Lenze 13010331 E82ZAFPC010 8200 Vector PROFIBUS-DP Module

New 
On request
Refurbished   
1 available for direct collection
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector

The Lenze E82ZAFPC010, part number 13010331, is a PROFIBUS-DP communication module designed for the Lenze 8200 vector product family, including 8200 vector and 8200 motec frequency inverters. Operating directly within the host inverter's integrated Function Module (FIF) slot, this compact unit acts as a fieldbus slave node that enables centralized PLC parameter access, remote speed profiling, and real-time process data exchange. The module draws its required 5 V DC operational power internally from the host drive's FIF system connector and features a standard 9-pin Sub-D female interface for external fieldbus connection.

Integrating the E82ZAFPC010 into a PROFIBUS network requires aligning the hardware and software configuration with the master controller, such as a Siemens S7-300, S7-400, S7-1200, or S7-1500 PLC using GSD files Len0418.gsd or Len082.gsd. Node addressing between 1 and 126 is set either using the 7-position hardware DIP switches on the front face or via drive parameter C1809 using Lenze Global Drive Control (GDC) software or the E82ZBC Keypad Operating Module. Commissioning is streamlined by automatic baud rate detection across the full range from 9.6 kbit/s up to 12 Mbit/s. When installing a replacement module, matching the node address to the original network layout ensures immediate communication recovery, and ABC Industrial Parts can support technical teams requiring tested replacement units or parameter configuration guidance.

Visual diagnostics on the front face of the E82ZAFPC010 are provided by two LEDs: a green RUN / READY light indicating logic power and system initialization, and a red BUS ERROR / FAULT indicator signaling bus line interruptions or configuration mismatches. Additional diagnostic data can be retrieved from drive parameter C0150 or via PLC diagnostic telegrams. Field troubleshooting for common trips like CE0, CE1, or AOT involves checking the physical 9-pin connector, verifying line termination resistors, confirming master status, and inspecting contact pins in the FIF slot. If the module reports a persistent internal communication trip such as CE3 despite clean contacts and proper seating, internal hardware damage is indicated, in which case replacing the module or sourcing a tested exchange drive through ABC Industrial Parts provides a direct route to restoring production.

Technical Specifications

ManufacturerLenze
Part Number13010331
Model / TypeE82ZAFPC010
Product Family8200 vector
Component TypePROFIBUS-DP Communication Module
Communication InterfacePROFIBUS-DP (RS-485)
Protocol VersionDP-V0 / DP-V1 Slave
Baud Rate Range9.6 kbit/s - 12 Mbit/s (Auto-detection)
Bus Address Range1 - 126
Supply Voltage5 V DC (Internal via FIF Slot)
Fieldbus Connector9-pin Sub-D female
Host InterfaceFIF Slot (Multi-pin system connector)

Programming and Configuration

Configuration and parameterization of the Lenze E82ZAFPC010 module can be executed through Lenze Global Drive Control (GDC) software or via the local E82ZBC Keypad Operating Module connected to the host drive. These engineering interfaces grant direct access to drive-level monitoring parameters such as C0150 as well as fieldbus configuration registers.

Station address assignment for PROFIBUS DP-V0/DP-V1 slave operation is determined by either the hardware 7-position DIP switches on the front panel or software parameter C1809. When parameter-based addressing is selected, setting changes must be saved to the non-volatile memory of the host frequency inverter to ensure address settings persist after power cycles.

For master-side PLC engineering, system integration requires importing the corresponding GSD file—typically Len0418.gsd or Len082.gsd—into the PLC configuration environment. This file defines the input and output process data word allocations, baud rate support up to 12 Mbit/s, and diagnostic structures needed by the host controller.

Communication and System Integration

The E82ZAFPC010 provides an RS-485 PROFIBUS-DP interface via a front-facing 9-pin Sub-D female connector. Designed in compliance with EN 50170 and IEC 61158 standards, the module functions as a DP-V0 / DP-V1 slave node that interfaces with main control systems in automated material handling, packaging, automotive, and assembly lines.

Network speed adaptation is fully automated across supported baud rates from 9.6 kbit/s to 12 Mbit/s. The automatic baud rate detection mechanism eliminates manual baud rate selection, enabling the module to synchronize instantly with the active PROFIBUS master scan cycle.

Physical network setup requires proper line termination at both end nodes of the PROFIBUS segment. The 9-pin Sub-D connector connects directly to standard bus connectors with built-in terminating resistors, ensuring noise-immune serial communication over the RS-485 bus lines under industrial operating conditions.

Diagnostics and Status Indication

Diagnostic monitoring for the E82ZAFPC010 relies on a combination of front-panel LED indicators, host inverter diagnostic parameters, and PROFIBUS slave status frames sent to the master PLC. The green RUN / READY LED illuminates solid when the 5 V DC internal supply is healthy and internal initialization completes, while the red BUS ERROR / FAULT LED illuminates or flashes during communication interruptions, configuration mismatches, or master telegram losses.

In addition to visual LED states, technicians can access detailed fieldbus status codes directly through the drive display or Lenze Global Drive Control software via parameter C0150. Master PLCs also receive standard DP slave diagnostic messages when bus line or data transfer faults occur.

Status LED Indicators

LEDColor/StatusMeaning
BUS ERROR / FAULTRed - Flashing or Solid OnPROFIBUS communication error, configuration error, or loss of telegrams from master. Off when bus communication operates normally.
RUN / READYGreen - Solid OnModule power supply OK and internal initialization complete. Off when module is unpowered or has an internal hardware error.

Replacement and Spare Part Considerations

When replacing an existing Lenze E82ZAFPC010 module in a Lenze 8200 vector or 8200 motec inverter (0.25 kW to 90 kW), first isolate electrical power to the host drive. Inspect the multi-pin FIF slot connector on the inverter board to ensure pins are clean and undamaged before inserting the spare module firmly into place.

Verify that the station address on the replacement module matches the original unit's address setting. If address selection was configured via DIP switches, duplicate the 7-position switch settings on the replacement unit prior to installation. If addressing was assigned via software, parameter C1809 must be configured using Global Drive Control software or the E82ZBC Keypad Module.

Because the module features automatic baud rate detection, no software baud adjustments are necessary. Once powered, confirm that the green RUN / READY LED remains solid green and the red BUS ERROR / FAULT LED turns off once the PROFIBUS master establishes communication.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0Communication Error 0 / Time-OutCommunication failure between function module (FIF slot) and host drive controller or fieldbus line interruption.Fieldbus cable disconnected, PROFIBUS master stopped, baud rate mismatch, or improper module insertion.Check cable connection, verify termination resistors, confirm master status, re-seat module in FIF slot.
CE1Communication Time-Out Process DataProcess data transfer timeout between PROFIBUS master and host frequency inverter.PLC in STOP mode, fieldbus telegram interruption, watch-dog timer expired.Verify PLC program status, inspect bus cabling for EMC interference, verify bus cycle timing settings.
CE3INTERN COMM ERRORInternal communication failure between the host inverter control board and the E82ZAFPC010 module.Module defective, dirty contact pins, or internal hardware error on function module or host drive.Power cycle host drive. Clean contacts and re-insert module firmly. If fault persists, replace the communication module; if still unrectified, return host drive for repair.
AOTAlarm Fieldbus TimeoutFieldbus watchdog elapsed while configured for alarm reaction instead of fault shutdown.Temporary network loss or master processing delay.Inspect physical fieldbus wiring, check master bus cycle, verify termination active at line ends.

Frequently Asked Questions

How is the station address configured on the Lenze E82ZAFPC010 module?

The station address (1 to 126) can be configured either using the 7-position hardware DIP switches located on the module face or electronically through parameter C1809 using Lenze Global Drive Control (GDC) software or an E82ZBC Keypad Operating Module.

Does the Lenze E82ZAFPC010 require manual baud rate configuration?

No, the E82ZAFPC010 features automatic baud rate detection across the full PROFIBUS DP spectrum from 9.6 kbit/s up to 12 Mbit/s, enabling automatic synchronization with the bus master.

Which Lenze drive series are compatible with the E82ZAFPC010 PROFIBUS module?

The module is designed for direct installation into the integrated Function Module (FIF) slot of Lenze 8200 vector frequency inverters (0.25 kW to 90 kW) and Lenze 8200 motec frequency inverters.

What do the RUN and BUS ERROR LEDs indicate on the front panel?

The green RUN / READY LED indicates that the 5 V DC logic power is healthy and system initialization is complete. The red BUS ERROR / FAULT LED indicates PROFIBUS communication loss, configuration mismatches, or missing master telegrams, turning off under normal bus operation.

Which GSD files are required to integrate the E82ZAFPC010 into a Siemens PLC?

Integration into PROFIBUS masters such as Siemens S7-300, S7-400, S7-1200, or S7-1500 controllers utilizes GSD files Len0418.gsd or Len082.gsd.

How do I resolve a CE3 internal communication fault code?

A CE3 code indicates internal communication failure between the host drive and module. Power cycle the drive, clean the FIF slot contact pins, and re-seat the module firmly. If the fault persists, replace the communication module or inspect the host drive control board.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.