Lenze E84AVHCE2222SB0 8400 Highline C Frequency Inverter 2.2 kW

New 
On request
Refurbished   
1 available for direct collection
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: Inverter Drives 8400 | Series: 8400 Highline C

The Lenze E84AVHCE2222SB0 is a 2.2 kW cabinet-mounted frequency inverter belonging to the 8400 Highline C series within the Lenze Inverter Drives 8400 family. Designed for precise motion tasks and dynamic drive applications, this unit operates across an input voltage range of 180 to 264 V AC on a 230 V or 240 V AC nominal mains supply. It draws a rated input current of 18 A and delivers a continuous output current of 9.5 A with an output frequency range of 0 to 599 Hz. Integrated hardware features include a Class B RFI filter for electromagnetic compliance, an internal braking chopper for dynamic braking, and Safe Torque Off (STO) functional safety. Drive performance supports V/f characteristic control, sensorless vector control (SLVC), and servo control for asynchronous motors (SC-ASM), along with integrated point-to-point positioning and synchronized motion control.

Control wiring connects directly to 8 digital inputs, 3 digital outputs, 2 configurable analog inputs, and 2 analog outputs. The drive incorporates an onboard CANopen system bus interface alongside a dedicated extension slot for optional fieldbus communication modules, such as the PROFINET module (E84AYCPM), PROFIBUS-DP, EtherCAT, or EtherNet/IP. Putting a replacement drive into service does not require complex PC tools, as parameter configurations are stored on a plug-in Lenze E84AYM series memory module. Transferring the existing memory card into a spare unit allows immediate tool-free parameter restoration. For complete drive diagnostics, parameter tuning, or custom block programming, ABC Industrial Parts supports engineering tasks using Lenze L-force EASY Starter or L-force Engineer Highline software, as well as the plug-in Lenze Keypad X400 (E84AYKCE).

Operational statuses and diagnostics are indicated on the unit via multi-color status LEDs for DRV-READY/DRV-ERR, CAN-RUN, and CAN-ERR. Additional diagnostic logging is accessible through software, keypad buffers, or fieldbus registers to track fault conditions such as motor overcurrent (OC1), DC bus overvoltage (OU), DC bus undervoltage (LU), or thermal trips (OH, OH4, OH7). First-line troubleshooting should include verifying input line voltages, motor insulation, braking resistor connections, and the 24 V STO enable circuit. When persistent fault codes like memory card error (EE) point to underlying power section or internal board failures that cannot be serviced in the field, sourcing a tested replacement unit or utilizing repair services through ABC Industrial Parts provides a rapid return to operation.

Technical Specifications

ManufacturerLenze
Part NumberE84AVHCE2222SB0
Model / Type8400 Highline C
Component TypeFrequency Inverter
Product FamilyInverter Drives 8400
Rated Power2.2 kW
Nominal Mains Supply Voltage230 / 240 V AC
Supply Voltage Range180 - 264 V AC
Rated Input Current18 A
Continuous Output Current9.5 A
Output Voltage Range0 - 230 V AC
Output Frequency Range0 - 599 Hz
Default Switching Frequency8 kHz
Control ModesV/f control, Sensorless Vector Control (SLVC), Servo Control (SC-ASM)
Integrated Safety FunctionSafe Torque Off (STO)
Integrated RFI FilterClass B
Braking ChopperIntegrated
Onboard Fieldbus InterfaceCANopen
Digital I/O Channels8 Digital Inputs / 3 Digital Outputs
Analog I/O Channels2 Analog Inputs / 2 Analog Outputs
Mounting StyleCabinet Installation

Programming and Configuration

Engineering and commissioning of the Lenze E84AVHCE2222SB0 frequency inverter are supported via Lenze L-force EASY Starter software for standard service tasks and Lenze L-force Engineer Highline software for advanced motion control, point-to-point positioning, and function block customization. Operating modes can be configured for V/f characteristic control, sensorless vector control (SLVC), or servo control for asynchronous motors (SC-ASM).

Parameter management is simplified through the use of plug-in Lenze E84AYM series memory modules. Storing the entire drive configuration on removable hardware allows technicians to swap parameters to a spare unit without connecting a PC. Direct local parameterization, status monitoring, and fault memory inspection can also be conducted using the optional Lenze Keypad X400 (E84AYKCE).

Communication and System Integration

The E84AVHCE2222SB0 inverter features an integrated CANopen system bus interface for direct communication within network architectures. Physical control wiring is accommodated via 8 digital inputs, 3 digital outputs, 2 analog inputs, and 2 analog outputs, providing direct connectivity for sensors, control signals, and feedback elements.

System expansion is provided by an extension slot designed for plug-in fieldbus modules. Supported communication extensions include the PROFINET module (E84AYCPM), PROFIBUS-DP, EtherCAT, and EtherNet/IP. These interfaces allow the drive to communicate operational data, status parameters, and diagnostic registers directly to higher-level PLC control systems.

Diagnostics and Status Indication

Visual operational status for the Lenze E84AVHCE2222SB0 is provided via three multi-color LEDs located on the drive front panel. These LEDs indicate drive enable status, controller inhibit, active warnings, internal faults, and CANopen network operational states.

In addition to real-time LED indication, detailed error history and status data can be read through the diagnostic memory buffer using Lenze keypad units or engineering software, as well as via fieldbus diagnostic registers.

Status LED Indicators

LEDColor/StatusMeaning
DRV-READY / DRV-ERRGreen / Red - Solid / FlashingGreen steady = Drive ready / operational; Flashing green = Controller inhibit / STO active; Flashing red = Warning active; Solid red = Fault / error active.
CAN-RUNGreen - Solid / FlashingGreen LED indicating CANopen node status: Pre-operational (blinking), Operational (solid green), or Stopped (single flash).
CAN-ERRRed - Solid / Flashing / OffRed LED indicating CANopen bus condition: Off = No error; Single flash = Warning level reached; Double flash = Guard event / Heartbeat fault; Solid red = Bus Off condition.

Replacement and Spare Part Considerations

When selecting a spare unit for the Lenze E84AVHCE2222SB0, ensure the replacement matches the full part number, confirming the 2.2 kW power rating, 230 V AC supply specification, integrated Class B filter, internal brake chopper, and Safe Torque Off functionality.

Commissioning a replacement drive requires transferring the non-volatile parameter memory module (Lenze E84AYM series) from the original unit to the replacement hardware. The new drive reads the stored configuration automatically upon startup, eliminating the need to recreate parameter sets using PC software. If optional communication modules like the PROFINET module (E84AYCPM) are present, transfer them to the new drive and confirm fieldbus address settings.

Before applying mains voltage, inspect terminal connections for power lines, motor phases, braking resistors, and the 24 V STO safety circuit. Persistent errors unaffected by memory module swaps indicate internal power section or control board failures that require full drive replacement.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
OC1Motor OvercurrentShort circuit or overcurrent detected on output terminals.Short circuit in motor winding or cable, phase-to-ground fault, acceleration time too short.Check motor wiring and insulation, verify motor parameter configuration, increase acceleration time.
OUDC Bus OvervoltageDC bus link voltage exceeded the upper trip limit.Excessive braking energy regenerated into DC link, deceleration ramp too steep, brake chopper circuit or resistor disconnected.Extend deceleration time, check braking resistor connection and value.
LUDC Bus UndervoltageDC link voltage fell below minimum allowable operating threshold.Mains supply power loss, brownout, blown input fuse, phase imbalance.Check input AC supply voltage, input wiring, and mains supply protection.
OHHeatsink OvertemperaturePower section heatsink temperature exceeded maximum threshold.Inadequate air circulation, cooling fan failed or obstructed, continuous overload operation.Clean cooling fins, check control cabinet ventilation and internal fan operation, reduce motor load.
OH4Motor Thermal Sensor FaultMotor temperature switch or thermistor triggered overtemperature trip.Motor thermal overload, cooling fan failure on motor, open sensor wire.Allow motor to cool down, inspect motor cooling, verify PTC/TP sensor connection.
OH7Motor I2t OverloadCalculated motor thermal load model reached 100%.Continuous operation at low speed with high load, incorrect rated motor current parameter.Check motor sizing and continuous current settings in parameter set.
EEMemory Module ErrorError reading or writing data from/to the plug-in memory card.Memory card missing, damaged, unformatted, or internal EEPROM hardware fault.Re-insert memory module, replace memory card. If fault persists across multiple cards, internal drive hardware failure requiring unit replacement.
CCECommunication FaultCommunication lost on integrated CANopen or optional extension fieldbus module.Disconnected bus cable, incorrect bus baud rate or node address, master PLC offline.Check communication cabling, line termination resistors, fieldbus configuration, and PLC state.
IMPPulse Inhibit / STO TriggeredSafe Torque Off active or controller enable missing during active run command.Safety interlock open, emergency stop button pressed, safety circuit wiring fault.Check safety circuit wiring, reset emergency switch, verify 24 V STO enable signal.

Frequently Asked Questions

How do I transfer parameter configurations to a replacement drive?

Parameters can be transferred by moving the plug-in Lenze E84AYM memory module from the original drive into the replacement unit. Upon powering up, the spare drive automatically loads the complete parameter profile without requiring PC engineering tools.

Which software packages are compatible with the Lenze E84AVHCE2222SB0?

The drive is compatible with Lenze L-force EASY Starter for routine servicing and commissioning, as well as Lenze L-force Engineer Highline for motion control setup, positioning tasks, and function block programming.

What causes the IMP fault code on this inverter?

The IMP code indicates a Pulse Inhibit or STO Triggered status. This condition occurs when the Safe Torque Off circuit is active or when the 24 V controller enable signal is absent during a run command. Check safety circuit interlocks and cabling.

What optional fieldbus modules can be installed on this unit?

In addition to the built-in CANopen interface, the extension slot accepts optional modules including PROFINET (E84AYCPM), PROFIBUS-DP, EtherCAT, and EtherNet/IP.

What action should be taken if the drive displays an EE fault code?

The EE code indicates a Memory Module Error. Remove and re-seat the E84AYM memory card, or install a replacement card. If the error remains active across multiple memory cards, the internal EEPROM hardware has failed and the drive unit must be replaced.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.