Lenze 13013153 EMF2175IB PROFIBUS-DP Communication Module

New 
On request
Refurbished   
4 available within 4 - 6 business days
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: 8200 vector / 9300 Series Accessories | Series: 8200 vector / 9300

The Lenze 13013153 EMF2175IB is a fieldbus communication module engineered to integrate Lenze 8200 vector frequency inverters and 9300 servo drives into PROFIBUS-DP networks. Operating as a DP-V0 slave device, this interface card enables real-time cyclic process data exchange between central automation controllers and distributed drive units across industrial machinery. The module snaps directly into the drive host through a built-in Function Module slot (FIF) and draws its required 5 V DC operating voltage internally from the drive, requiring no external power wiring. Network connection is established using a galvanically isolated 9-pin Sub-D female RS-485 connector.

Putting a replacement module into service involves straightforward hardware matching and bus addressing. Bus node addresses from 1 to 126 are set manually using onboard hardware DIP switches, allowing maintenance teams to align a spare unit with the original node address without altering software code. Transmission speeds adapt automatically across the complete spectrum from 9.6 kbit/s up to 12 Mbit/s. Fieldbus parameter mapping and drive parameterization can be performed using Lenze Global Drive Control (GDC) software or a drive keypad terminal. When commissioning a spare unit, obtaining a pre-tested replacement through ABC Industrial Parts ensures simple physical insertion and immediate communication alignment.

Real-time diagnostic verification relies on two LED indicators located on the module front face alongside drive-level status checking. The PR LED communicates internal power supply and initialization state, while the DE LED alerts operators to active bus data exchange, communication timeouts, or offline master states. System trips such as fault codes CE0, CE1, and CE3 indicate specific fieldbus watchdog, cable, or timing interruptions on the network. Internal hardware faults, indicated by code H05, point to non-field-serviceable board errors where sourcing a replacement unit from ABC Industrial Parts provides the fastest route to restoring production.

Technical Specifications

ManufacturerLenze
Part Number13013153
Model / TypeEMF2175IB
Component TypeCommunication Module
Bus SystemPROFIBUS-DP
ProtocolDP-V0 Slave
Fieldbus InterfaceRS-485 (Galvanically Isolated)
Transmission Speed9.6 kbit/s to 12 Mbit/s (Auto-detect)
Node Address Range1 to 126
Connector Type9-pin Sub-D female
Mounting TypeFunction Module Slot (FIF)
Supply Voltage5 V DC

Programming and Configuration

Parameter setting and fieldbus mapping for the Lenze EMF2175IB module are managed through Lenze Global Drive Control (GDC) engineering software or an attached drive keypad terminal. These tools allow engineers to configure process data word structure, monitor cyclic drive values, and set watchdog timeout thresholds.

Station address assignment is handled independently of software programming via onboard hardware DIP switches. Supporting bus addresses from 1 to 126, these switches enable maintenance personnel to match the hardware address of a donor or replacement card prior to installing the unit into the drive slot.

Communication and System Integration

The Lenze 13013153 EMF2175IB provides a galvanically isolated RS-485 physical interface operating as a DP-V0 slave on PROFIBUS-DP fieldbus networks. Network cabling attaches to the module using a standard 9-pin Sub-D female connector, providing signal isolation in noisy industrial environments.

The module features automatic baud rate detection spanning from 9.6 kbit/s to 12 Mbit/s. This auto-baud capability simplifies integration into higher-level PLC architectures, such as Siemens S7-300 or S7-400 systems, without requiring manual baud rate matching during network setup.

Diagnostics and Status Indication

Visual status monitoring on the front panel of the EMF2175IB is provided by two LEDs labeled PR and DE. The PR LED reports module initialization and internal power status, displaying solid green during normal operation. The DE LED indicates PROFIBUS data exchange state, glowing continuous green during active operation and switching to red when a communication time-out or bus error occurs.

In addition to module LEDs, diagnostic status and active trips can be inspected directly via the host drive keypad or GDC parameter interface. Network faults trigger specific trip codes on the drive controller to assist in rapid troubleshooting.

Status LED Indicators

LEDColor/StatusMeaning
PRGreen - Solid / Flashing / OffGreen continuous = Module initialized and power OK; Flashing = Initialization running or internal fault; Off = No power or module defective.
DEGreen / Red - Solid / OffGreen continuous = Active PROFIBUS data exchange; Red continuous = Communication time-out / bus error / master offline; Off = No active data exchange.

Replacement and Spare Part Considerations

When swapping a communication module in a Lenze 8200 vector or 9300 servo drive, ensure that system power is isolated before inserting the card into the Function Module slot (FIF). Set the hardware DIP switches on the new module to match the original station address (1 to 126). Because transmission speed is automatically detected up to 12 Mbit/s, manual baud rate entry is not required.

Verify that RS-485 bus connectors are securely screwed down and that bus termination resistors are correctly engaged at the physical ends of the PROFIBUS segment. If error code H05 appears upon powering up the replacement card, internal component damage is present, requiring module exchange or professional repair.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
CE0Communication Error FIF SlotCommunication failure or time-out between host drive and function module in FIF slot.PROFIBUS connection broken, watchdog timer elapsed, PROFIBUS master stopped, or bad connection in FIF slot.Check PROFIBUS cable and connector, verify master operating state, ensure module is securely seated in FIF slot. If fault persists after replacing cable/module, host drive interface or module hardware may be defective.
CE1Process Data Monitoring Time-outProcess data monitoring time-out on fieldbus interface.PLC/Master stopped sending cyclically updated process data before time-out elapsed.Check PLC program state, PROFIBUS master status, and response time settings in drive parameters.
CE3PROFIBUS Watchdog FaultPROFIBUS DP master interface watchdog time-out.Bus disconnection, electromagnetic interference, or master fault.Check shielding and routing of RS-485 bus cable, verify bus termination resistors at line ends.
H05Internal Hardware ErrorInternal hardware fault detected during initialization or operation on option module slot.Internal board component failure, damaged connector pins, or EEPROM corruption.Internal hardware fault — non-field-serviceable. Replace communication module or return unit for repair.

Frequently Asked Questions

Which drive series are compatible with the Lenze 13013153 EMF2175IB module?

The EMF2175IB module is compatible with Lenze 8200 vector frequency inverters and Lenze 9300 servo drives, plugging directly into the host drive's Function Module slot (FIF).

How is the station address set on the Lenze EMF2175IB?

The station address is set manually between 1 and 126 using hardware DIP switches located directly on the module, requiring no software programming to establish the node ID.

Does the EMF2175IB require manual baud rate configuration?

No, the module features automatic baud rate detection across transmission speeds ranging from 9.6 kbit/s to 12 Mbit/s.

What do the PR and DE LEDs indicate during operation?

The PR LED indicates power supply status and module initialization (solid green when operating normally). The DE LED displays green during active PROFIBUS data exchange and turns continuous red during communication timeouts, bus errors, or master offline conditions.

What action should be taken if drive fault code H05 appears?

Fault code H05 indicates an internal hardware failure, such as damaged board components or connector pins. This error is non-field-serviceable and requires replacing the module or sending it for repair.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.


Disclaimer:
We are not an authorised distributor of Lenze.
Product photos are for illustration purposes only and may differ from the actual product delivered.
Some of the content on this page was created with the help of AI. While we strive to provide accurate and up-to-date information, errors may occur.