelSafe Torque Off (STO) EN ISO 13849-1 PL e / SIL 3

Programming and Configuration

Parameter adjustments and programming for the Lenze E84AVSCE3714SX0 inverter are executed using Lenze EASY Starter or Lenze Engineer software. Online connection to a PC requires the optional Lenze USB Diagnostic Adapter (E84AVZCU000) or direct mounting of the pluggable Lenze X400 Keypad (E84AVZKE000) onto the drive's diagnostic port. The engineering interface grants full configuration access to motor dynamics, switching frequency settings up to 16 kHz, acceleration and deceleration ramps, and real-time monitoring registers.

Application data and drive parameters are stored entirely on the pluggable Lenze memory chip (E84AYM100). During maintenance or hardware replacement, this chip can be removed from the original unit and inserted into the replacement inverter. This tool-free parameter swap reinstates complete drive configuration without requiring engineering software, parameter re-entry, or re-commissioning of motor constants.

Communication and System Integration

The Lenze 15842826 frequency inverter incorporates an onboard CANopen system bus interface operating at transfer rates up to 1000 kbps. It supports process data objects (PDO) and network synchronization commands, allowing immediate connectivity with CANopen master controllers. Reliable network communication requires correct node ID allocation, matching bus transmission speeds, and proper 120 Ohm termination resistors installed at both physical ends of the network line.

For integration into other fieldbus networks, the 8400 StateLine C architecture includes an extension slot for option modules. Compatible communication modules include PROFIBUS-DP (E84AYCPM), PROFINET (E84AYCER), EtherCAT (E84AYCET), EtherNet/IP (E84AYCEO), and Modbus RTU. This modular design permits flexible integration into multi-vendor industrial networks without replacing the underlying drive platform.

Diagnostics and Status Indication

Diagnostic indicators on the front panel provide visual status updates regarding operational state and communication health. Additional diagnostic evaluation is accessible online through Lenze EASY Starter software, the X400 Keypad, or CANopen status registers, all of which query the drive's fault history buffer.

When a trip condition occurs, the red DRV-ERR LED signals an active warning or fault. Persistent internal failures trigger error registers that specify electrical, thermal, or bus fault conditions.

Status LED Indicators

LEDColor/StatusMeaning
DRV-READYGreen - SolidDrive is ready for operation / operational state.
DRV-BUSYYellow - SolidDrive is running / processing command.
DRV-ERRRed - Solid / FlashingFault or error state active. Red flashing indicates warning or trip condition. Persistent internal error state indicates hardware failure requiring repair/replacement.
CAN-RUNGreen - SolidCANopen bus operational status.
CAN-ERRRed - Solid / FlashingCANopen bus error / bus off condition.

Replacement and Spare Part Considerations

Before replacing a Lenze 15842826 (E84AVSCE3714SX0) inverter, confirm that the power rating (0.37 kW), voltage specification (3-phase 320–528 V AC), and physical mounting dimensions match the existing panel layout. If optional fieldbus cards such as PROFIBUS or PROFINET are installed on the original drive, transfer these expansion modules to the replacement unit prior to power-up.

Parameter setup on the replacement drive can be achieved instantly by transferring the removable EEPROM memory chip (E84AYM100) from the old unit into the spare. Ensure that safety input terminals SIA and SIB receive the required 24 V DC power supply for the dual-channel STO circuit. For facilities migrating away from the 8400 StateLine C family, the recommended successor series is the Lenze i550 cabinet frequency inverter.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
LUUndervoltage DC BusDC-bus voltage fell below minimum allowable threshold.Mains supply voltage too low or mains failure.Check mains input voltage and power supply connection.
OUOvervoltage DC BusDC-bus voltage exceeded maximum allowable threshold.Overhauling motor load during deceleration; deceleration time too short.Extend deceleration time or connect braking resistor / check internal brake transistor.
OC1Short Circuit / OvercurrentExcessive instantaneous output current detected.Short circuit or ground fault at motor cables or motor terminals; acceleration ramp too steep.Check motor and motor wiring for short circuits and insulation faults; increase acceleration time.
OC5I x t Motor OverloadDrive or motor overload thermal model trip.Continuous overload or motor operating beyond continuous current limit.Reduce mechanical load on motor or check motor power sizing.
OHHeatsink OvertemperatureHeatsink temperature threshold exceeded.Insufficient cooling airflow, high ambient temperature, or dirty heatsink fins.Clean heatsink, ensure adequate cabinet ventilation and ambient temperature limits.
OH4Motor OvertemperatureMotor temperature sensor trip.Motor overheating detected via PTC thermistor or thermal contact switch.Allow motor to cool down, inspect motor cooling fan, check load.
CE0Communication Error CANopenCANopen communication interruption or bus-off event.Cable fault, incorrect baud rate, broken line, or missing bus termination resistor.Check CAN cabling, termination resistors (120 Ohm), and node ID settings.
CE1Process Data Monitoring Time OutProcess data object (PDO) transmission time limit exceeded.Master controller stopped sending process data or cyclic interval timeout.Check master controller status, fieldbus cycle time, and wiring.
STOSafe Torque Off Active / FaultSafety input circuit interrupted or STO switching error.Safety inputs SIA/SIB disabled or channel discrepancy detected.Check 24 V DC supply to safety input terminals SIA/SIB and safety relay function.
H05Internal Hardware ErrorInternal hardware self-test failure.Internal electronic component failure or corrupted internal EEPROM.Internal hardware fault — power cycle drive; if fault persists, return unit for repair or replace inverter.

Frequently Asked Questions

How do I transfer parameters to a replacement Lenze 15842826 inverter?

Parameters can be transferred instantly by removing the pluggable Lenze memory chip (E84AYM100) from the original inverter and inserting it into the replacement drive. Alternatively, parameter sets can be transferred using Lenze EASY Starter software via a USB diagnostic adapter or configured manually with the X400 keypad.

What network interfaces come integrated on the E84AVSCE3714SX0?

The drive includes an onboard CANopen system bus interface supporting transfer rates up to 1000 kbps. An internal extension slot allows additional communication modules to be installed for PROFINET, PROFIBUS, EtherCAT, or EtherNet/IP.

What does fault code H05 mean on this drive?

Fault code H05 indicates an internal hardware self-test failure or internal EEPROM corruption. If cycling the input power does not clear the error, internal electronic component damage has occurred and the unit requires repair or replacement.

Does this frequency inverter include integrated safety functions?

Yes, it features dual-channel Safe Torque Off (STO) certified to SIL 3 (EN IEC 62061) and PL e (EN ISO 13849-1), providing functional safety without needing external line contactors.

What is the recommended migration successor for the 8400 StateLine C series?

The recommended successor series for cabinet-mounted 8400 StateLine C frequency inverters is the Lenze i550 cabinet inverter series.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.