Product Information

Product Family: 8200 Series | Series: 8200 Vector / Motec

The Lenze 13025654 (model E82ZMFBC001) is a CANopen system bus communication module engineered for fieldbus integration of Lenze 8200 vector and 8200 motec frequency inverters. Operating within the Lenze 8200 series, this option card fits directly into the drive's function module slot (FIF) via an internal multi-pin header connection. It establishes an ISO 11898-compliant CANopen interface using a standard 9-pin male Sub-D connector, enabling distributed speed control, torque control, and real-time parameter monitoring across automated production networks such as conveyor systems, packaging lines, and material handling applications.

Putting a replacement E82ZMFBC001 module into service requires matching network transmission speeds and node address settings to the existing control architecture. The module supports baud rates ranging from 10 kbit/s up to 1000 kbit/s (1 Mbit/s) and node addresses from 1 to 63, configured either through onboard DIP switches (S1 and S2) or drive parameter C0359. Integrated, switchable 120 Ohm bus termination resistors eliminate the need for external terminating components at network ends. Network parameters and drive configurations can be backed up and restored using Lenze Global Drive Control (GDC) software, an E82ZBC XT Keypad, or a PC system bus adapter such as the EMF2173IB or EMF2177IB, with additional configuration data retained in the inverter's internal EEPROM. Technical support and pre-configured spares from ABC Industrial Parts can help ensure smooth parameter transfer and fast commissioning.

Diagnostic monitoring is provided through onboard LEDs and dedicated drive parameters. The CAN-RUN LED indicates reset, pre-operational, or operational states, while the CAN-ERR LED highlights warning limits, guarding or heartbeat errors, or bus-off states. Detailed diagnostic information is logged in CAN status registers C0361 through C0364 and displayed as fault codes on connected keypads or software. Messages such as CE0 through CE3 point to cabling, termination, node guarding, or SDO parameter transfer issues, whereas fault code EEr indicates an external option module communication failure caused by improper seating in the FIF slot or an internal module fault. If re-seating the card does not resolve the fault, an internal transceiver or board hardware failure is indicated, making module replacement or repair through ABC Industrial Parts the most effective path to restoring machine uptime.

Technical Specifications

ManufacturerLenze
Part Number13025654
Model / TypeE82ZMFBC001
Product Family8200 Series
Component TypeCommunication Module
Communication StandardCANopen / ISO 11898
Protocol ProfileCANopen DS301 (Slave)
Supported Baud Rates10, 20, 50, 125, 250, 500, 800, 1000 kbit/s
Node Address Range1 to 63
Bus Termination120 Ohm (Switchable)
Fieldbus ConnectorSub-D 9-pin (Male)
Backplane InterfaceInternal Multi-pin Header (FIF Slot)
Configuration StorageInverter EEPROM and DIP Switches

Programming and Configuration

The E82ZMFBC001 CANopen module utilizes dual setup mechanisms combining hardware controls and software parameters. Operating parameter configurations are stored within the host Lenze 8200 inverter's internal EEPROM, while hardware DIP switches S1 and S2 on the module allow direct physical assignment of network node addresses from 1 to 63 and network baud rates. Alternatively, node addresses can be assigned through software parameter C0359.

System integration, parameter monitoring, and backup routines are performed using Lenze Global Drive Control (GDC) software connected via an EMF2173IB or EMF2177IB PC system bus adapter. For direct machine-side commissioning, an E82ZBC XT Keypad can be connected directly to the inverter. These interfaces allow maintenance staff to inspect parameter status registers C0361 through C0364, manage SDO object accesses, and adjust drive parameters across the CANopen fieldbus network.

Communication and System Integration

Designed in accordance with ISO 11898 specifications and the CANopen DS301 slave profile, the E82ZMFBC001 provides continuous real-time fieldbus communication between Lenze frequency inverters and primary network controllers. The physical fieldbus connection is made via a standard 9-pin male Sub-D connector, while internal signals and power pass through a multi-pin header that plugs into the drive's function module slot (FIF).

The interface supports standard fieldbus transmission speeds of 10, 20, 50, 125, 250, 500, 800, and 1000 kbit/s across node address range 1 to 63. To simplify field cabling and eliminate line reflections at network boundaries, the module incorporates switchable 120 Ohm bus termination resistors directly on the board.

Diagnostics and Status Indication

Visual status monitoring is provided by two LEDs on the front of the module: a green CAN-RUN indicator and a red CAN-ERR indicator. These LEDs convey current operational modes, network activity, bus errors, or hardware resets. Detailed diagnostic codes are simultaneously recorded in drive parameters C0361 through C0364, accessible using either the E82ZBC XT Keypad or Global Drive Control (GDC) software.

Status LED Indicators

LEDColor/StatusMeaning
CAN-RUNGreen - Off / Blinking / SolidOff = Reset / Stopped / No Power; Blinking = Pre-Operational state; Solid = Operational state
CAN-ERRRed - Off / Single Flash / Double Flash / SolidOff = No error; Single Flash = Warning limit reached; Double Flash = Guarding/Heartbeat error; Solid = Bus Off state or hardware failure

Replacement and Spare Part Considerations

When installing a replacement E82ZMFBC001 module, always disconnect power from the drive before seating the module into the function module slot (FIF). Check that the module pins align correctly with the internal backplane header to prevent physical damage or loose electrical connections.

Before restoring power, mirror the node address DIP switches (S1 and S2) and termination settings from the original card, or verify software parameter C0359 in the host drive. If fault code EEr persists after re-seating and cycle powering the unit, the module has suffered an internal transceiver or hardware board fault and must be replaced.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0CAN Communication Error / TimeoutCommunication interruption or timeout on the CAN bus interface.Broken CAN cable, incorrect baud rate, wrong node address, missing network termination resistors.Check CAN line cabling, verify termination resistance (120 Ohm at network ends), confirm matching baud rates across all nodes.
CE1CAN Bus Off / Bus ErrorThe CAN controller has entered the Bus-Off state due to excessive error counts.High EMI noise interference, reversed CAN-H/CAN-L lines, loose connections, defective transceiver hardware.Check cable shielding and grounding, verify line connections, replace module if error persists after wiring check (internal transceiver hardware fault).
CE2CAN Guarding / Heartbeat ErrorNode guarding or heartbeat monitoring signal missed from master.CAN master stopped, network overload, excessive jitter, master cycle time too long.Verify master PLC status, review network load and node guarding time configuration.
CE3CAN SDO / Object Access ErrorFault occurred during parameter data transfer via SDO.Accessing non-existent index/subindex, writing invalid parameter value or read-only parameter.Check CANopen object dictionary mappings and SDO request parameters.
EErExternal Option Module FaultDrive cannot communicate with the plugged-in communication module.Module poorly seated in FIF slot, damaged pin connections, internal module hardware failure.Turn off power, remove and re-seat module in FIF slot. If fault remains, module is defective and requires replacement — internal board failure.

Frequently Asked Questions

How is the node address configured on the Lenze E82ZMFBC001 module?

The node address can be set physically between 1 and 63 using internal hardware DIP switches S1 and S2 on the module, or digitally via drive parameter C0359.

What baud rates are supported by the E82ZMFBC001 CANopen module?

The module supports transmission speeds of 10, 20, 50, 125, 250, 500, 800, and 1000 kbit/s.

Does the E82ZMFBC001 require external bus termination resistors?

No external termination resistors are required. The module includes integrated 120 Ohm termination resistors that can be activated via onboard switches at network endpoints.

What does fault code EEr mean on a Lenze 8200 series drive?

Fault code EEr indicates an external option module fault where the drive cannot communicate with the plugged-in E82ZMFBC001. This is typically caused by improper seating in the FIF slot, bent pins, or an internal hardware failure on the communication board.

Which software tools can be used to monitor and configure the E82ZMFBC001?

Configuration and diagnostic monitoring can be performed using Lenze Global Drive Control (GDC) software connected via an EMF2173IB or EMF2177IB PC system bus adapter, or locally using an E82ZBC XT Keypad.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.